Features and the main differences/similarities of the refreshed AR10-A to AR40-A and AR20-B to AR60-B series are described below.
The features of AR-A series regulators are as follows. ① The flow rate characteristics (reduced pressure drop) have been improved. ② The product has been whitened. ③ A backflow function has been added.
Applicable model AR30 AR40 AR40-06 AR50 AR60 Option Note 4) Note 4) Note 1) AR30P-270AS AR40P-270AS AR40P-270AS AR50P-270AS AR50P-270AS Bracket assembly Note 5) Note 5) AR30P-260S AR40P-260S AR40P-260S Set nut G36-10-01 G46-10-02 G46-10-02 G46-10-02 G46-10-02 Round Square embedded type Round Square embedded type 1MPa Note 2) Note 3) Pressure gauge GC3-10AS GC3-10AS GC3-10AS GC3-10AS GC3
SOL.A 8A () (+) Station 8 SOL.B 1A COM 2A 3A 4A 5A 6A 7A 8A 9A 10A 8B () (+) 1B 1A 2B 2A 3B 3A 4B 4A 5B 5A 6B 6A 7B 7A 8B 8A 9B 9A 10B 10A COM 1B 2B 3B 4B 5B 6B 7B 8B 9B 10B SOL.A 9A () (+) Station 9 SOL.B 9B () (+) SOL.A 10A () (+) Station 10 SOL.B 10B () (+) Note) When using the negative COM specification, use valves for negative COM. (+) () COM Note) Negative COM spec.
B 8B () (+) Station 8 1A COM 2A 3A 4A 5A 6A 7A 8A 9A 10A 1B 1A 2B 2A 3B 3A 4B 4A 5B 5A 6B 6A 7B 7A 8B 8A 9B 9A 10B 10A COM 1B 2B 3B 4B 5B 6B 7B 8B 9B 10B SOL. A 9A () (+) SOL. B 9B () (+) Station 9 SOL. A 10A () (+) SOL. B 10B () (+) Station 10 Note) When using the negative COM. specification for VQC1000/2000, use valves for negative COM. (+) () COM. Positive COM.
SOL.A 3A SOL.B 3B Station 3 SOL.A 4A SOL.B 4B Station 4 SOL.A 5A 10A COM 10B SOL.B 5B Station 5 SOL.A 6A SOL.B 6B Station 6 SOL.A 7A 1A COM 2A 3A 4A 5A 6A 7A 8A 9A 10A 1B 1A 2B 2A 3B 3A 4B 4A 5B 5A 6B 6A 7B 7A 8B 8A 9B 9A 10B 10A COM 1B 2B 3B 4B 5B 6B 7B 8B 9B 10B SOL.B 7B Station 7 Double wiring (connected to SOL. A and SOL.
SOL.A 8A () (+) 1A COM 2A 3A 4A 5A 6A 7A 8A 9A 10A SOL.B 8B () (+) 8 stations 1B 1A 2B 2A 3B 3A 4B 4A 5B 5A 6B 6A 7B 7A 8B 8A 9B 9A 10B 10A COM 1B 2B 3B 4B 5B 6B 7B 8B 9B 10B SOL.A 9A () (+) SOL.B 9B () (+) 9 stations SOL.A 10A () (+) SOL.B 10B () (+) 10 stations (+) () COM Note) There is no polarity. It can also be used as a negative common.
SOL.B 7B ( ) ( + ) 7 stations SOL.A 8A ( ) ( + ) SOL.B 8B ( ) ( + ) 8 stations 1A COM 2A 3A 4A 5A 6A 7A 8A 9A 10A 1B 1A 2B 2A 3B 3A 4B 4A 5B 5A 6B 6A 7B 7A 8B 8A 9B 9A 10B 10A COM 1B 2B 3B 4B 5B 6B 7B 8B 9B 10B SOL.A 9A ( ) ( + ) SOL.B 9B ( ) ( + ) 9 stations SOL.A 10A ( ) ( + ) SOL.B 10B ( ) ( + ) 10 stations ( + ) ( ) COM Note) There is no polarity.
B 8B () (+) Station 8 1A COM 2A 3A 4A 5A 6A 7A 8A 9A 10A 1B 1A 2B 2A 3B 3A 4B 4A 5B 5A 6B 6A 7B 7A 8B 8A 9B 9A 10B 10A COM 1B 2B 3B 4B 5B 6B 7B 8B 9B 10B SOL. A 9A () (+) SOL. B 9B () (+) Station 9 SOL. A 10A () (+) Note) There is no polarity. This device can also be used as a negative common. SOL.
SOL.B 7B ( ) ( + ) 7 stations SOL.A 8A ( ) ( + ) SOL.B 8B ( ) ( + ) 8 stations 1A COM 2A 3A 4A 5A 6A 7A 8A 9A 10A 1B 1A 2B 2A 3B 3A 4B 4A 5B 5A 6B 6A 7B 7A 8B 8A 9B 9A 10B 10A COM 1B 2B 3B 4B 5B 6B 7B 8B 9B 10B SOL.A 9A ( ) ( + ) SOL.B 9B ( ) ( + ) 9 stations SOL.A 10A ( ) ( + ) SOL.B 10B ( ) ( + ) 10 stations ( + ) ( ) COM Note) There is no polarity.
