Accuracy: Basic Type, Size: 63, Motor Mounting Position: In-line, Motor Type: Mounting Type X, Lead Screw: B [LEY25, 6mm; LEY32, 8mm, (10); LEY63, 10mm], Stroke: 350mm, Dust/Drip Proof: Size 25, 32: w/o Enclosure; Size 63: IP5x, Dust Proof Specification, Rod End Thread: Rod End Female Thread, Mounting: Rod Flange
Accuracy: Basic Type, Size: 63, Motor Mounting Position: Top Mounting, Motor Type: Mounting Type Z, Lead Screw: A [LEY25, 12mm; LEY32, 16mm, (20); LEY63, 20mm], Stroke: 350mm, Dust/Drip Proof: Size 25, 32: w/o Enclosure; Size 63: IP5x, Dust Proof Specification, Rod End Thread: Rod End Female Thread, Mounting: Rod Flange
Magnet: Built-in Magnet, Mounting: Front Flange, Bore Size: 40mm, Port Thread: Rc, Stroke: 350mm, Low Friction Direction: Pressure at Head Side, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -
Magnet: Built-in Magnet, Mounting: Foot, Bore Size: 80mm, Port Thread: Rc, Stroke: 350mm, Low Friction Direction: Pressure at Head Side, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -
Magnet: Built-in Magnet, Mounting: Center Trunnion, Bore Size: 40mm, Port Thread: Rc, Stroke: 350mm, Low Friction Direction: Pressure at Head Side, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -
Magnet: None, Mounting: Double Clevis, Bore Size: 100mm, Port Thread: Rc, Stroke: 350mm, Low Friction Direction: Pressure at Head Side, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -
Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 350, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 350, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure
Cylinder (Tube) Inner Diameter(φ): 140, Stroke(mm): 350, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure
Cylinder (Tube) Inner Diameter(φ): 160, Stroke(mm): 350, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure
Cylinder (Tube) Inner Diameter(φ): 160, Stroke(mm): 350, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 350, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Plate Cylinder, Additional Function: Standard, Environment, Applications: Low Friction (Internal Resistance), Cushion: None, Operating Pressure(MPa): 0.01 to 0.7, Specification: Built-in magnet, Port thread type:
Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 350, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Others, Environment, Applications: Standard, Cushion: Air cushion, Specification: Without magnet, Port thread type: Rc, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number of the switches: N/A, Type of Auto
Magnet: None, Series: Standard, Mounting: Basic Style, Low Friction: Low Friction, Tube Material: Aluminum Tube, Bore Size: Ø80, Port Thread: Rc, Stroke: 350mm, Low Friction Direction: Head Side at Pressure, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -
Magnet: None, Series: Standard, Mounting: Center Trunnion, Low Friction: Low Friction, Tube Material: Aluminum Tube, Bore Size: Ø50, Port Thread: Rc, Stroke: 350mm, Low Friction Direction: Head Side at Pressure, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -
Magnet: None, Series: Standard, Mounting: Basic Style, Low Friction: Low Friction, Tube Material: Steel Tube, Bore Size: Ø40, Port Thread: Rc, Stroke: 350mm, Low Friction Direction: Head Side at Pressure, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -
Magnet: None, Series: Standard, Mounting: Center Trunnion, Low Friction: Low Friction, Tube Material: Aluminum Tube, Bore Size: Ø63, Port Thread: Rc, Stroke: 350mm, Low Friction Direction: Head Side at Pressure, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -
Magnet: Built-in, Series: Standard, Mounting: Double Clevis, Low Friction: Low Friction, Tube Material: Aluminum Tube, Bore Size: Ø100, Port Thread: Rc, Stroke: 350mm, Low Friction Direction: Head Side at Pressure, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -
Magnet: None, Series: Standard, Mounting: Center Trunnion, Low Friction: Low Friction, Tube Material: Aluminum Tube, Bore Size: Ø50, Port Thread: NPT, Stroke: 350mm, Low Friction Direction: Head Side at Pressure, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -
The MB series medium duty tie rod cylinder offers an improved design that enhances cylinder operation and ease of use. The standard air cushion utilizes a floating cushion seal to eliminate piston rod bouncing. The cushion volume has been elevated permitting about 30% more allowable kinetic energy absorption. The port and captive cushion adjustment valve are located on the same side of cap