specifications Double wiring specifications Double wiring specifications 09 02 04 02 12 02 04 02 9 stations 4 stations 12 stations 4 stations 2 stations 2 stations 2 stations 2 stations (2) (2) (2) (2) Specified layout (Up to 8 solenoids possible.)

With One-touch fitting Port size For low speed control M5 U10/32 01 02 M5 x 0.8 10-32 UNF 1/8 1/4 Thread type Nil Metric thread (M5) Unified thread (10-32 UNF) R NPT N Needle Valve/Flow Characteristics AS1201FM, AS1211FM AS1301FM, AS1311FM AS2201FM-01, AS2211FM-01 AS2301FM-01, AS2311FM-01 AS2201FM-02, AS2211FM-02 AS2301FM-02, AS2311FM-02 0.8 Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa

With One-touch fitting Port size For low speed control M5 U10/32 01 02 M5 x 0.8 10-32UNF 1/8 1/4 Thread type Nil Metric thread (M5) Unified thread (10-32UNF) R NPT N Needle Valve/Flow Rate Characteristics AS1201FM, AS1211FM AS1301FM, AS1311FM AS2201FM-01, AS2211FM-01 AS2301FM-01, AS2311FM-01 AS2201FM-02, AS2211FM-02 AS2301FM-02, AS2311FM-02 Upstream pressure 0.5MPa Upstream pressure 0.5MPa

AS1201FM, AS1211FM AS1301FM, AS1311FM AS2201FM-01, AS2211FM-01 AS2301FM-01, AS2311FM-01 AS2201FM-02, AS2211FM-02 AS2301FM-02, AS2311FM-02 Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa 10 20 50 Flow rate (L/min (ANR)) Flow rate (L/min (ANR)) Flow rate (L/min (ANR)) 40 30 5 10 20 10 0 5 0 5 20 10 10 0 10 Number of needle rotations Number of needle rotations Number

AS2201F-01-06-X214 AS2301F-01-06-X214 RS H A AS2201F-01-06-X214 AS2301F-01-06-X214 AS2201F-02-06-X214 AS2301F-02-06-X214 RZQ 3. When disassembling to replace the seals and wear ring, refer to the separate disassembly instructions. AS3201F-02-08-X214 AS3301F-02-08-X214 AS3201F-02-08-X214 AS3301F-02-08-X214 MI W S 4.

EX: NVM121-N01-01S NVM131-01-01 NVM131-01-35 NVMl51-01-35 NVMl21-01-02 NVM13t-01-02 NVM120-N01-00 130-N01-00 F.O.F.'lbs.

EX: NVM121-N01-01S NVM131-01-01 NVM131-01-35 NVMl51-01-35 NVMl21-01-02 NVM13t-01-02 NVM120-N01-00 130-N01-00 F.O.F.'lbs.

For driver of 200W to 400W, regenerative resistor is not used. 02:LEC-MR-RB-032 03:LEC-MR-RB-12 Selection of regenerative option 00: Regenerative option is not used For servo amplifier of 100W, regenerative resistor is not used. For servo amplifier of 200 to 400W, built-in regenerative resistor is used. 02: MR-RB032 03: MR-RB12 4 6 4.

In addition, the facility water return temperature is 60C at max. 10min 4min Max. 2min Operating time 1min 30s 20s Circulating Fluid 10s 5s Caution 1. Avoid oil or other foreign matter entering the circulating fluid. 2s Min. 1s 0.5s 2. When water is used as a circulating fluid, use tap water that conforms to the appropriate water quality standards.

Poloneza 89, PL-02-826 Warszawa Portugal SMC Sucursal Portugal, S.A. (351) 22 616 6570 Rua De Eng Ferrerira Dias 452 4100-246,Porto Romania SMC Romania S.r.l. (40)21-3205111 Str.

Tap water: Standard of The Japan Refregeration And Air Conditioning Industry Association (JRA GL-02-1994) 15% ethylene glycol aqueous solution: diluted by tap water in condition above without any additives such as antiseptics.

Poloneza 89, PL-02-826 Warszawa Portugal SMC Sucursal Portugal, S.A. (351) 22 616 6570 Rua De Eng Ferrerira Dias 452 4100-246,Porto Romania SMC Romania S.r.l. (40)21-3205111 Str.

For 3 stations For remote I/O A1W DeviceNet PROFIBUS-DP CC-Link 16 For 16 stations A2W 0 Without SI unit Stations Ports 1, 3, 5 position Symbol 02 Stations 2 stations Note U D B U side (2 to 10 stations) D side (2 to 10 stations) Both sides (2 to 16 stations) Note 1) Double wiring specifications 08 02 8 stations 2 stations Note 2) Supply/Exhaust block assembly specification Specified

Check that a proper connection is established between the power cable and main breaker of this system. 02 Incorrect Phase Error FLT Stop The power phase rotation is wrong. The pressure of the refirigerant circuit exceeded the specified value.

Alarm1 Water Leak Detect FLT 01 Alarm2 Incorrect Phase Error FLT 02 Alarm5 Reservoir Low Level FLT 05 Alarm6 Reservoir Low Level WRN 06 Alarm7 Reservoir High Level WRN 07 Alarm8 Temp. Fuse Cutout FLT 08 Alarm9 Reservoir High Temp. FLT 09 Alarm10 Return High Temp WRN 10 Alarm11 Reservoir High Temp.

If it has a shorter operating time, there is a possibility of accidental breaker trip due to the internal motors inrush currents of this product. 4h 2h 1h 30min 20min 14min 10min 6min 4min 2min 1min 30s 20s Operating time Max. 10s 5s 2s Min. 1s 0.5s 0.2s 0.1s 0.05s 0.02s 0.01s 100 135 200 300 400 500 600700 1000 1500 2000 3000 4000 Current (% for breaker capacity) Operating characteristics

BA-01 BA-02 BA-32 NBA-088S NBA-106S BA-32 BGS1-032S BA-06 BA-05 BAF-04S BAF-06S BAF-05S [Mounting screws set made of stainless steel] The following set of mounting screws made of stainless steel is also available.

Tie-rod base SS5V 10 1 A2W W D 05 U 10S Cassette base SS5V 10 W U D 05 16S 1 A2W Clean series DIN rail length specified Enclosure IP67 Standard length Nil 3 Series For 3 stations Specify a longer rail than the standard length. 1 2 10-SV1000 10-SV2000 16 For 16 stations SI unit 0 Without SI unit DeviceNet/PROFIBUS DP/ EtherNet/IP A2W Valve stations P, E port location Symbol 02 Stations

For 3 stations 0 Without SI unit 16 DeviceNet/PROFIBUS DP/ CC-Link/EtherNet/IP For 16 stations A2W Valve stations P, E port location Stations 2 stations Note Symbol 02 U D B U side (2 to 10 stations) D side (2 to 10 stations) Both sides (2 to 16 stations) (1) Double wiring specifications 08 02 8 stations 2 stations (2) Specified layout (up to 16 solenoids possible.)

1.02kgf/cm2j -O.1MPa 1MPa 11 O.2kgf/cm2j MPa, PSI kgflcm2. bar Unit setting mmHg, kPa, PSI kgflcm2 , bar MPa:O.01, PSI:1 kgf/cm2:O.1, bar:O.1 Min. setting range mmHg:10, kPa:2, PSI:O.2 kgf/cm2:O.02, bar:O.02 A variety of switch output modes Note1) J HysteresIs mode Adjustable (2digit or more) Adjustable (3digit or more) Applicable to a hysteresis mode, window comparator mode.and reversed