SMC Corporation of America
Elite Part Number Search
Search Results "CDQ2B100-20DCZ-E-M9NW"

Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 20, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket

Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 20, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket

Magnet: D (Built-in), Mounting: B [Through Hole (Standard)], Type: Standard, Bore Size: 100mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 20mm, Body Option: C (Rubber Bumper), Auto Switch Groove: Z (Auto Switch Mounting Grooves)

BJ6-016S (A set of a, b, d, e) D-H7C 8 9 D-M9m/M9mV D-M9mW/M9mWV D-M9mA/M9mAV 3 3.5 Switch bracket (Resin) Transparent (Nylon) Note 1) Band mounting c e Smooth Cylinders Low Speed Cylinders White (PBT) D-A9m/A9mV 6 6.5 Rail mounting D-A7m/A80/A7H/A80H D-A73C/A80C 8 9 d Switch holder (Zinc die-casted) b D-A79W 11 13 Auto switch mounting screw D-F7m/J79/F7mW/J79W D-F7mV/F7mWV/F79F D-J79C/F7BA

R R: Gripping point distance [mm] 6 MHL2 Series Construction 10 16 to 25 e r t u w y @4 @0 @1 @2 !7 !5 !8 @3 !3 e o i q @6 @7 @3 @5 !9 !0 !2 !1 !6 !4 Component Parts No. Description Material Note 1 Body Aluminum alloy Hard anodized No.

Head Flange: CG3GN Bore size Stroke With rubber bumper Width across flats KA GA GB 4 x FD 8 x J 2 x P F R0.5 H1 0 E 0.05 MM D FX 0.15 0 E 0.05 I B C Corner of the cover (20 to 63) H A AL Width across flats B1 Width across flats NA F FT C FX 0.15 S + Stroke ZZ + Stroke B End boss is machined on the flange for E.

Note 3) Bore size determination E Es NG Determination of allowable stroke (W + WB) V 2 E = x ( ) 2 1000 E Es Note 2) OK Determination of pressure (P) when making intermediate stop Review of order made products based on operating conditions P Ps DNote 1) This cylinder cannot perform an intermediate stop using an air pressure circuit in vertical operation.

(Fig. 1-2) w Bend the reinforcing plate on the nut (M3) side, as shown in Fig. 1-3. e Pass the clip of the switch holder (a) through the square hole in the side of the reinforcing plate that was not bent in step w. (Fig. 1-4 and Fig. 1-5) r Place the switch holder on the cylinder tube in the state of step e. t Wrap the band around the cylinder tube.

C D A B Side support B MY-SB 2 x J MY1B MY1B MY1H E A B MY1B C D MY1M (mm) MY1C A 61 70 87 B C D E F G H J Part no.

Z A + Stroke B + Stroke L W E M K J 2 x P (Rc, NPT, G) (Port size) 100 Auto switch Minimum lead wire bending radius 10 H thread effective depth C 4 x N through F Q I E M Z A + Stroke B + Stroke L W G M K J Standard [mm] Bore size Stroke range Without magnet for auto switch With magnet for auto switch C D E F G H I J K L M N P Q W Z A B A B 50 10 to 50 37 29 42.5 34.5 15 18 57 9 M10 x 1.5

, depth OL WA Z XAH9 XB Section XX Section XX XA XL XC HA: T-slot for hexagon bolt Section XX details X 0.02 R T X 0.02 DB DA H VA VB U X PW b a e d c T-slot dimensions 2 x P XAH9 depth XL 2 x P (Plug) XAH9 depth XL S Q G J K PB GB GA [mm] FA PA + Stroke Bore size [mm] a b c d e FB A + Stroke B + Stroke C + Stroke 32 6.5 10.2 5.5 3.5 9.5 40 6.5 10.5 5.5 4 10 50 8.5 12.5 7.5 4 12.5 E The

1 u t q w e y !2 i r #3 !4 !0 !9 !8 !5 !

Determination of load's kinetic energy (E) E > Es E Es Determination of bore size Review of larger bore size E = m E 2 a ( ) 2 = (Refer to page 1548.) 1000 P Ps P > Ps Determination of pressure for intermediate stop (p) (Refer to page 1548.)

Wn Mass mn X-axis xn xa xb xc xd Y-axis yn ya yb yc yd Z-axis zn za zb zc zd X 1 mt = x (mn x xn)w Wa Wb Wc Wd ma mb mc md Y 1 mt = x (mn x yn)e D1 mt = x {mn x (A + zn)} r Z -X (n = a,b,c,d) Refer to the following sections 1 to 4 to calculate the center of gravity and the total load.

9 e r t q !3 w !0 @3 @2 !1 !2 !5 !4 y u i o @1 @0 !8 !6 Component Parts Component Parts Qty. No. Description Material Note No.

9 e r t q !3 w !0 @3 @2 !1 !2 !5 !4 y u i o @1 @0 !8 !6 Component Parts Component Parts Qty. No. Description Material Note No.

Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ Solid state auto switches marked with are produced upon receipt of order. For D-P3DWA, 32 to 63 are available. DSince there are other applicable auto switches than listed, refer to page 400 for details.

Dimensions (mm) MGPWL, MGPWA 32 to 63/A, E Dimensions (mm) Bore size (mm) A E Bore size (mm) A E 25 st or less Over 25 st 100 st or less Over 100 st 25 st or less 50 st or less Over 25 st 100 st or less Over 50 st 100 st or less Over 100 st Over 100 st 50 st or less Over 50 st 100 st or less Over 100 st D20 25 32 40 50 63 57.5 53.5 62.5 55.5 37.5 33.5 42.5 35.5 20.5 16.5 21.5 14.5 109.5 109.5