VFS Y 5 3 37 25 22 14 1 VS4 25 25 3/8-2 port 3, 5 port 1/4, 3/8 1 port 9 1/4, 3/8-2 port 2, 4 port 1/8 12 port 1/8 14 port VQ7 VV71-(M Connector type) EVS VFN 100 80 100 80 37 23 U-side 9 2n-1/4, 3/8 14 9 U-side 15 PE port Indicator light Manual override R 4.5 R 4.5 53.5 53.5 9 9 38 9 B B 20 14 12 P = 43 A P = 43 PA 23 A A B B 14 12 A PA PA L1 L2 L2 L1 B B B 14 12 A A A A B 14 A A PA B B
H F G JIS Symbol (A) Lockable at the time of exhaust E 2 C D 1 3 (P) (R) Effective area mm2 (Cv) Model Port Size EXH 1/8 1/4 3/8 IN, OUT 1/4 3/8 1/2 IN to OUT 14 (0.76) 31 (1.68) 55 (2.98) OUT to EXH 16 (0.87) 29 (1.57) 42 (2.28) VHS20 VHS30 VHS40 A Paint color (Standard) Handle: Red Body: Platinum silver Use an air filter on the IN side for operating protection.
Note 8) Note 8) Note 8) Note 8) Note 8) Note 8) AV Note 4) Refer to Chemical Data on page 287 when selecting a case material.
Note 8) Note 8) Note 8) Note 8) Note 8) AG (Select wiring bottom entry when the semi-standard Y is chosen simultaneously.)
HRX-OM-W004-H Operation Manual Communication function Thermo-chiller Air-Cooled Water-Cooled refrigerated type refrigerated type HRR010-A-10HRR012-A-10HRR018-A-10HRR010-A-20HRR012-A-20HRR018-A-20HRR024-A-20HRR030-A-20HRR050-A-20HRR050-A-40HRR010-W-10HRR012-W-10HRR018-W-10HRR010-W-20HRR012-W-20HRR018-W-20HRR024-W-20HRR030-W-20HRR050-W-20HRR050-W-40Keep this manual available whenever necessary
40 A 4 cores x 8 mm2 (4 cores x AWG8) (Including grounding cable) R8-5 HRSH250--20 50 A 4 cores x 8 mm2 (4 cores x AWG8) (Including grounding cable) R8-5 M5 A HRSH100--40 20 A 3 x 5.5 mm2 (3 x AWG10) (Power supply) 1 x 14 mm2 (1 x AWG6) (Grounding cable) R5.5-5 (Power supply) R14-5 (Grounding cable) HRSH150--40 HRSH200--40 HRSH250--40 3-phase 380 to 415 VAC (50/60 Hz) 30 A Note) An example
Cable size Crimped terminal on the thermo-chiller side Applicable model HRS100-A -20HRS100-W -204 cores x 5.5 mm2 (4 cores x AWG10) (Including grounding cable R5.5-5) R5.5-5 3-phase 200 VAC (50 Hz) 3-phase 200 to 230 VAC (60 Hz) 30 A M5 HRS150-A -20HRS150-W -2040 A 4 cores x 8 mm2 (4 cores x AWG8) (Including grounding cable R8-5) R8-5 A HRS100-A -40HRS100-W -403-phase 380 to 415 VAC (50/60
If the actual flow rate is lower than this, install a bypass piping. Note 8) To be prepared by user. A specified earth leakage breaker is installed for option B [With earth leakage breaker] and B1 [With earth leakage breaker with handle].
30 20 Applicable earth Note 8) Sensitivity of leak current mA 30 Rated operating current Note 5) A 15 8 Rated power consumption Note 5) kW (kVA) 4.6 (5.2) 5.0 (5.6) Noise level (Front 1 m/Height 1 m) Note 5) dB (A) 66 Accessories Alarm code list stickers 2 pcs.
No anchor bolt is included. 77 A HRS090 Series Standard Type Cooling Capacity HRS090-A-20/40 (50 Hz) HRS090-A-20/40 (60 Hz) 12 12 10 10 Ambient temperature 32C Ambient temperature 32C Cooling capacity [kW] Cooling capacity [kW] 8 8 Ambient temperature 40C Ambient temperature 40C 6 6 4 4 Ambient temperature 45C Ambient temperature 45C 2 2 0 0 5 10 15 20 25 30 35 Circulating fluid temperature
x Depth 580 HRSE018-A-23 HRSE024-A-23 HRSE012-A-23-T 48 Height 790 x Width 470 x Depth 580 HRSE018-A-23-T HRSE024-A-23-T IDH Selection Warning 1.
