L (Example) F8NL 5 m . Z (Example) F8NZ Auto switches marked with are produced upon receipt of order. When using non-applicable auto switches, please consult with SMC.
L (Example) F8NL 5 m . Z (Example) F8NZ Auto switches marked with u are produced upon receipt of order.
Lead wire length symbols: 0.5m Nil (Example) F8N 3 m L (Example) F8NL Auto switch Proper auto switch mounting position (Detection at stroke end) (6, 8, 10 common) Refer to page 182 for a list of applicable auto switches.
Clean Room: 11 (Vacuum Suction Type), Magnet: D (Built-in), Mounting Direction: B (Lateral Mounting), Bore: 6mm, Stroke: 6mm, Rod End Thread: M (Rod End Male Thread), Auto Switch: F8B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: L (3m), Number: S (1 pc.)
Clean Room: 11 (Vacuum Suction Type), Magnet: D (Built-in), Mounting Direction: B (Lateral Mounting), Bore: 6mm, Stroke: 6mm, Rod End Thread: M (Rod End Male Thread), Auto Switch: F8B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: L (3m)
Clean Room: 11 (Vacuum Suction Type), Magnet: D (Built-in), Mounting Direction: B (Lateral Mounting), Bore: 6mm, Stroke: 6mm, Rod End Thread: M (Rod End Male Thread), Auto Switch: M9NW--Solid State, 2-color Indication, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: L (3m), Number: S (1 pc.)
Clean Room: Vacuum Suction Type, Magnet: Built-in, Mounting Direction: Lateral Mounting, Bore: 6mm, Stroke: 6mm, Rod End Thread: Rod End Male Thread, Auto Switch: F8B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: 1 pc.
Clean Room: Vacuum Suction Type, Magnet: Built-in, Mounting Direction: Lateral Mounting, Bore: 6mm, Stroke: 6mm, Rod End Thread: Rod End Male Thread, Auto Switch: F8B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -
Cylinder (Tube) Inner Diameter(φ): 6, Stroke(mm): 6, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Plate Cylinder, Additional Function: Standard, Environment, Applications: Clean Room, Operating Temperature(°C): -, End Locking: No, Valves: No, Operating Pressure(MPa): 0.15 to 0.7, Specification: Built-in magnet,
Cylinder (Tube) Inner Diameter(φ): 6, Stroke(mm): 6, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Plate Cylinder, Additional Function: Standard, Environment, Applications: Clean Room, Operating Temperature(°C): -, End Locking: No, Valves: No, Operating Pressure(MPa): 0.15 to 0.7, Specification: Built-in magnet,
Clean Room: 11 (Vacuum Suction Type), Magnet: D (Built-in), Mounting Direction: B (Lateral Mounting), Bore: 6mm, Stroke: 10mm, Rod End Thread: Rod End Female Thread, Auto Switch: F8N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: L (3m)
Clean Room: 11 (Vacuum Suction Type), Magnet: D (Built-in), Mounting Direction: B (Lateral Mounting), Bore: 6mm, Stroke: 10mm, Rod End Thread: M (Rod End Male Thread), Auto Switch: F8N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: L (3m)
Clean Room: 11 (Vacuum Suction Type), Magnet: D (Built-in), Mounting Direction: B (Lateral Mounting), Bore: 6mm, Stroke: 15mm, Rod End Thread: Rod End Female Thread, Auto Switch: F8N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: L (3m)
Clean Room: 10 (Relief Type), Magnet: D (Built-in), Mounting Direction: B (Lateral Mounting), Bore: 6mm, Stroke: 15mm, Rod End Thread: Rod End Female Thread, Auto Switch: F8N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: L (3m)
Clean Room: 11 (Vacuum Suction Type), Magnet: D (Built-in), Mounting Direction: B (Lateral Mounting), Bore: 6mm, Stroke: 4mm, Rod End Thread: Rod End Female Thread, Auto Switch: F8N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: L (3m)
Clean Room: 10 (Relief Type), Magnet: D (Built-in), Mounting Direction: B (Lateral Mounting), Bore: 6mm, Stroke: 10mm, Rod End Thread: M (Rod End Male Thread), Auto Switch: F8N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: L (3m)
Clean Room: Vacuum Suction Type, Magnet: Built-in, Mounting Direction: Lateral Mounting, Bore: 6mm, Stroke: 10mm, Rod End Thread: Rod End Male Thread, Auto Switch: F8N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -
Clean Room: Vacuum Suction Type, Magnet: Built-in, Mounting Direction: Lateral Mounting, Bore: 6mm, Stroke: 15mm, Rod End Thread: Rod End Female Thread, Auto Switch: F8N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -
Clean Room: Relief Type, Magnet: Built-in, Mounting Direction: Lateral Mounting, Bore: 6mm, Stroke: 15mm, Rod End Thread: Rod End Female Thread, Auto Switch: F8N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -