SMC Corporation of America
Elite Part Number Search
Search Results "CE1B12-50L-A93L"

to 3 5, 10L range: -1 to 4 25, 50, 100, 200L range: 1300 0x0514 OUT1 uses the unit for accumulated output index value (When unit: "L" is selected) 2 R/W Accumulated output index L S16 0 Y 0 to 5 OUT1 uses the unit for accumulated output set value (When unit: "ft3" is selected) 1 R/W Accumulated output set value ft3 S16 0 Y Setting range 0 to 9 1310 0x051E Setting range 1, 2, 5, 10, 25, 50L

D (mm) (mm) Cylinder model C D Mounting bolt size Cylinder model C D Mounting bolt size CVQM5010 CVQM325 45 M5 x 45L M6 x 60L 60 15 10 45 x 45L x 60L 60 20 15 50 x 50L x 65L 65 25 20 55 x 55L x 70L 70 30 25 60 x 60L x 75L 75 35 30 65 x 65L 12.5 x 80L 80 9 40 35 70 x 70L x 85L 85 45 40 75 x 75L x 90L 90 50 45 80 x 80L x 95L 95 75 50 85 x 85L x 120L 120 -100 75 110 x 110L x 145L 145 CVQM6310

Operating range RB Model C 8 8 8 8 D 50 60 50 60 75 85 75 85 85 95 75 85 95 130 100 130 Mounting bolt M3 x 50l M3 x 60l M3 x 50l M3 x 60l M5 x 75l M5 x 85l M5 x 75l M5 x 85l M5 x 85l M5 x 95l M5 x 75l M5 x 85l M6 x 95l M6 x 130l M8 x 100l M8 x 130l MKB12-10 MKB12-20 MKB16-10 MKB16-20 MKB20-10 MKB20-20 MKB25-10 MKB25-20 MKB32-10 MKB32-20 MKB40-10 MKB40-20 MKB50-20 MKB50-50 MKB63-20 MKB63-50

Mounting: B (Tapped on Both Sides), Bore Size: 12mm, Stroke: 75mm, Cushion: 40~63 Bore-Cushion Both Sides; 12~32 Bore-No Cushion, Connector: Connector, Cable Length: 0.5m, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, 0.5M, Lead Wire or Prewired Connector: L (3m)

Mounting: B (Tapped on Both Sides), Bore Size: 12mm, Stroke: 25mm, Cushion: 40~63 Bore-Cushion Both Sides; 12~32 Bore-No Cushion, Connector: Connector, Cable Length: 0.5m, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, 0.5M, Lead Wire or Prewired Connector: L (3m)

Mounting: B (Tapped on Both Sides), Bore Size: 12mm, Stroke: 50mm, Cushion: 40~63 Bore-Cushion Both Sides; 12~32 Bore-No Cushion, Connector: Connector, Cable Length: 0.5m, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, 0.5M, Lead Wire or Prewired Connector: L (3m)

Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard / With rod detent function, Environment, Applications: Standard, Cushion: Without cushion, Operating Pressure(MPa): 0.07 to 1.0, Specification: -, Auto Switches: A93, Lead Wire Length(m):

Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard / With rod detent function, Environment, Applications: Standard, Cushion: Without cushion, Operating Pressure(MPa): 0.07 to 1.0, Specification: -, Auto Switches: A93, Lead Wire Length(m):

Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard / With rod detent function, Environment, Applications: Standard, Cushion: Without cushion, Operating Pressure(MPa): 0.07 to 1.0, Specification: -, Auto Switches: A93, Lead Wire Length(m):

Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard / With rod detent function, Environment, Applications: Standard, Cushion: Without cushion, Operating Pressure(MPa): 0.07 to 1.0, Specification: -, Auto Switches: A93, Lead Wire Length(m):

Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard / With rod detent function, Environment, Applications: Standard, Cushion: Without cushion, Operating Pressure(MPa): 0.07 to 1.0, Specification: -, Auto Switches: A93, Lead Wire Length(m):

Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard / With rod detent function, Environment, Applications: Standard, Cushion: Without cushion, Operating Pressure(MPa): 0.07 to 1.0, Specification: -, Auto Switches: A93, Lead Wire Length(m):

wire length (m) Load voltage Auto switch model Electrical entry direction Wiring (Output) Special function Electrical entry Indicator light Style 0.5 (Nil) 3 (L) Applicable load AC DC 12V Horizontal 100V 24V Reed switch 2-wire Relay, PLC Grommet Yes A93 12V 3-wire (NPN) M9N 24V Solid state switch Relay, PLC Grommet Yes 12V 2-wire M9B Lead wire symbol 0.5mNil (Example) A93 3mL A93L

Indicator light Special function Electrical entry Wiring (output) Electrical entry direction 0.5 (Nil) 3 (L) 5 (Z) Applicable loads Type DC AC Perpendicular In-line A96 A96V 3 wire (NPN equiv.) 5V IC circuit A96L A96VL Reed switch Solid state switch Yes A93 A93V 100V Grommet A93L A93VL Relay, PLC 2 wire 24V A90 A90V 5V, 12V No 100V or less IC circuit A90L A90VL F9N F9NV