The CLS series cylinder with lock is ideal for applications requiring intermediate and emergency stop and drop prevention. The compact lock unit is lightweight and saves space. A switch is optional on the brake cylinder so the operating state of the lock unit (brake piston) can be detected using the switch signal. By separating the lock mechanism and the brake cylinder, SMC has minimized
Magnet: D (Built-in), Mounting: D (Double Clevis), Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 140mm, Thread: TN (NPT), Stroke: 100mm, Option: Cushion at Both Ends, Cylinder Switch Type: M9P--Solid State , Gen. Purpose, 3 Wire PNP, Horizontal, 0.5M, Lead Wire or Pre-wired Connector: L (3m Lead Wire), Number: 2 pcs. (Or None
Magnet: D (Built-in), Mounting: D (Double Clevis), Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 140mm, Thread: TN (NPT), Stroke: 100mm, Option: Cushion at Both Ends, Cylinder Switch Type: M9P--Solid State , Gen. Purpose, 3 Wire PNP, Horizontal, 0.5M, Lead Wire or Pre-wired Connector: SAPC (0.5m Cord Length, M8-3 Pin Connector
Magnet: D (Built-in), Mounting: D (Double Clevis), Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 140mm, Thread: TN (NPT), Stroke: 100mm, Option: Cushion at Both Ends, Cylinder Switch Type: M9P--Solid State , Gen. Purpose, 3 Wire PNP, Horizontal, 0.5M, Lead Wire or Pre-wired Connector: L (3m Lead Wire), Number: 2 pcs. (Or None
Magnet: D (Built-in), Mounting: D (Double Clevis), Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 140mm, Thread: TN (NPT), Stroke: 400mm, Option: Cushion at Both Ends, Cylinder Switch Type: M9P--Solid State , Gen. Purpose, 3 Wire PNP, Horizontal, 0.5M, Lead Wire or Pre-wired Connector: L (3m Lead Wire), Number: 2 pcs. (Or None
Magnet: D (Built-in), Mounting: D (Double Clevis), Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 140mm, Thread: TN (NPT), Stroke: 200mm, Option: Cushion at Both Ends, Cylinder Switch Type: A93--Reed, DC Volt, AC Volt, LED, Horizontal, 0.5M, Lead Wire or Pre-wired Connector: 0.5m Lead Wire (Or None in the Case of No Switch)
Magnet: D (Built-in), Mounting: D (Double Clevis), Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 140mm, Thread: TN (NPT), Stroke: 300mm, Option: Cushion at Both Ends, Cylinder Switch Type: A93--Reed, DC Volt, AC Volt, LED, Horizontal, 0.5M, Lead Wire or Pre-wired Connector: L (3m Lead Wire), Number: 2 pcs. (Or None in the
Cylinder (Tube) Inner Diameter(φ): 140, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure
Cylinder (Tube) Inner Diameter(φ): 140, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure
Magnet: Built-in, Mounting: Double Clevis, Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 140mm, Thread: NPT, Stroke: 100mm, Option: Cushion at Both Ends, Cylinder Switch Type: M9P--Solid State , Gen. Purpose, 3 Wire PNP, Horizontal, 0.5M, Lead Wire or Pre-wired Connector: 3m Lead Wire, Number: 2 pcs. (Or None in the Case of
Magnet: Built-in, Mounting: Double Clevis, Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 140mm, Thread: NPT, Stroke: 100mm, Option: Cushion at Both Ends, Cylinder Switch Type: M9P--Solid State , Gen. Purpose, 3 Wire PNP, Horizontal, 0.5M, Lead Wire or Pre-wired Connector: 0.5m Cord Length, M8-3 Pin Connector, Number: 2 pcs
Magnet: Built-in, Mounting: Double Clevis, Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 140mm, Thread: NPT, Stroke: 400mm, Option: Cushion at Both Ends, Cylinder Switch Type: M9P--Solid State , Gen. Purpose, 3 Wire PNP, Horizontal, 0.5M, Lead Wire or Pre-wired Connector: 3m Lead Wire, Number: 2 pcs. (Or None in the Case of
Magnet: Built-in, Mounting: Double Clevis, Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 140mm, Thread: NPT, Stroke: 200mm, Option: Cushion at Both Ends, Cylinder Switch Type: A93--Reed, DC Volt, AC Volt, LED, Horizontal, 0.5M, Lead Wire or Pre-wired Connector: 0.5m Lead Wire (Or None in the Case of No Switch), Number: 2 pcs
Magnet: Built-in, Mounting: Double Clevis, Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 140mm, Thread: NPT, Stroke: 150mm, Option: Cushion at Both Ends, Cylinder Switch Type: A53--Reed, DC Volt >5<24, LED, 0.5M, Lead Wire or Pre-wired Connector: 3m Lead Wire, Number: 1 pc., Lock Unit Built-in Magnet: Built-in, Lock Unit Switch
The CLS series cylinder with lock is ideal for applications requiring intermediate and emergency stop and drop prevention. The compact lock unit is lightweight and saves space. A switch is optional on the brake cylinder so the operating state of the lock unit (brake piston) can be detected using the switch signal. By separating the lock mechanism and the brake cylinder, SMC has minimized
The CLS series cylinder with lock is ideal for applications requiring intermediate and emergency stop and drop prevention. The compact lock unit is lightweight and saves space. A switch is optional on the brake cylinder so the operating state of the lock unit (brake piston) can be detected using the switch signal. By separating the lock mechanism and the brake cylinder, SMC has minimized
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, NCG ROUND BODY CYLINDER, NE, 50MM NCG DBL-ACT AUTO-SW, .00000 lb
Model: MSQ, Precision: B (Basic), Size: 70, Suffix: A (Adjuster Bolt), Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: 0.5m [Or None in the Case of No Switch], Number: S (1 pc)
Size: 10mm, Cushion: A (Cushion Pad), Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: S (1 pc.)
Model: MSQ, Precision: Basic, Size: 30, Suffix: Adjuster Bolt, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 1 pc, Thread Type: -