A 9A () (+) 1B 1A 2B 2A 3B 3A 4B 4A 5B 5A 6B 6A 7B 7A 8B 8A 9B 9A 10B 10A COM 1B 2B 3B 4B 5B 6B 7B 8B 9B 10B SOL. B 9B () (+) Station 9 SOL. A 10A () (+) Note) There is no polarity. This device can also be used as a negative common. SOL.
JSXFA(E, F, H)-10-B-A JSXF-10B-A-KT JSXFA(E, F)-14-BJSXF-14B-KT JSXF-14B-KT2 AN30-03 (14R, 14F), AN30-N03 (14N) Disassembly/Assembly Procedure Caution Port size: 06, 10 Port size: 14 1.
Cost effective and clean looking, series AR regulators offer various pressure range settings to accommodate most applications. The locking adjustment knob prevents accidental setting changes. The modular design of the AR series connects with other SMC air preparation equipment.Modular type regulator, Optional embedded pressure gauge , Available with built-in backflow mechanism , Knob is made
Table (3) Guide block L3 L3 End face L3 (mm) 19 15 15 15 15 15 Model MXP10-10B MXP10-20B MXP12-15B MXP12-25B MXP16-20B MXP16-30B Tightening torque (Nm) Model MXP10 MXP12 MXP16 1.67 8-8-5 5 Series MXP Model Selection Model Selection Step Formula/Data Selection Example Operating Conditions 1 Enumerate the operating conditions considering the mounting position and workpiece configuration.
Body Size: 60, Backflow: w/o Backflow Function, Thread: Rc, Port Size: 10 (1), Options: w/o Mounting Option, Set Pressure: 0.05 to 0.85 MPa Setting, Exhaust Mechanism: Relieving Type, Flow Direction: Left to Right, Knob: Downward, Pressure Units: Unit on Product Label: MPa, Pressure Gauge in SI Units: MPa
Body Size: 60, Backflow: w/o Backflow Function, Thread: Rc, Port Size: 1, Options: w/o Mounting Option, Set Pressure: 0.05 to 0.85 MPa Setting, Exhaust Mechanism: Relieving Type, Flow Direction: Left to Right, Knob: Downward, Pressure Units: Unit on Product Label: MPa, Pressure Gauge in SI Units: MPa, Made to Order: -
Note 2) Assembly of a bracket and set nuts (90-AR30 and 90-AR40, 90-AR25(K) to 90-AR40(K)) Including 2 mounting screws for the 90-AR50(K) and 90-AR60(K). Note 3) The only difference from the standard specifications is the adjusting spring for the regulator. It does not restrict the setting of 0.2 MPa or more. Note 4) : For thread type: NPT.
AR10-A: Rc1/16
AR20-A to AR40-A, AR20(K)-B to AR60(K)-B, and AR20(K)-D to AR40(K)-D: Rc1/8
Old AR10: Rc1/16
Old AR20(K) to AR30(K): Rc1/8
Old AR40(K) to AR60(K): Rc1/4
Old AR1000: Rc1/16
Old AR2000 to AR3000: Rc1/8
Old AR4000 to AR6000: Rc1/4
AR10-A: Rc1/16
AR20-A to AR40-A, AR20(K)-B to AR60(K)-B, and AR20(K)-D to AR40(K)-D: Rc1/8
Old AR10: Rc1/16
Old AR20(K) to AR30(K): Rc1/8
Old AR40(K) to AR60(K): Rc1/4
Old AR1000: Rc1/16
Old AR2000 to AR3000: Rc1/8
Old AR4000 to AR6000: Rc1/4
. +0.07 0 IH2-03B IH2-04B IH2-05B IH2-06B IH2-08B IH2-10B IH2-03B IH2-05C IH2-06C IH2-06B IH2-10C 25 16 76 60 25 32 M16 x 1.5 26 M5 x 0.8 16 CHQ +0.07 0 25 16 76 60 25 32 M20 x 1.5 31 M5 x 0.8 16 F J E +0.084 0 31.5 20 90 70 30 40 M24 x 1.5 36 M5 x 0.8 20 dH10 CHK B-series +0.1 0 40 31.5 145 115 45 60 M30 x 1.5 50 M6 x 1.0 30 +0.1 0 40 31.5 145 115 45 60 M39 x 1.5 61 M6 x 1.0 30 CHN H 0.1
Refer to page 562 for details. () (+) 8A Station 8 SOL.B () (+) 8B SOL.A () (+) 9A Station 9 SOL.B () (+) 9B SOL.A () (+) 10A Station 10 SOL.B () (+) 10B 6 (+) () COM. Note) Positive COM spec. Negative COM spec. Step 3. Mounting the terminal block cover Securely tighten the screws after confirming that the gasket is installed correctly.