Adjustable range of display value fine adjustment function C Peak/Bottom value display D Keylock function Prevents operation errors such as accidentally changing setting values This function constantly detects and updates the maximum (minimum) pressure when the power is supplied, and allows to hold the maximum (minimum) pressure value.
Rc1/8 M50.8 5 G1/4 A2L B2L URJ1/4 TSJ1/4 -82No.PS-OMU0008CN-D A -83No.PS-OMU0008CN-D C -84No.PS-OMU0008CN-D () 43.602 0.5~7 ()+ 43.602 0.5~7 -85No.PS-OMU0008CN-D () 1~5 -86No.PS-OMU0008CN-D ()+ 1~5 -87No.PS-OMU0008CN-D () 2 (n ) <> 31n +3.5n -1 -88No.PS-OMU0008CN-D <> -89No.PS-OMU0008CN-D () 2 (n ) <> 36n +4n -1 -90No.PS-OMU0008CN-D Revision history A [2018 7 ] B [2020 2 ] C [2021
Model Max. rated flow Model Max. rated flow [L/min] [L/min] PFM710--C/E 10 (5) PFM710--D/F 10 (5) PFM725--C/E 25 (12.5) PFM725--D/F 25 (12.5) PFM750--C/E 50 (25) PFM750--D/F 50 (25) PFM711--C/E 100 (50) PFM711--D/F 100 (50) : ( ): Fluid: CO2 : ( ): Fluid: CO2 Flow adjustment needle revolution Flow characteristics (reference value) -57No.PF-OMJ0006-J Pressure loss (at 350 [kPa]) -58No.PF-OMJ0006
Gasket Spacer Note 1) M5 and U10/32 type: Stainless steel Retaining ring for hole type C Note 1) M5 and U10/32 type: Stainless steel 737 AS1F-D Series Dimensions Elbow type L5 D3 H (Hexagon width across flats) Applicable tubing O.D. d A L4 D1 L3 M1 D2 T L1 L2 Metric Size Inch Size d T H D1 D2 D3 L1 L2 L3 L4 L5 AM1 A Weight (g) Model Model Weight (g) d T H D1 D2 D3 L1 L2 L3 L4 L5 M1 AS121F-U10
Adjustable range of display value fine adjustment function C Peak/Bottom value display D Key-lock function Prevents operation errors such as accidentally changing setting values This function constantly detects and updates the maximum (minimum) pressure when the power is supplied, and allows to hold the maximum (minimum) pressure value.
-01-D Meter-out M5 type U10/32 port AS3200-02-D Meter-out M5 type U10/32 port AS2210-01-D AS3210-02-D Component Parts No.
2 U seal Retaining ring for hole type C HNBR Tool steel y !
-J Panel mount adapter (Rear piping) ZS-35-C Panel cut-out dimensions -56No.PS-OMM0003-J Panel mount adapter (Bottom piping) ZS-35-B Panel cut-out dimensions -57No.PS-OMM0003-J Revision history A: Revision B: Modified errors in text C: Additional model D: Modified errors in text E: The following item is deleted "The Pressure switch is compulsory turned off for 4 seconds after power supplied
Both ends of the communication connection (the end nodes) need to be connected to the higher level computer. 2 2 R D R D 3 3 S D S D 5 5 S G S G Controller Master This product Do not connect any wire to other PIN numbers.
-1/2 -29No.PF-OMJ0016-J PFM5-F02L-1/2 -30No.PF-OMJ0016-J PFM5S-F02-1/2 -31No.PF-OMJ0016-J PFM5S-F02L-1/2 -32No.PF-OMJ0016-J PFM5-C/N-1/2 -33No.PF-OMJ0016-J PFM5-C/NL-1/2 -34No.PF-OMJ0016-J PFM5S-C/N-1/2 -35No.PF-OMJ0016-J PFM5S-C/NL-1/2 -36No.PF-OMJ0016-J Panel cut-out dimensions Flow adjustment valve A 0.5 None 54 0 0.5 With flow adjustment valve 74 0 1: These are the minimum dimensions
Table 3.8-2 RTU mode message frame Address c)Function d)Data e)Checksum a)Start b)Device (CRC) f)End T1-T2-T3-T4 XX XX XX XX XX XX T1-T2-T3-T4 a) Start In Modbus RTU mode, message frames are separated by a silent interval (noncommunication time).
