Note 5) Dimensions other than those marked (LA) are the same as the basic type (no locking type). 598 RS2H Series Auto Switch Mounting 1 Auto Switch Proper Mounting Position (Detection at Stroke End) D-M9 D-M9W D-M9AV D-M9V D-M9WV D-M9A D-A9 D-A9V A B Auto switch Auto Switch Proper Mounting Position (mm) Auto switch model D-M9 D-M9W D-M9AV D-M9V D-M9WV D-M9A D-A9 D-A9V A 9.0 B 23.5 A 11.0
ISO Standard Hydraulic Cylinder 40, 50, 63, 80, 100 CHSD Series 10 MPa CHQ How to Order CHK 100 M9BW CH D SD B 40 CHN Magnet for auto switch Number of auto switches Series type CHM Nil D Without Nil S n 2 pcs. Built-in Symbol D Nominal pressure CHS CHS 1 pc. 10 MPa "n" pcs.
Magnet: D (Built-in Magnet), Mounting: L (Axial Foot), Tube Material: Aluminum Tube, Bore Size: 63mm, Thread: TN (NPT), Stroke: 800mm, Bellows/Cushion: Cushion Both Sides
Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 800, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No
Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 800, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No
Pivot bracket Auto switch Stopping Accuracy Bore size [mm] 32 40 50 63 80 100 Double knuckle joint Lock type Exhaust locking Stopping accuracy [mm] 1.0 Mounting D: Double clevis Pivot bracket N: Yes Rod end bracket W: Double knuckle joint Auto switch D-M9BW: 2 pcs.
D-J51: 5ms or less Lead Wire Length D-A73 L Lead wire length Nil L Z N 0.5m 3m 5m None Applicable for the connector style (DC) only Applicable auto switch with 5 meter lead wire ("Z") Reed switch: D-B53/B54, D-C73 (C)/C80C, D-A73(C)(H)/A80C, D-A53/A54, D-Z73, D-90/97/90A/93A Solid state switch: Manufactured upon receipt of order as standard (Except D-F9/F9lV) The standard lead wire length
Proper Auto Switch Mounting Position (Detection at stroke end) C D A B D-A9, D-A9V D-M9, D-M9V, D-M9W, D-M9WV B B Series model A Series model A Operating range Operating range MY2C16 MY2C16 44 116 48 112 MY2H16 MY2H16 46 114 50 110 MY2HT16 MY2HT16 11 8.5 70 90 74 86 MY2C/H/HT25 MY2C/H/HT25 54 156 58 152 MY2C/H/HT40 MY2C/H/HT40 85 245 89 241 Series model C Series model C D D Operating range
350, 400, 450, 500, 600, 700, 800, 900, 1000 63 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100 80 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200 100 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1300 Intermediate strokes and short strokes other than the above are produced upon receipt of order.
, M9P, M9B, M9NV, M9PV, M9BV D-M9NW, M9PW, M9BW, M9NWV, M9PWV, M9BWV D-M9NA, M9PA, M9BA, M9NAV, M9PAV, M9BAV Reed D-A90, A93, A96, A90V, A93V, A96V Standard 1.
/C8 D-C73C/C80C D-B5/B6 D-B59W D-A3/A4 D-A3A/A44A D-A3C/A44C D-A7/A8 D-A7H/A80H D-A73C/A80C D-A79W D-A5/A6 D-A59W D-A9 D-A9V D-Z7/Z8 D-H7 D-H7C D-H7BAL D-H7F D-H7W D-G5/K5 D-G5BAL D-G59F D-G5NTL D-G5W/K59W D-G39/K39 D-G39A/K39A D-F7/J7 D-J79C D-F7F D-F7BAL D-F7BAVL D-F7V D-F7NTL D-F7W (V) D-F5/J5 D-F5BAL D-F5W/J59W D-F5F D-F5NTL D-G39C/K39C D-M9 D-M9V D-F9W D-F9WV D-F9BAL D-Y59A/Y7P/Y59B
Technical data 595 Series CQSS Proper Auto Switch Mounting Position (Detection at stroke end) Non-rotating rod a) b) Mounting 16 to 25 12 a) b) Mounting D-A9 D-A9V Hs Hs D-M9 D-M9W D-M9AL D-M9V D-M9WV D-M9AVL Hs Hs Proper Auto Switch Mounting Position Auto switch model Bore size (mm) A B W B W A B A Hs Hs B A D-A9V D-M9V/M9WV/M9AVL D-M9/M9W D-A9 12 16 20 25 5.5 4.5 19.5 5.5 17 5.5 4.5 1.5
Consult with SMC regarding water resistant types with the above model numbers. * Solid state auto switches marked with are produced upon receipt of order. ** Since D-A9and D-A9V cannot be mounted on 50, use of D-Z7 or D-Z80 is recommended. * Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ D* Since there are other applicable
Hydraulic Cylinder 20, 25, 32, 40 CHN Series 7 MPa CHQ How to Order CHK CHN CHN CHN 25 100 M9BW L C CHM Auto switch mounting bracket Note) Note) This symbol is indicated when the D-A9 or M9 type auto switch is specified. This mounting bracket does not apply to other auto switches (D-C7 and H7, etc.) Applicable to 20 only.
D-A9/M9/M9W/M9AL auto switches are shipped together (not assembled).
Consult with SMC regarding water resistant types with the above model numbers. 2 1 m type lead wire is only applicable to D-A93. Solid state auto switches marked "" are produced upon receipt of order. Do not indicate lead wire length symbol N (none) for types D-A3, D-A44, D-G-39 or D-K39.
The D-A9/M9/M9W/M9A auto switches are shipped together, (but not assembled). (However, only the auto switch mounting brackets are assembled before shipment.) Note) D-Y59A, Y69A, Y7P, Y7W, Z7, Z80 type cannot be mounted on the CP96 series.
D-A9, M9, M9W, M9A auto switches are shipped together. (not assembled).
How to Order CP96S B W J 32 100 C CP96SD B W J S 32 100 M9BW C With auto switch With auto switch (Built-in magnet) Number of auto switches Mounting B Basic L Axial foot F Rod ange G Head ange C Single clevis D Double clevis Bore size Nil 2 S 1 3 3 n n 32 32 mm 40 40 mm 50 50 mm 63 63 mm 80 80 mm 100 100 mm * Mounting brackets are shipped together, but not assembled.
Auto Switch Mounting Height (mm) D-F5 D-J5 D-F5W D-J59W D-F5BAL D-F59F D-F5NTL Hs D-Z7/Z80 D-Y5/Y6 D-Y7P D-Y7PV D-Y7W D-Y7WV D-Y7BAL Hs Auto switch model D-A9 D-A9V D-M9 D-M9W D-M9AL D-M9V D-M9WV D-M9AVL D-A3 D-G39 D-K39 D-A5 D-A6 D-A59W D-A44 Hs Hs Ht Hs Hs Hs Ht Ht Ht Ht Bore size 125 140 160 69 69.5 69 71.5 116 126 75.5 74.5 69.5 69.5 69.5 70 76 76 76 77.5 124 134 81 80 76 76 76.5 76.5