Facility having a small installation area (that can not vent the air naturally) Make a forced air exhaust vent on a wall at a high level and an air vent on a wall at a low level.
Min. Dripping Flow Rate(l/min): 15, Oil Storage Capacity(cm3): 25, Case: [Resin] Polycarbonate Case, Inlet Side Connection Type: Rc, Inlet Side Plumbing Thread Nominal: 1/8, Outlet Side Connection Type: Rc, Outlet Side Plumbing Thread Nominal: 1/8, Drain Exhaust: [Manual] With Drain Cock, Flow Direction: [Right] From Left to Right, Size of Body: 20, Accessory: With Bracket, Pressure
Body Size: 20, Thread: Rc (Rc: for Sizes 20~60; M5: for Size 10), Port Size: 1/8, Mounting: Bracket, Semi-Standard, Body Size 10: Metal Bowl, Semi-Standard, Body Size 20: Drain Cock, Semi-Standard, Body Size 30, 40, 50 & 60: Standard
Body Size: 20, Thread: Rc (Rc: for Sizes 20~60; M5: for Size 10), Port Size: 1/8, Mounting: Bracket, Semi-Standard, Body Size 10: Metal Bowl, Semi-Standard, Body Size 20: Standard, Semi-Standard, Body Size 30, 40, 50 & 60: Standard
Body Size: 20, Thread: Rc (Rc: for Sizes 20~60; M5: for Size 10), Port Size: 1/8, Mounting: Bracket, Semi-Standard, Body Size 10: Drain Cock, Semi-Standard, Body Size 20: Bowl Guard, Semi-Standard, Body Size 30, 40, 50 & 60: Standard
Body Size: 20, Thread: Rc (Rc: for Sizes 20~60; M5: for Size 10), Port Size: 01 (1/8), Mounting: B (Bracket), Semi-Standard, Body Size 10: 3 (Drain Cock), Semi-Standard, Body Size 20: Standard, Semi-Standard, Body Size 30, 40, 50 & 60: Standard
Body Size: 20, Thread: Rc (Rc: for Sizes 20~60; M5: for Size 10), Port Size: 01 (1/8), Mounting: B (Bracket), Semi-Standard, Body Size 10: 2 (Metal Bowl), Semi-Standard, Body Size 20: 3 (Drain Cock), Semi-Standard, Body Size 30, 40, 50 & 60: Standard
Body Size: 20, Thread: Rc (Rc: for Sizes 20~60; M5: for Size 10), Port Size: 01 (1/8), Mounting: B (Bracket), Semi-Standard, Body Size 10: 2 (Metal Bowl), Semi-Standard, Body Size 20: Standard, Semi-Standard, Body Size 30, 40, 50 & 60: Standard
Body Size: 20, Thread: Rc (Rc: for Sizes 20~60; M5: for Size 10), Port Size: 01 (1/8), Mounting: B (Bracket), Semi-Standard, Body Size 10: 3 (Drain Cock), Semi-Standard, Body Size 20: C (Bowl Guard), Semi-Standard, Body Size 30, 40, 50 & 60: Standard
HRS 100/150 Applicable model Dimension [mm] A B C HRSH250/300-A--A 916 536 1838 HRSH100/150/200-A--A 830 401 1538 HRSH100/150/200/250-W--A 570 1353 HRSH 090 HRSH HRSH HRSE HRZ HRZD HRW C HECR HEC 118 HEB A B HED HEA Option symbol With Earth Leakage Breaker B IDH HRSH 20 B With earth leakage breaker A leakage breaker is built in to automatically stop the supply power when it has short-circuit
HRS 100/150 HRS 100/150 Applicable model Dimension [mm] A B C HRS100/150-A-20/40-A 830 302 1552 HRS100/150-W-20/40-A 570 401 1353 C HRSH 090 HRSH 118 HRSE A B Option symbol With Earth Leakage Breaker B HRZ HRZD HRS 20 B With earth leakage breaker HRW A leakage breaker is built in to automatically stop the supply power when it has short-circuit, over current or electrical leakage.
