Bore size (mm) c e b a d 40 50 63 5.5 7.5 10 10.5 13.5 17.8 11 13.5 18.5 4 4.5 7 6.5 8.5 11 b a c d e Common Dimensions: MVGPM/MVGPL Extension locking Retraction locking IC Standard stroke (mm) Bore size (mm) B C DA FA FB G GA GB GC H HA IA ID IE IH J K L IB 52 64 77 40 46 58 M6 27 32 39 34 35 38 11 13 16.5 4 7 6.5 10 14 34.5 40 50 63 100 120 148 162 16 20 20 14 44 12 16 16 44 47 50 54 64
Bore size (mm) c e b d a 40 50 63 5.5 7.5 10 11 13.5 18.5 10.5 13.5 17.8 4 4.5 7 6.5 8.5 11 b a c d e Common Dimensions: MVGPM/MVGPL Extension locking Retraction locking IC Standard stroke (mm) Bore size (mm) B C DA FA FB G GA GB GC H HA IA ID IE IH J K L IB 52 64 77 40 46 58 M6 27 32 39 34 35 38 11 13 16.5 4 7 6.5 10 14 34.5 40 50 63 100 120 148 162 16 20 20 14 44 12 16 16 44 47 50 54 64
Series MGP Series MGPS (d = Thread O.D.) (d = Thread O.D.) 1.5d or more 2d or more D By-pass port dia. D By-pass port dia. C 0.2 C 0.2 B 0.2 B 0.2 Piping Caution A 0.2 A 0.2 Depending on the operating conditions, piping port positions can be changed by using a plug.
(mm) B C D d H Dd9 Tube dia. (mm) L L Dd9 d l l d m t Used snap ring t m Used snap ring Part No.
position 9.5 4 Most sensitive position 6 842 C 2-Color Indicator Solid State Auto Switch Direct Mounting Type D-M9NW(V)/D-M9PW(V)/D-M9BW(V) RoHS Refer to SMC website for the details of the products conforming to the international standards.
D D D B B B C C C Standard part number MB1 XB13 Single clevis type Double clevis type Center trunnion type 1. The port and cushion valve position symbols are determined as viewed from the rod side (in the case of a standard type cylinder, the ports are always located on the top) shown in the above drawings, with "A" at the top and "B", "C" and "D" following clockwise. 2.
Auto switch model Bore size (mm) D-A9 A dimension D-M9 B dimension C dimension D dimension D-A9 D-M9 D-A9 D-M9 D-A9 D-M9 21.5 76.5 72.5 56.5 60.5 17.5 15 Note) Auto switches cannot be installed in Area C in the case of 15. 25, 32 A dimension D-Y5 D-Y6 D-Y7 B dimension C dimension D dimension Auto switch model D-Y5 D-Y6 D-Y7 D-Y5 D-Y6 D-Y7 D-Y5 D-Y6 D-Y7 D-Z7 D-Z8 D-Z7 D-Z8 D-Z7 D-Z8 D-Z7
case of 15. 25, 32 A dimension D-Y5 D-Y6 D-Y7 B dimension C dimension D dimension Auto switch model D-Y5 D-Y6 D-Y7 D-Y5 D-Y6 D-Y7 D-Y5 D-Y6 D-Y7 D-Z7 D-Z8 D-Z7 D-Z8 D-Z7 D-Z8 D-Z7 D-Z8 Bore size (mm) 25 22 103 103 47 47 78 78 22 32 30.5 117.5 117.5 55.5 55.5 92.5 92.5 30.5 Operating Range Bore size (mm) Auto switch model 32 25 15 D-A9 8 D-M9 3 D-Z7/Z8 9 9 D-Y5/Y6/Y7 6 7 Since this
C D Slider Type/Slide Bearing REAS Slider Type/Ball Bushing REAL 15 (mm) Auto switch model A D-F9 B C D D-A9 D-F9 D-A9 D-F9 D-A9 D-F9 Bore size (mm) 17.5 15 D-A9 21.5 76.5 72.5 56.5 60.5 Note) Auto switches cannot be installed in Area C in the case of 15. 25, 32 (mm) A D-Y5 D-Y7 D-Y7W B C D Auto switch model D-Y5 D-Y7 D-Y7W D-Y5 D-Y7 D-Y7W D-Y5 D-Y7 D-Y7W D-Z7 D-Z8 D-Z7 D-Z8 D-Z7 D-Z8 D-Z7
1 LEF LEJ A A LEL B D-D #3 LEM LEM LEY !6 @3 @3 @5 @4 @7 @2 @4 @5 @1 LES #1 #0 u #2 i y LEPY LEPS !3 C-C A-A LER !8 @6 @8 @9 B w !2 C !7 D LEH LEY -X5 D #4 #4 11LEFS C o !0 !5 11LEJS Motor option: With lock 25A!1 LEC !2 LEC S !3 LEC SS-T @0 LEC Y !9 Motorless LAT Component Parts Component Parts LZ No. Description Material Note 1 Body Aluminum alloy Anodized No.
MXW (d= outside dia. of screw) (d= outside dia. of screw) MXP 1.5d or more 2d or more MG MGP MGQ D By-pass port dia. D By-pass port dia. MGG C 0.2 C 0.2 Unless the cylinder operates to its stroke end, the air cushion's capability cannot be brought into full play.
B A C D A B C D Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 6 46 26 46 26 30 42 42 30 10 48 28 48 28 32 44 44 32 Electrical entry (Fetching direction) Type Model Features D-A90 D-Z80 D-Y69A D-Y69B D-Y7PV D-Y7NWV D-Y7PWV D-Y7BWV 50, 63 Grommet (In-line) Without
U side D side D D D D D D 3 2 1 Stations How to Order Solenoid Valve 10 SV 1 1 0 0 F 5 Note) Clean series Note) Available with manifold block for station additions. Refer to the WEB catalog.
Mounting bolt C D Mounting Bolt Size for NCQ8B056 to 250(Without Auto Switch) (Inch) Model C D Bolt size Model C D Bolt size NCQ8B056-012 025 037 050 062 075 087 100 125 150 175 200 250 300 350 400 NCQ8B075-012 025 037 050 062 075 087 100 125 150 175 200 250 300 350 400 NCQ8B106-012 025 037 050 062 075 087 100 125 150 175 200 250 300 350 400 NCQ8B150-012 025 037 050 062 075 087 100 125 150
side traveling parallelism to A side w D side traveling parallelism to B side q w LEJl40 0.05 0.03 C side D side LEJl63 0.05 0.03 Note) Traveling parallelism does not include the mounting surface accuracy.
model D-A9 D-M9 D-M9W D-A9 D-M9 D-M9W D-A9 D-M9 D-M9W D-A9 D-M9 D-M9W Bore size 15 25 32 19.5 23.5 78.5 74.5 58.5 62.5 23 27 102 98 46 42 79 83 31.5 35.5 116.5 112.5 54.5 50.5 93.5 87.5 Note 1) Auto switches cannot be installed in Area C in the case of 15.
R C US US C R R R R R R R US C US C US C US C US C US C SERIAL NO.
Lead wire length indication Note 1) Applicable auto switch with 5 m lead wire (Z) Reed switch: D-B53/B54, D C 7 3 ( C ) / C 8 0 C , D A 7 3 ( C ) ( H ) / A80C, D-A53/A54, D-Z73, D-90/97/90A/93A Solid state switch: Manufactured upon receipt of order as standard.
Dd9 2-d CL D C L l m CL1 H B MLGC Bore size (mm) Clevis Knuckle Part no.