SMC Corporation of America
Elite Part Number Search
Search Results "CDS1DQ160-600"

H 8 W(kg) 15 30 6 10 20 4 5 2 10 0 0 0 0 200 400 600 800 1000 1200 0 100 200 300 400 500 600 0 200 400 600 800 1000 1200 V (mm/s) V (mm/s) V(mm/s) LEFS16 LEFS25 LEFS32 LECPA Horizontal Transfer 50 12 B B 20 B 10 A A 40 W(kg) A W(kg) H H W(kg) 15 8 30 6 10 20 4 10 5 2 0 0 0 0 100 200 300 400 500 600 0 100 200 300 400 500 600 0 100 200 300 400 500 600 V(mm/s) V (mm/s)

, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 100 1500 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 Note) Intermediate strokes are also available.

(with connector and 2 of sockets only) Rated voltage Lead wire length 5 24 VDC Nil 300 mm 6 12 VDC 6 600 mm Electrical entry V 6 VDC 10 1000 mm Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Grommet, 300 mm lead wire G S 5 VDC 15 1500 mm Grommet, 600 mm lead wire

P When mounted on the manifold, the common exhaust discharges the pilot and main valve exhaust through a common exhaust port to enable simple exhausting. 700 B 600 Max.operating speed (mm/s) Piping length1m JIS Symbol B A 500 Piping length5m A D SY (Single) 400 R P SYJ C 300 SX How to order valve with built-in speed controller SYJ5l 5l--lll l--l 200 VK Port size VZ 100 Config.

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, AIR, LOW FRICTION, ACTUATOR, CS1/CS2 TIE ROD CYLINDER, TE, 125MM CS1/CS2 DBL-ACT AUTO-SW, .00000 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, AIR, LOW FRICTION, ACTUATOR, CS1/CS2 TIE ROD CYLINDER, TE, 125MM CS1/CS2 DBL-ACT AUTO-SW, 51.53305 lb

C85 -XC3 Special port location 63 1200 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 -XC4 With heavy duty scraper C95 80 1400 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 Heat resistant cylinder (110 C) -XC5 100 1500 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 -XC6 Piston rod and rod end nut

C85 -XC3 Special port location 63 1200 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 -XC4 With heavy duty scraper C95 80 1400 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 Heat resistant cylinder (110 C) -XC5 100 1500 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 -XC6 Piston rod and rod end nut

Exhaust center VZS 20 or less 0.43 VFS2400 VFS2410 600 Pressure center VFS 0.43 20 or less VFS2500 VFS2510 600 Double check 25 or less 0.6 VFS2600 VFS2610 600 VS4 Note 1) Based on JIS B 8375 (Once per 30 days) for the minimum operating frequency.

Exhaust center VFS2400 VFS2410 20 or less 0.43 600 Pressure center VFS2510 VFS2500 20 or less 0.43 600 Double check VFS2600 VFS2610 25 or less 0.6 600 Note 1) Based on JIS B 8375 (Once per 30 days) for the minimum operating frequency.

, 600 1000 80 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 1000 100 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 Intermediate strokes are available, too.

Up to 600 Up to 750 Up to 750 Up to 1000 Up to 1000 Up to 1200 With rod boot 20 to 500 20 to 600 20 to 600 20 to 750 20 to 750 30 to 1000 30 to 1000 30 to 1200 1/4 1/4 1/4 1/4 1/4 1/2 1/2 3/4 40 50 63 80 100 125 140 160 30 35 35 40 40 50 50 56 59 67 73 77 85 112.5 121 133 44 52 64 78 92 115 128 144 40 50 55 65 80 90 90 90 27 32 32 37 37 47 47 53 69 78 84 92 100 141.5 150 167 16 20 20 25

, 600 1000 80 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 1000 100 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 Intermediate strokes are available, too.

Without lead wire Nil 6 10 15 20 25 30 300 600 1000 1500 2000 2500 3000 Nil Blue (2) Red (2) Gray (2) Red: +, Black: For 100 VAC For 200 VAC Another VAC For DC 1 2 3 4 Connector Lead wire How to Order Include the connector assembly part number together with the part number for the plug connectors solenoid valve without connector. (Example) 2000 mm lead wire length.

Horizontal Operation (Wall mounting) CY1L40 Model 10 (2.48 1.3 x 103 x ST) = CY3B CY3R 50 Note) Calculate with = 1 for all applications up to 10 300 mmST, 15 500 mmST, 20 500 mmST, 25 500 mmST, 32 600 mmST and 40 600 mmST.

How to Order SY100 68 A Lead wire length Nil 300 mm 6 600 mm 10 15 20 25 30 50 1000 mm Caution 1500 mm 2000 mm 2500 mm 3000 mm 5000 mm Failure to meet IP65 performance may result if using alternative connectors than those shown above, or when insufficiently tightened.

G: 300 H: 600 P=17 L2 4.5 L1 VK Manual override 12.5 (Pitch) Depress and turn to operate and lock override.

VZ Without lead wire: (with connector and 2 of sockets only) SY100-30-A Rated voltage VS 5 6 V S R 1 2 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz [115 VAC 50/60 Hz] Lead wire length Electrical entry VFN Nil 6 10 15 20 25 30 50 300 mm 600 mm 1000 mm 1500 mm 2000 mm 2500 mm 3000 mm 5000 mm G H L LN LO M MN MO WO Grommet, 300 mm lead wire Grommet, 600

Max. suction flow rate 3 types available: 100, 300 *1 , and 600 *1 L/min (ANR) *1 Branch + Port exhaust Silencer Air consumption Max. suction flow rate: 600 L/min (ANR) 91% reduction (Under SMCs measurement conditions) ZL6 Series Suction: 300 L ZL3 Suction: 600 L Reduced by the pressure switch for vacuum with energy saving function and efficient ejectors ZL6 10% reduction Suction: 100 L ZL1