SMC Corporation of America
Elite Part Number Search
Search Results "CDLA2F80-50-D-A93"

Auto Switch Mounting Heights (mm) D-Y59 D-Y7P D-Y7W D-Y7BA D-Z7 D-Z80 D-M9 D-M9W D-M9A D-A9 D-M9V D-M9WV D-M9AV D-A9V D-Y69 D-Y7PV D-Y7WV Bore size (mm) U 22 24.5 31.5 35.5 40.5 50 60.5 73 U 28 30 34.5 39 45 53.5 64 76.5 U 25.5 27.5 U 31.5 35.5 40.5 50 60.5 73 U 31.5 36 42 50.5 61 73.5 20 25 32 40 50 63 80 100 D-A9/A9V models cannot be mounted on 32 to 100. 287 CHKG Series Auto Switch

Single round shaft: ClRA1BT Double shaft (round shaft, with four chamfers): ClRA1BJ Double round shaft: ClRA1BK D D D H H H H UU UU M N 0 0.2 G D L 0 0.2 [mm] [mm] [mm] Size D (g6) H Size D (g6) G H M N UU L Size D (g6) H UU 30 8 25 50 15 36 63 17 41 80 20 50 100 25 60 30 8 6 25 10 8 75 7.8 50 15 11 36 20 15 118 14 63 17 13 41 22 17 139 16 80 20 15 50 25 20 167 19 100 25 19 60 30 25 202 24

Flange size XMD Symbol Nil D C Type KF (NW) K (DN) CF Applicable flange size 25, 40, 50, 63, 80 63, 80 40 (070), 63 (114) XYD V V V V V XMD V V V V V Size 25 40 50 63 80 XYD Nil D KF (NW) K (DN) 25, 40, 50, 63, 80 63, 80 3.

(M)(L)(Z) M9// D-M9N(M)(L)(Z) D-M9P(M)(L)(Z) D-M9B(M)(L)(Z) D-A90(L) D-A93(M)(L)(Z) Nil XL H0 Solid state auto switch y Number of auto switches/Detecting position XLQ Quantity Without auto switch 2 pcs. 1 pc. 1 pc.

D-A80C D-J79C D-F79F D-F7NTL D-BAL D-J79 D-F7W D-J79W D-A79W D-F7WV D-F7V D-F7BAVL D-A7 D-A80 D-A7H D-A80H D-F7 12 to 25 32 to 50 D-A9V D-M9V D-F9WV D-A9 D-M9 D-F9W D-F9BAL 32 to 50 Proper Auto Switch Mounting Position Auto Switch Mounting Height (mm) D-A7H D-A80H D-A73C D-A80C D-F7 D-F79F D-J79 D-F7V D-J79C D-F7W D-J79W D-F7WV D-F7BAVL D-F7BAL D-A7H D-A80H D-F7 D-J79 D-F7W D-J79W D-F7BAL

n (Same surface) 70 + 50 (n 2) (n = 2, 4, 6, 8) Note 1) 75 + 50 (n 2) (n = 2, 4, 6, 8) Note 1) 80 + 50 (n 2) (n = 2, 4, 6, 8) Note 1) 85 + 50 (n 2) (n = 2, 4, 6, 8) Note 1) 90 + 50 (n 2) (n = 2, 4, 6, 8) Note 1) 1 70 75 80 85 90 D-F5l/J59 D-F5lW D-J59W D-F5BA D-F59F 2 (Different surfaces, same surface) 90 95 110 115 120 130 n (Same surface) 90 + 55 (n 4) 2 (n = 4, 8, 12, 16) Note 2

Proper Auto Switch Mounting Position (Detection at stroke end) C D Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com A B Series MY2C Series MY2H Series MY2HT (mm) D-M9, D-M9V (mm) D-M9, D-M9V (mm) D-M9, D-M9V A A A B B B Bore size 16 25 40 Operating range Bore size

Order Made Auto Switches Lead wire containment groove 81 Series REA/REB Auto Switch Specifications Auto switch application table Auto switch model Cylinder model REBH REAH REAL REAS REBR REAR D-A72, D-A73, D-A80 Reed switches Solid state switches D-A72H, D-A73H, D-A76H, D-A80H D-A73C, D-A80C Note 1) Note 1) D-A90, D-A93, D-A96 Note 2) Note 2) D-Z73, D-Z76, D-Z80 D-F79, D-F7P, D-J79

Applicable models: D-A73, A73H, A73C, C73, C73C, D-97, 93A, A93, A93V, D-A33A, A34A, A44A, D-B53, B54 2) However, in the case of a 2 color indicator type auto switch (D-A79W, B59W), note that the switch will be in a normally ON condition if connections are reversed. Never carry a cylinder by its lead wires.

