Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 60, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Rubber cushion, Auto Switches: A93, Lead Wire
Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 60, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Rubber cushion, Auto Switches: M9NW, Lead
Magnet: D (Built-in), Series: J2, Mounting: D (Double Clevis), Bore Size: 10mm, Stroke: 60mm, Cushion: Rubber Bumper, Head Cover Port Location: Perpendicular to Axis, Pivot Bracket: None, Rod End Bracket: W (Double Knuckle Joint), Auto Switch: M9NW--Solid State, 2-color Indication, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: L (3m), Number: S (1 pc.), Auto Switch Mounting Type: B
(Or None in the Case of No Switch), Auto Switch Mounting Type: B (Band Mounting)
(Or None in the Case of No Switch), Auto Switch Mounting Type: B (Band Mounting)
Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 60, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Rubber cushion, Auto Switches: A93, Lead Wire
Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 60, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Rubber cushion, Auto Switches: M9NW, Lead
Type Symbol B Nil Rc F G N NPT *1 Bracket is included, (but not assembled).
L V B 40 20 M9BW 85K Double acting, Single rod Number of auto switches Built-in magnet Auto switch mounting type*1 Nil 2 S 1 n n Nil None D Built-in magnet A Rail mounting B Band mounting *1 The symbol is Nil for no magnet.
Order 100 M9BW CH D SD B 40 Magnet for auto switch Number of auto switches Series type Without Nil D Nil S n 2 pcs.
MB B 32 50 XC89 Z MDB B 32 50 M9BW Z XC89 Built-in auto switch magnet MB B 32 50 XC91 Z MDB B 32 50 M9BW Z XC91 Built-in auto switch magnet Rod material XC91 S45C Accessories 1 Mounting B L F G C D T Nil N No bracket Pivot bracket Bore size 32 40 50 63 80 100 Basic Axial foot Rod flange Head flange Single clevis Double clevis Center trunnion Number of auto switches Auto switch 32 mm 40 mm
CM2 A B Z 40 150 CDM2 With auto switch M9BW 150 A B 40 Z Port thread type Number of auto switches Rod end bracket With auto switch (Built-in magnet) Nil Rc TN NPT TF G Nil None V Single knuckle joint W Double knuckle joint Mounting Nil 2 pcs. S 1 pc. n n pcs.
CM2 R 20 100 A A CDM2 20 100 A A M9BW R With auto switch Number of auto switches Mounting style With auto switch (Built-in magnet) Bottom mounting style A B 2 pcs. Nil S n Front mounting style 1 pc. n pcs.
form 100 0 20 seconds D-X 1167 Smooth Cylinder Series CQSY 12, 16, 20, 25 How to Order B 20 D 30 C CQSY M9BW B D 20 30 C CDQSY With auto switch Number of auto switches Nil S n With auto switch (Built-in magnet) 2 pcs. 1 pc. n pcs.
N Rubber bumper 100 CG1 25 B S Z N CDG1 With auto switch M9BW 100 B 25 N S Z With auto switch (Built-in magnet) Number of auto switches Rod end thread Mounting Nil Male rod end F Female rod end Nil 2 pcs. S 1 pc. n n pcs.
25 Without auto switch 30D CQ2KW B 32 Z 32 to 63 M9BW 30 32 D Z B CDQ2KW With auto switch Number of auto switches With auto switch (Built-in magnet) Nil S n 2 pcs. 1 pc. n pcs.
Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Rubber cushion, Auto Switches: M9BW, Lead
(Or None in the Case of No Switch), Auto Switch Mounting Type: B (Band Mounting)
Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Rubber cushion, Auto Switches: M9BW, Lead
Technical data 347 Series MB1K Standard Type Basic style: (B) G W V Port Cushion valve G 2 x P B MM Ee11 Width across flats C B Rod sectional view H1 MB B' Effective thread 2 x 4 x J 16 N ZZ + Stroke S + Stroke H A F N C B Cylinder tube sectional view B-B Stroke range Bore size (mm) Effective thread length Width across flats A C B E F G H1 MB J MM N P S V W H ZZ 32 40 50 63 80 100 32.5 38