(per unit) Applicable model A B C D HRSE012-AHRSE018-AHRSE024-A240 (335) 505 (540) HRW HRS-TK003 HECR HRSE012-A--T HRSE018-A--T HRSE024-A--T 240 (335) 555 (590) HEC HEB HED HEA IDH Anchor bolt (M8) D C (Prepared by user) Anti-quake bracket Material: Zinc steel plate Mounting view A B w Bypass Piping Set Note) To be mounted by user.
Applicable model Dimension in [mm] A B C HRS100/150-A-20/40-A 32.7 [830] 11.9 [302] 61.1 [1552] HRS100/150-W-20/40-A 22.4 [570] 15.8 [401] 53.5 [1353] C 118 A B Option symbol With Earth Leakage Breaker B HRS 20 B With earth leakage breaker A leakage breaker is built in to automatically stop the supply power when it has short-circuit, over current or electrical leakage.
x V x C x iT it m x C x (T0 Tt) it Q = = 1 x 150 x 4.186 x 103 x 10 900 = = 6977 [J/s] 7.0 [kW] m x C x (T0 Tt) it x 860 x V x 60 x C x iT it x 860 Q = = Cooling capacity = Considering a safety factor of 20%, 7.0 [kW] x 1.2 = 1 x 150 x 60 x 1.0 x 103 x 10 15 x 860 8.4 [kW] = Q x t: Heat capacity [kJ] Thermo-chiller Water bath 6977 [W] = 7.0 [kW] 20C Cooling capacity = Considering a safety
HRZ x V x C x iT it m x C x (T0 Tt) it Q = = HRZD 1 x 150 x 4.186 x 103 x 10 900 = = 6977 [J/s] 7.0 [kW] m x C x (T0 Tt) it x 860 x V x 60 x C x iT it x 860 HRW Q = = Cooling capacity = Considering a safety factor of 20%, 7.0 [kW] x 1.2 = HECR 1 x 150 x 60 x 1.0 x 103 x 10 15 x 860 8.4 [kW] = HEC Q x t: Heat capacity [kJ] Thermo-chiller Water bath 6977 [W] = 7.0 [kW] 20C HEB Cooling
Table 3.8-2 RTU mode message frame a)Start b)Slave Address c)Function d)Data e) Checksum (CRC) f)End T1-T2-T3-T4 XX XX XX XX XX XX T1-T2-T3-T4 a) Start In Modbus RTU mode, message frames are separated by a silent interval (non-communication time).
Table 3.8-2 RTU mode message frame a)Start b)Slave Address c)Function d)Data e) Checksum (CRC) f)End T1-T2-T3-T4 XX XX XX XX XX XX T1-T2-T3-T4 a) Start In Modbus RTU mode, message frames are separated by a silent interval (non-communication time).
Table 3.8-2 RTU mode message frame Address c)Function d)Data e)Checksum a)Start b)Device (CRC) f)End T1-T2-T3-T4 XX XX XX XX XX XX T1-T2-T3-T4 a) Start In Modbus RTU mode, message frames are separated by a silent interval (noncommunication time).
Remove a housing from a body by rotating 4 mounting screws counterclockwise with a hexagon wrench key. Hexagon wrench key Nominal: 5 2) Remove the valve guide. Hold the valve guide with a spanner on the spanner flat to rotate it counterclockwise and remove the valve guide. Spanner Nominal: 30 3) Remove the valve spring. 4) Remove the valve assembly.
Remove a housing from a body by rotating 4 mounting screws counterclockwise with a hexagon wrench key. Hexagon wrench key Nominal: 5 2) Remove the valve guide. Hold the valve guide with a spanner on the spanner flat to rotate it counterclockwise and remove the valve guide. Spanner Nominal: 30 3) Remove the valve spring. 4) Remove the valve assembly.