SMC Corporation of America
Elite Part Number Search
Search Results "CDBA2F50-125-HN-J59"

HR MO RF WL WL KA 0.1 C 8-J NA (mm) Stroke range Bore size (mm) A AL B1 C D DL2 E F GA GB H H1 HR HN (max.)

(Band) Cylinder series Applicable bore size (mm) 200 40 180 160 32 140 50 20 25 63 80 100 125 CDV3, CDVS CE2, CNA CDL1 CDS1 BD1 -04M BD1 -05M BD1 -06M BD1 -08M BD1 -10M BS1 -125 BS1 -140 BS1 -160 BS1 -180 BS1 -200 BD1 -01M BD1 -02M BD1 -02 BD1 -04M RHC BMB1 -050 BMB1 -063 BMB1 -080 BMB1 -100 BMB2 -032 BMB2 -040 MDB 7-9-41 42 Technical Data 2: How to Mount and Move the Auto Switch Mounting

125 125 125 125 125 401 to 500 150 150 150 150 501 to 600 175 175 601 to 700 187.5 187.5 701 to 750 73 81 89 89 101 101 1 to 50 86 94 102 102 114 114 51 to 100 98 106 114 114 126 126 101 to 150 111 119 127 127 139 139 201 to 300 161 169 177 177 189 189 301 to 400 186 194 202 202 214 214 401 to 500 227 227 239 239 501 to 600 264 264 601 to 700 276 276 701 to 750 32 40 50 63 80 100 36

1/8 HN-T1 1/8 HNX1 1/8 HN-T2 1/8 HN-T4 Page 10 Distributed by Power Aire, Inc

(Band) Cylinder series Applicable bore size (mm) 200 40 180 160 32 140 50 20 25 63 80 100 125 CDV3, CDVS CE2, CNA CDL1 CDS1 BD1 -04M BD1 -05M BD1 -06M BD1 -08M BD1 -10M BS1 -125 BS1 -140 BS1 -160 BS1 -180 BS1 -200 BD1 -01M BD1 -02M BD1 -02 BD1 -04M RHC BMB2 -032 BMB2 -040 BMB1 -050 BMB1 -063 BMB1 -080 BMB1 -100 MDB 8-30-57 58 Technical Data 2: How to Mount and Move the Auto Switch Mounting

(Band) Cylinder series Applicable bore size (mm) 200 40 180 160 32 140 50 20 25 63 80 100 125 CDV3, CDVS CE2, CNA CDL1 CDS1 BD1 -04M BD1 -05M BD1 -06M BD1 -08M BD1 -10M BS1 -125 BS1 -140 BS1 -160 BS1 -180 BS1 -200 BD1 -01M BD1 -02M BD1 -02 BD1 -04M RHC BMB2 -032 BMB2 -040 BMB1 -050 BMB1 -063 BMB1 -080 BMB1 -100 MDB 8-30-57 58 Technical Data 2: How to Mount and Move the Auto Switch Mounting

Magnet: D (Built-in), Series: BA2 (with End Lock), Mounting: F (Front Flange), Tube Material: Aluminum Tube, Bore Size: 50mm, Port Thread: Rc, Stroke: 125mm, Rod Boot: w/o Gaiter w/Cushion Both Sides, Cushion: Air Cushion, Lock Position: H (Rear Locking), Release Type: N (Non-locking Type)

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: [Included] Presence (Only Rod Side), Cushion: Air cushion, Operating Pressure(MPa): 0.15 to 1.0, Specification: Built-in magnet, Port

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: [Included] Presence (Only Rod Side), Cushion: Air cushion, Operating Pressure(MPa): 0.15 to 1.0, Specification: Built-in magnet, Port

Models Standard strokes (mm) 32 40 50 63 MGP 25, 50, 75, 100, 125, 150, 175 200, 250, 300, 350, 400 M L Intermediate strokes (in 5mm increments) are produced by installing spacers of 5, 10, 15 and 20mm widths. When a special intermediate stroke body is needed, contact SMC.

Type Lube Non-lube Air-hydro 125 140 160 Bore size Nil N H Lube, Non-lube Air-hydro 125 140 160 180 200 250 300 125 mm 140 mm 160 mm 180 mm 200 mm 250 mm 300 mm 125 mm 140 mm 160 mm Mounting Bracket Part No. 125 140 160 180 200 250 300 Bore size (mm) For How to Order with auto switch, refer to page 6-9-7.

140 160 Note) 125 to 160 with auto switch type is not available.

(mm) Bore size Auto switch model Bore size (mm) Auto switch model 125 140 160 125 140 160 D-A9/A9V D-A9/A9V D-M9/M9V D-M9W/M9WV D-M9A/M9AV D-A5/A6 D-A59W D-F5/J5 D-F5NT D-F5W/J59W D-F5BAL/F59F 12 12.5 11.5 D-M9/M9V D-M9W/M9WV D-M9A/M9AV BS5-125 BS5-125 BS5-160 6 6.5 6.5 D-Z7/Z80 D-A3/A44 D-A5/A6 D-A59W 14 14.5 13 BT-12 BT-12 BT-16 10 10 10 17 17 17 D-Y59/Y69 D-Y7P/Y7PV D-Y7W/Y7WV D-Y7BA D-A3

140 160 Note) 125 to 160 with auto switch type is not available.

Rod Series CLS 125, 140, 160 How to Order CLS L 125 125 100 100 A93 Standard Type CDLS A93 A53 With Auto Switch L With auto switch Cylinder unit auto switch type Mounting brackets Number of auto switches B Basic type Tube material Nil Without auto switch L Foot type 2pcs.

D20Bore size MHS 3 D 50 32 to 125 Y59A Number of auto switch 2 pcs. 1 pc. n pcs. Nil S n Bore size Number of fingers 32 40 50 63 80 100 125 32 mm 40 mm 50 mm 63 mm 80 mm 100 mm 125 mm Auto switch Action 3 3 fingers Without auto switch (Built-in magnet) D Double acting Nil For the applicable auto switch model, refer to the table below.

IC circuit A56 5 V Reed switch Solid state switch A53 12 V Grommet Yes Relay, PLC 24 V A54 2-wire 100 V, 200 V Diagnosis indication (2-color) A59 W F59 3-wire (NPN) 5 V, 12 V IC circuit F5P 24 V 3-wire (PNP) J59 12 V 2-wire J51 100 V, 200 V Relay, PLC Yes Grommet F59 W 3-wire (NPN) 5 V, 12 V IC circuit Diagnosis indication (2-color) F5PW 3-wire (PNP) J59 W 24 V 2-wire F5BA

IC circuit A56 5 V Reed switch Solid state switch A53 12 V Grommet Yes Relay, PLC 24 V A54 2-wire 100 V, 200 V Diagnosis indication (2-color) A59 W F59 3-wire (NPN) 5 V, 12 V IC circuit F5P 24 V 3-wire (PNP) J59 12 V 2-wire J51 100 V, 200 V Relay, PLC Yes Grommet F59 W 3-wire (NPN) 5 V, 12 V IC circuit Diagnosis indication (2-color) F5PW 3-wire (PNP) J59 W 24 V 2-wire F5BA

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, TIE ROD, END LOCK, ACTUATOR, CBA1/CBA2 TIE-ROD CYL END LOCK, NC, CBA1 50MM OTHERS (COMBO), 7.04681 lb