Kit components main parts MIS12-10D MI-A1201-10 MI-A1202-10 MI-A1203-10 MIS12-20D MI-A1201-20 MI-A1202-20 MI-A1203-20 MIS12-30D MI-A1201-30 MI-A1202-30 MI-A1203-30 MIS20-10D MI-A2001-10 MI-A2002-10 MI-A2003-10 MIS20-20D MI-A2001-20 MI-A2002-20 MI-A2003-20 MIS20-30D MI-A2001-30 MI-A2002-30 MI-A2003-30 Standard Finger Tapped on upper and lower faces Tapped on all faces 3 12 13 14 20 Seal kit
MHZ2-16D MHZ2-20D MHZ2-25D 1 N1 MHZ2-10D MHZ2-16D MHZ2-20D MHZ2-25D Specifications and dimensions other than the above are the same as the basic type (including narrow type).
MHL2-10D MHL2-16D MHL2-16D MHL2-10D 2 1 2 1 60 60 25 25 0.6MPa 0.6MPa Holding force (N) Holding force (N) Holding force (N) Holding force (N) 50 50 20 20 0.5MPa 0.6MPa 0.5MPa 0.6MPa 40 40 15 15 0.4MPa 0.5MPa 0.4MPa 0.5MPa 0.4MPa 0.4MPa 30 30 10 10 0.3MPa 20 20 0.3MPa 0.3MPa 0.3MPa 0.2MPa 5 5 10 10 0.2MPa 0.2MPa 0.2MPa 10 20 30 40 50 60 70 20 40 60 80 100 120 20 40 60 80 100 120 0 0 0 10 20
Magnet: D (Built-in Magnet), Bore Size: 16, Port Thread: Bore: 6, 10, 16, 20, 25, M5x0.8 ; Bore: ø32, Rc1/8, Stroke: 10mm, Auto Switch: A90--Reed, AC Volt, Horizontal, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: S (1 pc.)
Magnet: D (Built-in Magnet), Bore Size: 6, Port Thread: Bore: 6, 10, 16, 20, 25, M5x0.8 ; Bore: ø32, Rc1/8, Stroke: 10mm, Auto Switch: A90--Reed, AC Volt, Horizontal, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: S (1 pc.)
Magnet: D (Built-in Magnet), Bore Size: 10, Port Thread: Bore: 6, 10, 16, 20, 25, M5x0.8 ; Bore: ø32, Rc1/8, Stroke: 10mm, Auto Switch: A90--Reed, AC Volt, Horizontal, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: S (1 pc.)
Magnet: D (Built-in), Mounting: L (Foot), Bore Size: Ø10 mm, Stroke: 10 mm, Rod End Thread: With Thread, Auto Switch: A90--Reed, DC Volt >5<24, AC Volt <100, LED, 2 Wire, 0.5M, Lead Wire or Prewired Connector: 0.5m [Or None in the Case of No Switch], Number: S (1 pc.)
Magnet: D (Built-in), Mounting: L (Foot), Bore Size: Ø16 mm, Stroke: 10 mm, Rod End Thread: With Thread, Auto Switch: A90--Reed, DC Volt >5<24, AC Volt <100, LED, 2 Wire, 0.5M, Lead Wire or Prewired Connector: 0.5m [Or None in the Case of No Switch], Number: S (1 pc.)
Magnet: D (Built-in), Mounting: B (Basic), Bore Size: Ø10 mm, Stroke: 10 mm, Rod End Thread: With Thread, Auto Switch: A90--Reed, DC Volt >5<24, AC Volt <100, LED, 2 Wire, 0.5M, Lead Wire or Prewired Connector: 0.5m [Or None in the Case of No Switch], Number: S (1 pc.)
Magnet: D (Built-in), Mounting: B (Through Hole, Both Ends Tapped), Bore Size: 12mm, Stroke: 10mm, Option: Standard (Rod End Female Thread), Auto Switch: A90--Reed, AC Volt, Horizontal, 0.5m, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: S (1 pc.)
Magnet: D (Built-in), Mounting: B (Through Hole, Both Ends Tapped), Bore Size: 16mm, Stroke: 10mm, Option: Standard (Rod End Female Thread), Auto Switch: A90--Reed, AC Volt, Horizontal, 0.5m, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: S (1 pc.)
Magnet: D (Built-in), Mounting: B (Through Hole, Both Ends Tapped), Bore Size: 25mm, Stroke: 10mm, Option: Standard (Rod End Female Thread), Auto Switch: A90--Reed, AC Volt, Horizontal, 0.5m, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: S (1 pc.)
Magnet: Built-in Magnet, Bore Size: 16, Port Thread: Bore: 6, 10, 16, 20, 25, M5x0.8 ; Bore: ø32, Rc1/8, Stroke: 10mm, Auto Switch: A90--Reed, AC Volt, Horizontal, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 1 pc.
Magnet: Built-in Magnet, Bore Size: 6, Port Thread: Bore: 6, 10, 16, 20, 25, M5x0.8 ; Bore: ø32, Rc1/8, Stroke: 10mm, Auto Switch: A90--Reed, AC Volt, Horizontal, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 1 pc.
Magnet: Built-in Magnet, Bore Size: 10, Port Thread: Bore: 6, 10, 16, 20, 25, M5x0.8 ; Bore: ø32, Rc1/8, Stroke: 10mm, Auto Switch: A90--Reed, AC Volt, Horizontal, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 1 pc.
Magnet: Built-in, Mounting: Through Hole, Both Ends Tapped, Bore Size: 12mm, Stroke: 10mm, Option: Standard (Rod End Female Thread), Auto Switch: A90--Reed, AC Volt, Horizontal, 0.5m, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 1 pc., Thread: -
Magnet: Built-in, Mounting: Through Hole, Both Ends Tapped, Bore Size: 16mm, Stroke: 10mm, Option: Standard (Rod End Female Thread), Auto Switch: A90--Reed, AC Volt, Horizontal, 0.5m, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 1 pc., Thread: -
Magnet: Built-in, Mounting: Foot, Bore Size: Ø10 mm, Stroke: 10 mm, Rod End Thread: With Thread, Auto Switch: A90--Reed, DC Volt >5<24, AC Volt <100, LED, 2 Wire, 0.5M, Lead Wire or Prewired Connector: 0.5m [Or None in the Case of No Switch], Number: 1 pc., Option: -
Magnet: Built-in, Mounting: Foot, Bore Size: Ø16 mm, Stroke: 10 mm, Rod End Thread: With Thread, Auto Switch: A90--Reed, DC Volt >5<24, AC Volt <100, LED, 2 Wire, 0.5M, Lead Wire or Prewired Connector: 0.5m [Or None in the Case of No Switch], Number: 1 pc., Option: -
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 10, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: High rigidity / high precision high class guide, Environment, Applications: Standard, Cushion: None, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Auto Switches