CQSXB00-20D CQSXB00-45D x 65 L x 40 L 65 40 CQSXB00-25D CQSXB00-50D x 70 L x 45 L 70 45 CQSXB00-30D CQSXB25-5D CQ-M5 x 30 L x 50 L 30 50 Mounting bolt CQSXB16-5D CQSXB00-10D x 35 L CQ-M3 x 25 L 35 25 CQSXB00-10D CQSXB00-15D x 40 L x 30 L 40 30 CQSXB00-15D CQSXB00-20D x 45 L x 35 L 45 35 6.5 CQSXB00-20D CQSXB00-25D x 50 L x 40 L 50 40 8.5 CQSXB00-25D CQSXB00-30D x 55 L x 45 L 55 45 CQSXB00
M6X1 4.8 7 MHL2-20D M6X1 7.3 12 MHL2-25D M8X1.25 12 7 MHL2-25D M8X1.25 17.7 16 MHL2-32D M8X1.25 12 11 MHL2-32D M8X1.25 18 16 MHL2-40D M0X1.5 24 12 MHL2-40D M10X1.5 36 20 Nm MHL2-10D M4X0.7 2.1 MHL2-16D M5X0.8 4.3 MHL2-20D M6X1 7.3 MHL2-25D M8X1.25 17.7 6 - 1. 2. 2 <> AS1200-M5AS2200-01 AS1000AS2000 AS1001FAS2051F 7 - 3-5 Nm MHL2-10D M4X0.7 1.4 MHL2-16D M5X0.8 2.8 MHL2-20D M6X1 4.8 MHL2
Internal Circuit ( ): If not applicable for IEC Standard RB Dimensions J D-B53 Reed switch LED D OUT() Blue(Black) OUT(+) Brown (Red) Resistance -X Zener diode 20D-B54 Zener diode Choke coil Resistance Technical Data Reed switch OUT() ~ Blue(Black) OUT(+)~ Brown (Red) LED Surge absorber D-B64 Operation Range ( l Dimension) (mm) Choke coil Bore size 20 Actuator series 50 63 80 100 40 32 25
A C width across flats D Model A B C MHZ2-10D-X46 MHZ2-16D-X46 MHZ2-20D-X46 MHZ2-25D-X46 9 11 4.5 5.2 7.5 13 7 5.8 10 15 7 6 10.7 20 7 6.2 Refer to pages 4 through 7 for the standard type dimensions, which are the same except for those shown above. Reference value to establish criteria for needle adjustment.
10D (M) 15D (M) 15D (M) 20D (M) 20D (M) 25D (M) 25D (M) 30D (M) 30D (M) 7 35D (M) 35D (M) 14.5 40D (M) 40D (M) 45D (M) 45D (M) 50D (M) 50D (M) 75D (M) 75D (M) x 165l 100D (M) 100D (M) M5 x 75l x 80l x 85l CHQB100 10D (M) M10 x 105l x 110l x 115l x 120l x 125l x 130l x 135l x 140l x 145l x 170l CH QB40 5D (M) 15D (M) 10D (M) 20D (M) 15D (M) x 90l x 95l x 100l x 105l x 110l x 115l x 120l x
(M) 15D (M) 25D (M) 20D (M) 30D (M) 25D (M) 10 35D (M) 30D (M) 15.5 40D (M) 35D (M) 45D (M) 40D (M) 50D (M) 45D (M) 75D (M) 50D (M) 100D (M) CHQWB32 5D (M) M10 x 100l x 105l x 110l x 115l x 120l x 125l x 130l x 135l x 140l x 165l x 190l M10 x 105l x 110l x 115l x 120l x 125l x 130l x 135l x 140l x 145l x 170l x 195l CHQWB80 10D (M) 10D (M) 15D (M) 15D (M) 20D (M) 20D (M) 25D (M) 25D (M)
External gripping force Internal gripping force MHS2-16D MHS2-16D 30 Pressure 0.6MPa Pressure 0.6MPa 30 0.5MPa 0.5MPa Gripping force N Gripping force N 20 20 0.4MPa 0.4MPa 0.3MPa 0.3MPa 10 10 0.2MPa 0.2MPa F 0 0 15 20 15 5 5 10 10 20 25 25 30 30 F Gripping point L mm Gripping point L mm MHS2-20D MHS2-20D 60 60 Pressure 0.6MPa Pressure 0.6MPa Gripping force N External gripping Gripping force
As a rule, it should be turned about 90 beyond the point at which tightening can be felt. 0.5 0.2 0.3 MHL2-20D 0.5 0.2 0.2 MHC MHL2-25D 0.2 0.1 0.2 MHL2-32D 0.4 0.4 0.7 MHT MHL2-40D 0.2 0.4 0.7 MHY MHW MRHQ Misc.
