Auto Switch Mounting Position Auto Switch Mounting Height D-A7H/J79W D-A80H/F7BAL D-F7/F7F D-F79/F7NTL D-F7W D-A72/A7H/A80H D-A73C/A80C D-F7/F7V/F7W D-F7WV/F7BAL D-J7 D-A73C D-A80C D-F7WV D-F7V D-J79C D-A7/A8 D-A79W D-A73 D-A80 D-A79W D-F7F D-F7NTL Bore size (mm) Bore size (mm) A B A B A B A B A B Hs Hs Hs Hs Hs Hs 20 25 32 40 50 63 80 100 20 25 32 40 50 63 80 100 40.5 39.5 40 39 37.5 36.5
Auto Switch Mounting Height (mm) D-A7H D-A80H D-F7 D-J79 D-F7W D-J79W D-F7BAL D-F79F D-F7NTL Auto switch model D-F7V D-F7WV D-F7BAVL D-J79C D-A79W D-A7 D-A80 D-A73C D-A80C D-P4DWL Bore size (mm) Hs Hs Hs Hs Hs Hs Hs 20 25 32 40 50 63 80 100 D31.5 32.5 38.5 35 38 34 -X 35 36 42 38.5 41.5 37.5 44 41 42 48 44.5 47.5 43.5 50 Individual -X 47.5 48.5 54.5 51 54 50 56.5 57.5 58.5 64.5 61 64 60
If it is long, this may cause unlocking malfunction and reduce the lock's service life, etc. 50 50 Load weight kg Load weight kg 100 100 80 80 10 10 63 63 5 5 50 50 40 40 32 32 1 1 0.5MPa 0.4MPa 0.5MPa 0.4MPa 25 25 0.5 0.5 20 20 100 500 100 500 Maximum speed mm/s Maximum speed mm/s Extension locking, Rubber bumper Retraction locking, Rubber bumper W 200 200 100 100 B 50 A 50 A 100 100 Load
) With auto switch: 10C to 60C (No freezing) Female thread Ambient and fluid temperature Rod end thread Stroke length tolerance Mounting Piston speed +1.0 0 Through-hole 50 to 500 mm/s Standard Stroke Standard stroke (mm) Bore size (mm) 20, 25 32, 40 50, 63 80, 100 15, 20, 25, 30, 40, 50 20, 25, 30, 40, 50, 75, 100 30, 40, 50, 75, 100 40, 50, 75, 100 Made to Order (For details, refer to pages
Mounting bolt C D Mounting bolt Mounting bolt Model C D 50 55 60 65 75 85 55 60 65 70 80 90 60 65 70 80 90 115 140 Model C D 65 70 75 85 95 120 145 85 95 105 130 155 90 100 110 135 160 105 115 140 165 120 130 155 180 R(D)QB20-15 -20 -25 -30 -40 -50 R(D)QB25-15 -20 -25 -30 -40 -50 R(D)QB32-20 -25 -30 -40 -50 -75 -100 R(D)QB40-20 -25 -30 -40 -50 -75 -100 R(D)QB50-30 -40 -50 -75 -100 R(D)QB63
Bore size (mm) 32, 40 50, 63 B D E F M T1 T2 Part No. YA 03 YA-03 YA-05 18 20 6.8 9 16 20 6 8 42 50 6.5 6.5 10 12 Applicable air cylinder bore Bore size (mm) 32, 40 50, 63 03 05 32, 40 50, 63 U V W Mass (g) Part No.
Q + Stroke (NA) Cylinder form 12 16 (mm) d Bore size (mm) Standard stroke (mm) A B C E G GP H HA HG HN HP HT J JK L LD Slide Ball bushing 12 15, 25 8 4 16 25 7.5 50 34 6 14.5 34 33 18 M5 x 0.8 9.5 68 4.3 8.5 10 16 15, 25 9.5 5 18 29 6.5 65 40 6.5 16 39.5 39 21 M6 x 1 9.5 75 5.2 7.5 12 20 25, 50 11 6.5 25 36 8.5 80 46 9 18 44.1 45 24 M8 x 1.25 10 86 6.9 9.5 16 25 25, 50 11 6.5 25 40 8.5 90
Cylinder 50, 63, 80 RS1H M9W 50 D L Number of auto switches Bore size 50 63 80 50 mm 63 mm 80 mm (auto switch number mounted) Port thread type 2 pcs. 1 pc.