Min. Dripping Flow Rate(l/min): 30, Oil Storage Capacity(cm3): 55, Case: [Resin] Polycarbonate Case, Inlet Side Connection Type: Rc, Inlet Side Plumbing Thread Nominal: 1/4, Outlet Side Connection Type: Rc, Outlet Side Plumbing Thread Nominal: 1/4, Drain Exhaust: [Not Provided] No Drain Cock, Flow Direction: [Right] From Left to Right, Size of Body: 30, Accessory: With Bracket,
Body Size: 30, Thread: Rc (Rc: for Sizes 20~60; M5: for Size 10), Port Size: 02 (1/4), Mounting: B (Bracket), Semi-Standard, Body Size 10: Standard, Semi-Standard, Body Size 20: Standard, Semi-Standard, Body Size 30, 40, 50 & 60: Standard
25 25 X (PE) port 1/8 A, B port 2-/4, 3/8 9 1/8 R1, R2 port 2-3/8 P port 1/4, 3/8 Y(PE) port 2 position double : VQ7-6-FG-D double (Reverse pressure): VQ7-6-YZ-D 3 position closed center : VQ7-6-FHG-D exhaust center : VQ7-6-FJG-D pressure center: VQ7-6-FIG-D 155 145 68.5 86.5 76.5 68.5 50 50 50 50 13 (A port) 13 (B port) 13 (A port) 13 (B port) Manual override Manual override A B A B B B
25 25 X (PE) port 1/8 A, B port 2-/4, 3/8 9 1/8 R1, R2 port 2-3/8 P port 1/4, 3/8 Y(PE) port 2 position double : VQ7-6-FG-D double (Reverse pressure): VQ7-6-YZ-D 3 position closed center : VQ7-6-FHG-D exhaust center : VQ7-6-FJG-D pressure center: VQ7-6-FIG-D 155 145 68.5 86.5 76.5 68.5 50 50 50 50 13 (A port) 13 (B port) 13 (A port) 13 (B port) Manual override Manual override A B A B B B
VFR PA A B VP4 L1 L2 B A A PA VZS A B SMC VFS PA A VS4 B VQ7 PA A L side R side (2n-1/8) EVS 38 D side VFN 3 68.5 (A, B port) 4n-1/4, 3/8 16 120.5 (Single) 44 155 (3 position) 145 (Double) 55 77.5 121 PA 14 PB 12 1 R 3 5 65 54 P 39 (Pilot pressure EXH port) 4-1/8 SMC 21 R2 R1 17 17 (P , R port) 6-3/8 26.5 26.5 L Dimension n: Stations 10 9 8 7 6 5 4 3 2 1 Formula L1 L1 = 43n + 64 494 451
Port size P, A, B R1, R2 Piping Model Side Side Bottom Bottom 1 4 3 8 VS7-1-A02 VS7-1-A03 VS7-1-B02 VS7-1-B03 3 8 1 4 3 8 3 8 1.19-8 Series VS7-6 Manifold Manifold: Series VV71 Standard Specifications SV ISO size q Series ISO size q 1 to 10 Manifold block size Applicable solenoid valve Number of stations SY 1 4 3 8 One-touch fitting: 12 1 4 3 8 A, B-port P, R1, R2-port One-touch fitting:
No.4 No.5 No.6 Output point COM A COM B COM C COM D OFF OFF OFF 64 16 16 16 16 OFF OFF ON 0 OFF ON OFF 16 8 8 OFF ON ON 24 8 8 8 ON OFF OFF 32 8 8 8 8 ON OFF ON 48 16 16 16 ON ON OFF Reserve ON ON ON : It cannot be set to 0 simultaneously for input and output point. -23No.EX-OMI0032-G 3.
No.4 No.5 No.6 Output point COM A COM B COM C COM D OFF OFF OFF 64 16 16 16 16 OFF OFF ON 0 OFF ON OFF 16 8 8 OFF ON ON 16 16 16 ON OFF OFF 32 8 8 8 8 ON OFF ON 32 16 16 ON ON OFF Reserve ON ON ON : It cannot be set to 0 simultaneously for input and output point. 3.
Output: 32 OFF ON ON 8 points for each 8 points for each of A to D of A to D 2.