) Model Built-in dust proofing mechanism 60 20 40 60 30 60 80 40 80 100 50 100 120 70 120 160 100 160 200 56 78 96 68 110 130 82 142 162 100 182 200 150 198 242 188 246 286 76 118 156 98 170 210 122 222 262 150 282 320 220 318 402 288 406 486 280 345 425 585 795 935 1025 1495 1690 1690 2560 2775 2905 3820 4655 5270 6830 7905 MHL2-10D MHL2-10D1 MHL2-10D2 MHL2-16D MHL2-16D1 MHL2-16D2 MHL2-20D
MHZ2-25D 1 N1 MHZ2-10D MHZ2-16D MHZ2-20D MHZ2-25D Specifications and dimensions other than the above are the same as the basic type (including narrow type).
Clean Room: 11 (Vacuum Suction Type), Magnet: D (Built-in), Mounting Direction: B (Lateral Mounting), Bore: 8mm, Stroke: 20mm
Clean Room: 10 (Relief Type), Magnet: D (Built-in), Mounting Direction: B (Lateral Mounting), Bore: 8mm, Stroke: 20mm
Magnet: D (Built-in Magnet), Mounting Direction: B (Lateral Mounting), Bore Size: 8, Stroke: 20mm, Action: D (Double Acting), Rod End Thread: Rod End Female Thread (w/o Thread for ø4), Auto Switch: F8N--Solid State, Gen Purpose, 3 Wire NPN, Vertical
Magnet: D (Built-in Magnet), Mounting Direction: B (Lateral Mounting), Bore Size: 8, Stroke: 20mm, Action: D (Double Acting), Rod End Thread: Rod End Female Thread (w/o Thread for ø4), Auto Switch: F8P--Solid State, Gen Purpose, 3 Wire PNP, Vertical
Magnet: D (Built-in Magnet), Mounting Direction: B (Lateral Mounting), Bore Size: 8, Stroke: 20mm, Action: D (Double Acting), Rod End Thread: Rod End Female Thread (w/o Thread for ø4), Auto Switch: F8B--Solid State, Gen Purpose, 2 Wire, Vertical
Magnet: D (Built-in Magnet), Mounting Direction: B (Lateral Mounting), Bore Size: 8, Stroke: 20mm, Action: D (Double Acting), Rod End Thread: Rod End Female Thread (w/o Thread for ø4), Auto Switch: F8N--Solid State, Gen Purpose, 3 Wire NPN, Vertical, Lead Wire or Prewired Connector: L (3m)
Magnet: D (Built-in Magnet), Mounting Direction: B (Lateral Mounting), Bore Size: 8, Stroke: 20mm, Action: D (Double Acting), Rod End Thread: Rod End Female Thread (w/o Thread for ø4), Auto Switch: F8P--Solid State, Gen Purpose, 3 Wire PNP, Vertical, Lead Wire or Prewired Connector: L (3m)
Magnet: D (Built-in Magnet), Mounting Direction: B (Lateral Mounting), Bore Size: 8, Stroke: 20mm, Action: D (Double Acting), Rod End Thread: Rod End Female Thread (w/o Thread for ø4), Auto Switch: F8N--Solid State, Gen Purpose, 3 Wire NPN, Vertical, Lead Wire or Prewired Connector: MAPC (1.0m Cord Length, M8-3 Pin Connector), Number: S (1 pc.)
Magnet: D (Built-in Magnet), Mounting Direction: B (Lateral Mounting), Bore Size: 8, Stroke: 20mm, Action: D (Double Acting), Rod End Thread: Rod End Female Thread (w/o Thread for ø4), Auto Switch: F8B--Solid State, Gen Purpose, 2 Wire, Vertical, Lead Wire or Prewired Connector: L (3m)
Magnet: D (Built-in Magnet), Mounting Direction: B (Lateral Mounting), Bore Size: 8, Stroke: 20mm, Action: D (Double Acting), Rod End Thread: Rod End Female Thread (w/o Thread for ø4), Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: Z (5m), Number: S (1 pc.)