Magnet: D (Built-in Magnet), Mounting: F (Rod Flange), Tube Material: Aluminum Tube, Bore Size: 80mm, Thread: Rc, Stroke: 600mm, Bellows/Cushion: Cushion Both Sides, Auto Switch: M9BA--Solid State, Water Resist., 2 Wire, Horizontal

Magnet: D (Built-in Magnet), Mounting: F (Rod Flange), Tube Material: Aluminum Tube, Bore Size: 80mm, Thread: Rc, Stroke: 600mm, Bellows/Cushion: Cushion Both Sides, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Made to Order: XC35 (w/Coil Scrapper)

Output Power Current Load Load Current Applicable voltage consumption voltage current leakage load drop D-M9N D-M9NV D-M9NW D-M9NWV NPN DC28V type or less At 10mA DC512 0.8V or 100A or Relay 10mA 40mA less less at PLC 24V or less or less IC circuit D-M9P D-M9PV D-M9PW D-M9PWV DC24V (4.5 to 28V) At 40mA 2V or less PNP type D-M9B D-M9BV D-M9BW D-M9BWV DC24V DC24V 2.5 to 4V 0.8mA or less (DC10

Series: NCDA1 (Standard w/ Magnet), Mounting: D (MP2, Detachable Rear Clevis), Bore Size: 600 (6" - Large Bore), Stroke: 3600 (36"), Air Cushion / Rod Boot: Both Ends (Air Cushion), Thread: Nil (Small Male, Standard, Threaded), Adjustment Range: Not Applicable, Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Horizontal, Lead Wire or Prewired Connector: SDPC (0.5m Cord Length,

Operating Pressure(MPa): 0.08~1.0, Cushion: With cushions on both sides, Specification: Built-in magnet, Support bracket: Basic type, Port thread type: G, Auto Switches: M9BW, Lead Wire Length(m): 0.5, The number of the switches: 2, Type of Auto Switch Mounting: Standard, Rod Boot: Without rod boot, Tube Material: Aluminum tube, Custom-made Specifications: None

Magnet: Built-in Magnet, Mounting: Front Flange, Bore Size: 80mm, Port Thread: Rc, Stroke: 600mm, Rod Boot: None, Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Horizontal, Lead Wire or Prewired Connector: -, Number: -

Magnet: D (Built-in Magnet), Mounting: B (Basic), Tube Material: Aluminum Tube, Bore Size: 80mm, Thread: TF (G), Stroke: 600mm, Bellows/Cushion: Cushion Both Sides, Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Horizontal

Magnet: D (Built-in Magnet), Mounting: F (Rod Flange), Tube Material: Aluminum Tube, Bore Size: 50mm, Thread: Rc, Stroke: 600mm, Bellows/Cushion: Cushion Both Sides, Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Horizontal

Magnet: Built-in Magnet, Mounting: Rod Flange, Tube Material: Aluminum Tube, Bore Size: 50mm, Thread: Rc, Stroke: 600mm, Bellows/Cushion: Cushion Both Sides, Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Horizontal, Lead Wire or Prewired Connector: -, Number: -

Operating Pressure(MPa): 0.08~1.0, Cushion: With cushions on both sides, Specification: Built-in magnet, Support bracket: Basic type, Port thread type: G, Auto Switches: M9BW, Lead Wire Length(m): 0.5, The number of the switches: 2, Type of Auto Switch Mounting: Standard, Rod Boot: Without rod boot, Tube Material: Aluminum tube, Custom-made Specifications: None

Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,

Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,

Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,

Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 80, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,

Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 1000, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No

Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 1000, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No

Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No

Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 110, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,

Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 1200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No

Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 1220, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No