This is a legacy product, and replaced byVK334-5D-Q, VALVE, SOL, BASE MOUNTED, VALVE, VK300 SOL VALVE 3-PORT, 2A, VK300 NO SIZE RATING, .24398 lb
This is a legacy product, and replaced byVFS6110-5D, VALVE SGL NON-PLUG-IN BAS *LQA, VALVE, VFS6000 SOL VALVE 4/5 PORT, 2D, VFS6000, 0.61688 lb
Solenoid: No.3 Solenoid, Body Size: 9 (50A), Style: 0 (Energized Open/N.C.), Option: BC6, Copper Body & Shading Coil, NBR Seal, Class B Coil, Port Size: 20 [2 (50A)], Thread: Rc, Voltage: 5 (24VDC), Lead Wire: D (DIN Connector)
Solenoid: No.3 Solenoid, Body Option: 9 (50A), Style: 0 (Energized Open/N.C.), Option: Brass, Copper or BC6 Body & Shading Coil, NBR Seal, Class B Coil, Port Size: 20 [2 (50A)], Thread: Rc, Voltage: 5 (24VDC), Lead Wire: D (DIN Connector)
Solenoid: No.3 Solenoid, Body Option: 9 (50A), Style: 0 (Energized Open/N.C.), Option: A (Brass, Copper or BC6 Body & Shading Coil, FPM Seal, Class B Coil), Port Size: 20 [2 (50A)], Thread: Rc, Voltage: 5 (24VDC), Lead Wire: D (DIN Connector)
Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 5, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard / Non-use of Copper and fluoropolymer-based Material (Partially Plating), Operating Temperature(°C): -10~60, Cushion: Rubber cushion, Operating Pressure(
Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 5, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Plate Cylinder, Additional Function: Standard, Environment, Applications: Non-use of Copper and fluoropolymer-based Material (Partially Plating), Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating
Cylinder (Tube) Inner Diameter(φ): 6, Stroke(mm): 5, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Plate Cylinder, Additional Function: Standard, Environment, Applications: Non-use of Copper and fluoropolymer-based Material (Partially Plating), Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating
Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 5, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Plate Cylinder, Additional Function: Standard, Environment, Applications: Non-use of Copper and fluoropolymer-based Material (Partially Plating), Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating
Solenoid: No.3 Solenoid, Body Option: 50A, Style: Energized Open/N.C., Option: Brass, Copper or BC6 Body & Shading Coil, NBR Seal, Class B Coil, Port Size: 20 [2 (50A)], Thread: Rc, Voltage: 24VDC, Lead Wire: DIN Connector, Surge Suppressor: -, Bracket: -
Solenoid: No.3 Solenoid, Body Option: 50A, Style: Energized Open/N.C., Option: Brass, Copper or BC6 Body & Shading Coil, FPM Seal, Class B Coil, Port Size: 20 [2 (50A)], Thread: Rc, Voltage: 24VDC, Lead Wire: DIN Connector, Surge Suppressor: -, Bracket: -
Solenoid: No.3 Solenoid, Body Size: 50A, Style: Energized Open/N.C., Option: BC6, Copper Body & Shading Coil, NBR Seal, Class B Coil, Port Size: 20 [2 (50A)], Thread: Rc, Voltage: 24VDC, Lead Wire: DIN Connector, Surge Suppressor: -
Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 5, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Plate Cylinder, Additional Function: Standard, Environment, Applications: Non-use of Copper and fluoropolymer-based Material (Partially Plating), Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating
Cylinder (Tube) Inner Diameter(φ): 6, Stroke(mm): 5, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Plate Cylinder, Additional Function: Standard, Environment, Applications: Non-use of Copper and fluoropolymer-based Material (Partially Plating), Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating
Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 5, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Plate Cylinder, Additional Function: Standard, Environment, Applications: Non-use of Copper and fluoropolymer-based Material (Partially Plating), Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating
Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 5, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard / Non-use of Copper and fluoropolymer-based Material (Partially Plating), Operating Temperature(°C): -10~60, Cushion: Rubber cushion, Operating Pressure(
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product, and replaced byVK332-5D-01T, VALVE, SOL, BODY PORTED, VALVE, VK300 SOL VALVE 3-PORT, CA, VK300 BODY PORT 1/8NPT, 1.58732 lb
This is a legacy product, and replaced byVK332V-5D-01T, VALVE, SOL, BODY PORTED, VALVE, VK300 SOL VALVE 3-PORT, CA, VK300 BODY PORT 1/8NPT, .22000 lb