Bore size 6 6 mm 10 10 mm Magnetic holding force 50 50 mm Switch rail Applicable bore size (mm) Holding force type 63 63 mm H 6, 10, 50, 63 Nil With switch rail L 50, 63 N Without switch rail Refer to Magnetic Holding Force on page 8-15-33. Note 1) Symbol N is standard type only. Note 2) With the switch rail, a built-in switch magnet is also included.
-35 -40 -45 -50 CDQMB32-5 -10 -15 -20 -25 -30 -35 -40 -45 -50 -75 -100 30 35 40 45 50 55 30 35 40 45 50 55 35 40 45 50 55 60 65 70 75 80 40 45 50 55 60 65 70 75 80 85 40 45 50 55 60 65 70 75 80 85 110 135 45 50 55 60 65 70 75 80 85 90 115 140 55 60 65 70 75 80 85 90 95 120 145 M3 x 30 x 35 x 40 x 45 x 50 x 55 M3 x 30 x 35 x 40 x 45 x 50 x 55 M5 x 35 x 40 x 45 x 50 x 55 x 60 x 65 x 70 x 75
75, 100 Rod end nut 52.5 40.5 50 43.5 Front flange type: CLQF50 50 67 A + Stroke 18 9 B + Stroke 35 4-6.6 89 76 Front flange type (mm) Stroke range Without auto switch With auto switch Bore size (mm) A B A B 93.5 30.5 40.5 83.5 93.5 10 to 50 75, 100 Rod end nut 40.5 50 43.5 Rear flange type: CLQG50 50 67 4-6.6 89 76 8 9 A + Stroke B + Stroke 35 Rear flange type (mm) Stroke range Without
25 30 35 40 45 50 75 -100 CQMB6310 15 20 25 30 35 40 45 50 75 -100 CQMB8010 15 20 25 30 35 40 45 50 75 -100 CQMB10010 15 20 25 30 35 40 45 50 75 -100 50 55 60 65 70 75 80 85 90 125 150 55 60 65 70 75 80 85 90 95 130 155 65 70 75 80 85 90 95 100 105 140 165 30 35 40 45 50 55 60 65 70 75 110 135 35 40 45 50 55 60 65 70 75 80 115 140 45 50 55 60 65 70 75 80 85 120 145 M8 x 50L x 55L x 60L x
Hs A B A B 32 to 50 D-A73C D-A80C D-J79C D-A79W D-F7W D-F7V Approx. Hs Approx.
Stroke (mm) Bore size 25 25 mm Port thread type 32 32 mm Bore size 25, 32, 40 50, 63 32, 50, 63 Type Rc NPT G Symbol Nil TN TF 40 40 mm 50 50 mm 63 63 mm Specifications 25 32 40 50 63 Bore size (mm) Fluid Air Proof pressure 1.05 MPa Maximum operating pressure 0.7 MPa Minimum operating pressure 0.18 MPa 10 to 60C (No freezing) Ambient and fluid temperature Piston speed (Max.)
Added weight: 0.16/50 stroke Stroke: 100mm stroke 0.42 + 100 / 50 X 0.16 = 0.74 kg D-A7l D-A80 D-A73C D-A80C CQ2 D-F7lV D-J79C Number of auto switches D-F7lWV MU 2 5 10 15 15 1 5 5 10 15 Construction Component Parts No.
for full strokes 25, 50 and 75.
moment of inertia [kgm2] Allowable moment of inertia [kgm2] 102 102 MK 103 103 50, 63 Standard arm single unit 32, 40 Standard arm single unit 104 50 100 200 104 50 100 200 Maximum piston speed [mm/s] Maximum piston speed [mm/s] 386 Model Selection MK Series Note) Maximum piston speed is equivalent to approximately 1.6x the average piston speed.
50 U 19.5 24.5 31.5 35 41 47.5 12 20 32 40 50 63 Auto switch mounting brackets BQ2-012 are not used for sizes over 32 of D-A9V/M9V/M9WV/M9AVL types.
D-F7, J79 D-F7V D-J79C D-F7W, J79W D-F7WV D-F7BAL D-F79F D-F7NTL Stroke range Only available for full strokes of 5 to 295 mm CEP1 Part no.: RZQA50-135-50 D-A7, A80 Example A 15 mm spacer is installed in a standard cylinder D-A73C, A80C CE1 RZQA50-150-50. The B dimension is 246.5 mm.
D-F7, J79 D-F7V D-J79C D-F7W, J79W D-F7WV D-F7BAL D-F7F D-F7NTL Stroke range Only available for full strokes of 5 to 295 mm Part number: RZQA50-135-50 D-A7, A80 Example A 15 mm spacer is installed in a standard cylinder D-A73C, A80C RZQA50-150-50. The B dimension is 246.5 mm.