Magnet: D (Built-in), Mounting: F (Front Flange), Style: A (Non-lube Air Cushion), Bore Size: 40mm, Stroke: 200mm, Rod Boot: w/o Rod Boot, Lock Position: H (Rear Lock), Release of Manual: L (Locking)
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Non-use of Copper and fluoropolymer-based Material (Partially Plating), End Locking: [Included] Presence, Valves: -, Cushion: Air cushion, Operating Pressure(
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Non-use of Copper and fluoropolymer-based Material (Partially Plating), End Locking: [Included] Presence, Valves: -, Cushion: Air cushion, Operating Pressure(
Magnet: Built-in, Mounting: Front Flange, Style: Non-lube Air Cushion, Bore Size: 40mm, Stroke: 100mm, Rod Boot: w/o Rod Boot, Lock Position: Rear Lock, Release of Manual: Locking, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, Auto Switch Mounting Bracket: -
Magnet: Built-in, Mounting: Front Flange, Style: Non-lube Air Cushion, Bore Size: 40mm, Stroke: 800mm, Rod Boot: w/o Rod Boot, Lock Position: Rear Lock, Release of Manual: Locking, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, Auto Switch Mounting Bracket: -
Magnet: Built-in, Mounting: Front Flange, Style: Non-lube Air Cushion, Bore Size: 40mm, Stroke: 200mm, Rod Boot: w/o Rod Boot, Lock Position: Rear Lock, Release of Manual: Locking, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, Auto Switch Mounting Bracket: -
Impact acceleration [m/s] 5 0 50 100 150 200 250 300 Speed [mm/s] Relationship between speed and impact acceleration Features 1 in vacuum environments (1.3 x 10-Pa) Carefully designed for low particulate generation, low leakage, and low outgassing.
Impact acceleration [m/s] 5 0 50 100 150 200 250 300 Speed [mm/s] Relationship between speed and impact acceleration Features 1 in vacuum environments (1.3 x 10-Pa) Carefully designed for low particulate generation, low leakage, and low outgassing.
Impact acceleration [m/s2] 5 0 50 100 150 200 250 300 Speed [mm/s] Relationship between speed and impact acceleration 8-18-2 in vacuum environments (1.3 x 104 Pa) Carefully designed for low particulate generation, low leakage, and low outgassing.
Note 1) Please consult with SMC if other specifications for surface treatment are required. 0 50 100 150 200 250 300 Speed [mm/s] Relationship between speed and impact acceleration Laser marking Hexagon wrench 8-18-2 8-18-3 3 Series CYV Model Selection 1 Caution on Design (1) The allowable load mass moment differs depending on the workpiece mounting method, cylinder mounting orientation and
Specifications Air Fluid Max. 50C Ambient and fluid temperature (C) Response time (ms) (1) 10ms or less Base mounted 20 Max. operating frequency (Hz) Manual override Non-locking push, Locking slotted, Push-locking slotted, Push-locking lever Not requited Lubrication JIS Symbol Free Mounting position Impact/Vibration resistance (m/s2) (2) 150/30 SY11 (A) 3 4 SY12 (A) 3 4 Dust-proof Enclosure
Standard stroke Bore size (mm) Standard stroke (mm) Piping port position 15, 32 100, 150, 200, 250, 300, 350 400, 450, 500, 600, 700 Operating direction: Right Operating direction: Left Operating direction: Right Operating direction: Left Operating direction: Right Operating direction: Left Operating direction: Right Operating direction: Left a b c d e f g h Nil Note 1) Consult SMC if the
Standard stroke Bore size (mm) Standard stroke (mm) Piping port position 15, 32 100, 150, 200, 250, 300, 350 400, 450, 500, 600, 700 Operating direction: Right Operating direction: Left Operating direction: Right Operating direction: Left Operating direction: Right Operating direction: Left Operating direction: Right Operating direction: Left a b c d e f g h Nil Note 1) Consult SMC if the
Standard stroke Bore size (mm) Standard stroke (mm) Piping port position 15, 32 100, 150, 200, 250, 300, 350 400, 450, 500, 600, 700 Operating direction: Right Operating direction: Left Operating direction: Right Operating direction: Left Operating direction: Right Operating direction: Left Operating direction: Right Operating direction: Left a b c d e f g h Nil Note 1) Consult SMC if the
Standard stroke -X Bore size (mm) Standard stroke (mm) Piping port location 15, 32 100, 150, 200, 250, 300, 350 400, 450, 500, 600, 700 Operating direction: Right Operating direction: Left Operating direction: Right Operating direction: Left Operating direction: Right Operating direction: Left Operating direction: Right Operating direction: Left a b c d e f g h 20Nil Note 1) Please consult
Standard stroke -X Bore size (mm) Standard stroke (mm) Piping port location 15, 32 100, 150, 200, 250, 300, 350 400, 450, 500, 600, 700 Operating direction: Right Operating direction: Left Operating direction: Right Operating direction: Left Operating direction: Right Operating direction: Left Operating direction: Right Operating direction: Left a b c d e f g h 20Nil Note 1) Please consult
Magnet: D (Built-in), Mounting: F (Front Flange), Style: A (Non-lube Air Cushion), Bore Size: 40mm, Stroke: 125mm, Rod Boot: w/o Rod Boot, Lock Position: H (Rear Lock), Release of Manual: N (Non-locking Type), Auto Switch: H7B--Solid State, Gen. Purpose, 2 Wire, Lead Wire, 0.5M, Lead Wire or Prewired Connector: L (3m)
Magnet: D (Built-in), Mounting: F (Front Flange), Style: A (Non-lube Air Cushion), Bore Size: 40mm, Stroke: 300mm, Rod Boot: w/o Rod Boot, Lock Position: H (Rear Lock), Release of Manual: N (Non-locking Type), Auto Switch: H7B--Solid State, Gen. Purpose, 2 Wire, Lead Wire, 0.5M, Lead Wire or Prewired Connector: L (3m)
Magnet: D (Built-in), Mounting: F (Front Flange), Style: A (Non-lube Air Cushion), Bore Size: 40mm, Stroke: 50mm, Rod Boot: w/o Rod Boot, Lock Position: H (Rear Lock), Release of Manual: N (Non-locking Type), Auto Switch: H7B--Solid State, Gen. Purpose, 2 Wire, Lead Wire, 0.5M, Lead Wire or Prewired Connector: L (3m)
Magnet: D (Built-in), Mounting: F (Front Flange), Style: A (Non-lube Air Cushion), Bore Size: 40mm, Stroke: 200mm, Rod Boot: w/o Rod Boot, Lock Position: H (Rear Lock), Release of Manual: N (Non-locking Type), Auto Switch: H7B--Solid State, Gen. Purpose, 2 Wire, Lead Wire, 0.5M, Lead Wire or Prewired Connector: L (3m)