64.5 74.5 U 28 35 38.5 44.5 51 61 71 U 31 38 41.5 47.5 54 64 74 U 27 34 37.5 43.5 50 60 70 20 32 40 50 63 80 100 257 CHQB/CHQWB Series Minimum Auto Switch Mounting Stroke (mm) D-A9 D-A9V D-A7 D-A80 D-A7H D-A80H D-A73C D-A80C D-M9WV D-M9AV D-F7W D-F7WV D-J79W D-F7BAV D-M9W D-M9A D-F7BAL D-F7NT D-F79F D-M9 D-M9V D-F7V D-J79C Auto switch mounting number D-F7 D-J79 D-A79W 1 pc. 5 5 10(5) 10

/C8 D-C73C/C80C D-B5/B6 D-B59W D-A3/A4 D-A3A/A44A D-A3C/A44C D-A7/A8 D-A7H/A80H D-A73C/A80C D-A79W D-A5/A6 D-A59W D-A9 D-A9V D-Z7/Z8 D-H7 D-H7C D-H7BAL D-H7F D-H7W D-G5/K5 D-G5BAL D-G59F D-G5NTL D-G5W/K59W D-G39/K39 D-G39A/K39A D-F7/J7 D-J79C D-F7F D-F7BAL D-F7BAVL D-F7V D-F7NTL D-F7W (V) D-F5/J5 D-F5BAL D-F5W/J59W D-F5F D-F5NTL D-G39C/K39C D-M9 D-M9V D-F9W D-F9WV D-F9BAL D-Y59A/Y7P/Y59B

For D-A93, only outward electrical entry (D dimension) is available. Dimensions in parentheses apply to 12-CXSJ10.

Auto Switch Proper Mounting Position (Detection at Stroke End) (mm) Auto Switch Mounting Height (mm) D-M9l D-M9lW D-M9lA D-A9l Hs 20 26.5 25 29 32 32.5 40 37 50 42.5 63 49.5 D-M9l D-M9lW D-M9lA D-A9l Auto switch model Auto switch model Bore size A B A B 20 12 24 8 20 25 11.5 24.5 7.5 20.5 32 13 25 9 21 40 18 27 14 23 50 20 32 16 28 63 18.5 33.5 14.5 29.5 Bore size Note) Adjust the auto switch

45 55 65 75 100 125 150 175 Z 90.5 90.5 90.5 100.5 113.5 154.5 195.5 253.5 293.5 MXS25L-10 MXS25L-20 MXS25L-30 MXS25L-40 MXS25L-50 MXS25L-75 MXS25L-100 MXS25L-125 MXS25L-150 162 218 258 72 72 Air Slide Table MXS Series Appropriate mounting position for stroke end detection (mm) Reed switch: D-A90, D-A93, D-A96, D-A90V, D-A93V, D-A96V Stroke B Stroke E Model Operating range A 10 40 10 75

70 75 80 GA 22 22 22 22 55 61 102 154 190 KA M 92 92 92 102 115 156 197 255 295 MXS25L-10 MXS25L-20 MXS25L-30 MXS25L-40 MXS25L-50 MXS25L-75 MXS25L-100 MXS25L-125 MXS25L-150 162 218 258 3.11-34 Air Slide Table Series MXS Auto Switch Mounting Position for Stroke End Detection Reed switch: D-A90, D-A93, D-A96, D-A90V, D-A93V, D-A96V Stroke B Stroke E Model Operating range A 10 20 30 40 75 100

44.5 A 19.5 29.5 35.5 43 44 53 D 7.5 5 2 5 7 7.5 MY 6 10 15 20 25 32 CY MG CX Note 1) 6: D-A90, D-A96, D-A93, D-F9BAL 10: D-A90, D-A96, D-A93 Only outward electrical entry (D dimension) is available.

44.5 A 19.5 29.5 35.5 43 44 53 D 7.5 5 2 5 7 7.5 MY 6 10 15 20 25 32 CY MG Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com CX Note 1) 6: D-A90, D-A96, D-A93, D-F9BAL 10: D-A90, D-A96, D-A93 Only outward electrical entry (D dimension) is available.

Series 10-, 11-CQSX Series 10-, 11-CQ2X How to Order How to Order Clean Series 10 11 Clean Series 10 11 Relief type Vacuum type Relief type Vacuum type C(D)QSX B 20 10 30 F9BW C(D)Q2XB 40 10 30 J79W D D Built-in magnet Built-in magnet Low speed cylinder Mounting style Low speed cylinder Bore size 32 40 50 63 2 pcs. 1 pc. n pcs.

Nil C M 40 50 63 80 100 40 mm 50 mm 63 mm 80 mm 100 mm Standard stroke Refer to Standard Stroke on page 10-3-13. D Double acting Applicable Auto Switch/Refer to page 10-20-1 for further information on auto switches.

+ 30 (n 2) (n = 2, 3, 4) D-G39 D-K39 D-A3m n (Same surface) 100 + 100 (n 2) (n = 2, 3, 4) 1 10 2 (Different surfaces) 35 2 (Same surface) 50 n (Different surfaces) 35 + 30 (n 2) (n = 2, 3, 4) D-A44 n (Same surface) 50 + 50 (n 2) (n = 2, 3, 4) 1 10 D-F5m D-J59 D-F5mW D-J59W D-F5BA D-F59F 2 (Different surfaces, same surface) 1 15 n 15 + 55 (n 2) 2 (n = 2, 4, 6, 8)*1 2 (Different surfaces