Both ends of the communication connection (the end nodes) need to be connected to the higher level computer. 2 2 R D R D 3 3 S D S D 5 5 S G S G Master This product Do not connect any wire to other PIN numbers.
Q = qm x C x (T2 T1) x qv x C x iT 60 1 x 70 x 4.186 x 103 x 4.0 60 = = qm x C x (T2 T1) 860 Q = = 19535 [J/s] 19535 [W] = 19.5 [kW] x qv x 60 x C x iT 860 = Cooling capacity = Considering a safety factor of 20%, 19.5 [kW] x 1.2 = 23.4 [kW] 1 x 70 x 60 x 1.0 x 103 x 4.0 860 = Thermo-chiller T1: Outlet temperature Q: Heat generation amount 1680 [cal/h] 860 Users equipment = T = T2 T1
V : 150 [L] Cooled substance specific heat C : 1.0 x 103 [cal/(kgfC)] HRS 100/150 HRS 100/150 HRSH 090 HRSH Cooled substance temperature when cooling begins T0 : 30 [C] Cooled substance temperature after t hour Tt : 20 [C] Cooling temperature difference iT : 10 [C] (= T0 Tt) Cooling time it : 15 [min] Conversion factor: hours to minutes : 60 [min/h] Conversion factor: kcal/h to kW : 860
[L] Cooled substance specific heat C : 1.0 x 103 [cal/(kgfC)] Cooled substance temperature when cooling begins T0 : 30 [C] Cooled substance temperature after t hour Tt : 20 [C] Cooling temperature difference iT : 10 [C] (= T0 Tt) Cooling time it : 15 [min] Conversion factor: hours to minutes : 60 [min/h] Conversion factor: kcal/h to kW : 860 [(cal/h)/W] * Refer to the following for the
Q = qm x C x (T2 T1) x qv x C X T 1 x 35 x 4.186 x 103 x 3.0 60 = = 60 qm x C x (T2 T1) 860 Q = = 7325 [J/s] 7325 [W] = 7.3 [kW] x qv x 60 x C x T = Cooling capacity = Considering a safety factor of 20%, 7.3 [kW] x 1.2 = 860 8.8 [kW] 1 x 35 x 60 x 1.0 x 103 x 3.0 860 = Thermo-chiller qv: Circulating fluid flow rate Q: Heat generation amount T2: Return temperature Users equipment 7325
A C MTS D-F9W, D-M9 D-A93 D-A90, D-A96 D-M9V, D-F9WV Bore size (mm) CXSJ15 to 32 B D A 15.5 25.5 31.5 39 40 49 D 9.5 7 0 3 5 5.5 C 9.5 19.5 25.5 33 34 43 B 6 9 11 11.5 B 0.5 3 10 13 15 15.5 A 15.5 25.5 31.5 39 40 49 A 19.5 29.5 35.5 43 44 53 C 11.5 21.5 27.5 35 36 45 D 5.5 3 4 7 9 9.5 D 8 5.5 1.5 4.5 6.5 7 B 6 9 11 11.5 B 0.5 3 10 13 15 15.5 C 13.5 23.5 29.5 37 38 47 C 11 21 27 34.5 35.5
Booster regulator IN port C ARX EXH: C EXH: C Spare port Rc1/2 (A) AMR D D (A) (B) (B) OUT OUT 305 Tank OUT port Rc1/2 ARM 216 216 180 4 x 13 4 x 13 50 50 ARP Drain valve 100 100 Drain port Rc1/4 IR-A 200 200 400 700 678 IR Booster regulator model A B C D VBA20A 481 394 Rc3/8 VBA40A 520 429.8 Rc1/2 VBA22A 444 394 Rc3/8 469 VBA42A 477 429.8 Rc1/2 493 IRV The length may be longer than the
Connected to VBA20A, 40A VBAT20A1 Material: Carbon steel Connected to VBA22A, 42A Tank IN port Rc 1/2 Booster regulator IN port Booster regulator IN port Tank OUT port Rc 1/2 C C Spare port Rc 1/2 EXH: C EXH: C (A) (A) D (B) (B) OUT OUT 305 180 206 206 4 x 13 4 x 13 50 50 200 100 100 400 Drain port Rc 1/4 200 674 (mm) D Note) 469 493 685 A 481 520 444 477 B 394 429.8 394 429.8 C Rc 3/8
E C Padlock mounting position C D D Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com SUP SUP . A OUT IN A OUT IN 1 2 B 3 B EXH. EXH.