Magnet: Built-in Magnet, Mounting: Both Ends Tapped, Bore Size: 63mm, Port Thread: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 25mm, Body Option: Rod End Male Thread, Auto Switch Groove: None (for 12-25 Bore w/o Magnet; 32-100 Bore w/o Magnet Z must be selected), Auto Switch: A93V--Reed, DC Volt, AC Volt, LED, Vertical, Lead Wire or Prewired Connector: 3m, Number: 2 pcs. (Or None in
Magnet: Built-in Magnet, Mounting: Both Ends Tapped, Bore Size: 63mm, Port Thread: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 50mm, Body Option: Rod End Male Thread, Auto Switch Groove: None (for 12-25 Bore w/o Magnet; 32-100 Bore w/o Magnet Z must be selected), Auto Switch: A93V--Reed, DC Volt, AC Volt, LED, Vertical, Lead Wire or Prewired Connector: 3m, Number: 2 pcs. (Or None in
Magnet: Built-in Magnet, Mounting: Both Ends Tapped, Bore Size: 63mm, Port Thread: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 100mm, Body Option: Rod End Male Thread, Auto Switch Groove: ø12 to ø25, 2 Surfaces; ø32 to ø100, 4 Surfaces, Auto Switch: A93V--Reed, DC Volt, AC Volt, LED, Vertical, Lead Wire or Prewired Connector: 3m, Number: 2 pcs. (Or None in the Case of No Switch), Environmental
Magnet: Built-in Magnet, Mounting: Both Ends Tapped, Bore Size: 63mm, Port Thread: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 100mm, Body Option: Standard, Rod End Female Thread, Auto Switch Groove: ø12 to ø25, 2 Surfaces; ø32 to ø100, 4 Surfaces, Auto Switch: A93V--Reed, DC Volt, AC Volt, LED, Vertical, Lead Wire or Prewired Connector: 3m, Number: 2 pcs. (Or None in the Case of No
Magnet: Built-in Magnet, Mounting: Both Ends Tapped, Bore Size: 63mm, Port Thread: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 25mm, Body Option: Rod End Male Thread, Auto Switch Groove: ø12 to ø25, 2 Surfaces; ø32 to ø100, 4 Surfaces, Auto Switch: A93V--Reed, DC Volt, AC Volt, LED, Vertical, Lead Wire or Prewired Connector: 3m, Number: 2 pcs. (Or None in the Case of No Switch), Environmental
Magnet: Built-in Magnet, Mounting: Both Ends Tapped, Bore Size: 63mm, Port Thread: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 15mm, Body Option: Rod End Male Thread, Auto Switch Groove: ø12 to ø25, 2 Surfaces; ø32 to ø100, 4 Surfaces, Auto Switch: A93V--Reed, DC Volt, AC Volt, LED, Vertical, Lead Wire or Prewired Connector: 3m, Number: 2 pcs. (Or None in the Case of No Switch), Environmental
Error Control Services are not set on shipment. (100C, 100D, 1016, 1017h = 0) Node Guarding Protocol and Heartbeat Protocol are not able to be used at the same time. If both Node Guarding Protocol and Heartbeat Protocol are set at the same time, the Heartbeat Protocol is used.
CHQWB40 5D (M) 15D (M) 10D (M) 20D (M) 15D (M) 25D (M) 20D (M) 30D (M) 25D (M) 35D (M) 30D (M) 13.5 10 40D (M) 35D (M) 45D (M) 40D (M) 50D (M) 45D (M) 75D (M) 50D (M) 100D (M) 75D (M) 100D (M) CH QWB50 10D (M) 15D (M) 20D (M) 25D (M) 30D (M) 35D (M) 12 40D (M) 45D (M) 50D (M) 75D (M) 100D (M) 38 Series CHQWB Construction CHQWB20 Rod end male thread CHQWB32 to CHQWB100 Rod end male thread
(M) M10 x 100l x 105l x 110l x 115l x 120l x 125l x 130l x 135l x 140l x 165l x 190l CHQB80 10D (M) 10D (M) 15D (M) 15D (M) 20D (M) 20D (M) 25D (M) 25D (M) 30D (M) 30D (M) 7 35D (M) 35D (M) 14.5 40D (M) 40D (M) 45D (M) 45D (M) 50D (M) 50D (M) 75D (M) 75D (M) x 165l 100D (M) 100D (M) M5 x 75l x 80l x 85l CHQB100 10D (M) M10 x 105l x 110l x 115l x 120l x 125l x 130l x 135l x 140l x 145l x
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
MHSH(J)3-32DA,B M30.5 0.6 6 40DA,B M50.8 2.8 10 50DA,B M61 4.8 12 63DA,B M81.25 12 16 80DA,B M101.5 24 20 A J/ / 8 MHS2 Nm mm MHS2-16D M40.7 2.1 8 20D M40.7 2.1 8 25D M40.7 2.1 8 32D M50.8 4.3 10 40D M61 7.3 12 50D M61 7.3 12 63D M61 7.3 12 MHS3 Nm mm MHS3-16D M30.5 0.66 4.5 20D M30.5 0.88 6 25D M40.7 1.6 6 32D M40.7 1.6 6 40D M50.8 3.2 7.5 50D M50.8 4.3 10 63D M61 5.4 9 80D M61 7.3 12 100D
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
Example) 40D-A3C-4, 50D-A3C-5, 63D-A3C-6, 80D-A3C-8, 100D-A3C-10 To order the mounting brackets separately, use the part number shown above.
Example) 40D-A3C-4, 50D-A3C-5, 63D-A3C-6, 80D-A3C-8, 100D-A3C-10 To order the mounting brackets separately, use the part number shown above.
Single vane Double vane 90, 100D 270S 180S 90S 1) e ot e g 1 n N 8 a 0 4 e g r + 2 n 7 a 4 n + 0 r + o n 0 5 0 4 N 0 ti o 0 9 ot a N ti 0 e t a e ot 0 1) o g t 1 e n e o R ) a 1 0 ot R r ) N 1 n o e 4 ti 0 + a g 0 t o n 9 R ra e n g n io ra (90) (90) at n io Chamfer ot Plate Plate Plate at R ot R Plate (45) Chamfer Chamfer Note 2) Chamfer (45) B port A port B port A port B port A port
Magnet: D (Built-in), Mounting: A (Both Ends Tapped), Type: Standard, Bore Size: 63mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 100mm