Contact P/A if an application under such conditions cannot be avoided. 10 One-touch fitting 10 One-touch fitting Parts list Material AFM20 Zinc die-cast AFM30, AFM40, AFM40-06 Aluminum die-cast Note Description No. Body 1 Platinum silver Replacement parts Part no. No.
Note 5) As for other commercial items, there are some cases it is not able to connect due to tolerance of dimensions. 2R Fixed side At a temperature of 20C, bend the tubing into a U shape. Fix one end and gradually move the other end closer. Measure 2R at the point where the outside diameters rate of change is 5%.
Min. Dripping Flow Rate(l/min): 190, Oil Storage Capacity(cm3): 135, Case: [Resin] Polycarbonate Case, Inlet Side Connection Type: Rc, Inlet Side Plumbing Thread Nominal: 1, Outlet Side Connection Type: Rc, Outlet Side Plumbing Thread Nominal: 1, Drain Exhaust: [Not Provided] No Drain Cock, Flow Direction: [Right] From Left to Right, Size of Body: 50, Accessory: Without optional
Body Size: 50, Thread: Rc (Rc: for Sizes 20~60; M5: for Size 10), Port Size: 10 (1), Mounting: None, Semi-Standard, Body Size 10: Standard, Semi-Standard, Body Size 20: Standard, Semi-Standard, Body Size 30, 40, 50 & 60: Standard
Please note that the refraction value is not warranted because of the value when 2R is measured by the method in the left figure if the tubing is bent or flattened, etc. At a temperature of 20C, bend the tubing into a U shape. Fix one end and gradually move the other end closer. Measure 2R at the point where the outside diameter's rate of change is 10%.
Printing/Fluid Print code Fluid SMC TS 0604 SOFTNYLON 6 x 4 SMC TS 0604 SOFTNYLON 6 x 4 Previous Air NEW Air/Water How to Order Length per roll Color How to measure the minimum bending radius 20 TS0604 W 2R Symbol Length Symbol Color At a temperature of 20C, bend the tubing into a U shape. Fix one end and gradually move the other end closer.
QCR: When the internal volume of a rotary actuator varies depending on the A and B ports, use formula (1). P + 0.1 0.1 QCR = V x x 10-. Formula (1) P + 0.1 0.1 Formula QC2 = QC x n x Number of actuators x Reserve factor . Formula (5) QCR = 2V x x 10-. Formula (2) P 0.1 QCP = 2 x a x L x x 10-.
Class Size combination Applicable tubing size (mm) 4 x 3 3 x 2 6 x 4 4 x 3 6 x 4 4 x 3 10 x 8 8 x 6 6 x 4 10 x 8 8 x 6 6 x 4 12 x 10 10 x 8 12 x 10 10 x 8 19 x 16 12 x 10 19 x 16 12 x 10 25 x 22 19 x 16 25 x 22 19 x 16 Connection threads Symbol 1 2 2 2 2 2 2 3 3 3 3 4 4 4 4 5 5 5 5 6 6 6 6 Connection threads A A B C D E F A B C D A B C D A B C D A B C D Applicable tubing size (inch) No.
I = I + IA kgm (m to m : Mass of I to I kg) D Calculation example When d1 = 0.1m, d = 0.05m, D = 0.04m, a = 0.04m, b = 0.02m m = 1kg, m = 0.4kg, m = 0.5kg, m = 0.2kg, Gear tooth ratio = 2 Cylinder: I I = 0.2 x = 0.03 x 10 -3kg m I = 1 x = 1.25 x 10 -3 kgm 0.1 8 0.04+0.02 12 b IB = (0.13 + 0.1 + 0.03) x 10 -3= 0.26 x 10 -3 kgm 0.05 8 I = 0.4 x = 0.13 x 10 -3 kgm a IA = 2 x 0.26 x 10 -3 = 1.04
Fluid 10-12 10-11 10-10 10-9 10-8 10-7 10-6 10-5 10-4 10-3 10-2 10-1 1 101 102 103 104 105 106 107 108 109 Pa 1) Type of fluid Vacuum piping direction: if the system uses a vacuum pump, we ask that you install the vacuum pump on the secondary side. Also, install a filter on the primary side, and be careful that no foreign material is picked up.
In principle, this function counts each time there is a rise or fall in either of the A or B phase pulses. 2 1 Amplification/ Interpolation circuit Counter A phase B phase Magnetic resistance element Piston rod Magnet Count 1 2 3 4 5 6 7 8 9 10 .
I = I + IA kgm (m to m : Mass of I to I kg) D Calculation example When d1 = 0.1m, d = 0.05m, D = 0.04m, a = 0.04m, b = 0.02m m = 1kg, m = 0.4kg, m = 0.5kg, m = 0.2kg, Gear tooth ratio = 2 Cylinder: I I = 0.2 x = 0.03 x 10 -3kg m I = 1 x = 1.25 x 10 -3 kgm 0.1 8 0.04+0.02 12 b IB = (0.13 + 0.1 + 0.03) x 10 -3= 0.26 x 10 -3 kgm 0.05 8 I = 0.4 x = 0.13 x 10 -3 kgm a IA = 2 x 0.26 x 10 -3 = 1.04
I1 = 0.03 x (0.02 + 0.01)/12 = 1.25 x 10-kgm I2 = 0.006 x (0.005 + 0.005)/12 + 0.006 x 0.007 = 0.32 x 10-kgm I = 1.25 x 10+ 0.32 x 10-6 I1 = m x (a + b)/12 I2 = m x (a + b)/12 + m x H I = I1 + I2 Inertial moment = 1.57 x 10-kgm Kinetic energy 6 1/2 x I x Allowable energy = 2 /t (: Terminal angular velocity) : Rotation angle (rad) 1/2 x 1.57 x 10-6 x (2 x ( /2)/0.2) Confirm that the load's
I1 = 0.03 x (0.02 + 0.01)/12 = 1.25 x 10-kgm I2 = 0.006 x (0.005 + 0.005)/12 + 0.006 x 0.007 = 0.32 x 10-kgm I = 1.25 x 10+ 0.32 x 10-6 I1 = m x (a + b)/12 I2 = m x (a + b)/12 + m x H I = I1 + I2 Inertial moment = 1.57 x 10-kgm Kinetic energy 6 1/2 x I x Allowable energy = 2 /t (: Terminal angular velocity) : Rotation angle (rad) 1/2 x 1.57 x 10-6 x (2 x ( /2)/0.2) Confirm that the load's
Size: 3/4, Thread: G, Port Size: 3/4, Accessory: None, Option 1: Metal Bowl, Option 2: Flow Direction: Right->Left
At a temperature of 20C bend the tubing into a U shape.
At a temperature of 20C bend the tubing into a U shape.
Caution indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury. Caution: Warning indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury. Warning: Danger : Danger indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury.
Min. bending radius (mm) 15 Note 3) Note 4) 20 35 60 95 100 130 Air, Inert gas: -20 to 200C Water: 0 to 100C (No freezing) Operating temperature 2R Material FEP (Fluorinated Ethylene Propylene Resin) At a temperature of 20C, bend the tubing into a U shape. Fix one end and gradually move the other end closer. Measure 2R at the point where the outside diameter's rate of change is 5%.