Type: 001 (Smart Lever Type), Pressure Gauge: 3 (1.0 MPa), Accessories: F (For Stroke 50 to 140mm w/Lever Unit), External Scale Plate: None, LCD Window: None, Connection, Air - Electric: M (Rc1/4 - M20x1.5)

Type: Smart Lever Type, Pressure Gauge: 1.0 MPa, Accessories: For Stroke 35 to 100mm w/Lever Unit, External Scale Plate: None, LCD Window: None, Connection, Air - Electric: NPT1/4 - M20x1.5, ATEX Temperature: -

Type: Smart Lever Type, Pressure Gauge: 1.0 MPa, Accessories: For Stroke 35 to 100mm w/Lever Unit, External Scale Plate: None, LCD Window: None, Connection, Air - Electric: Rc1/4 - M20x1.5, ATEX Temperature: -

Type: Smart Lever Type, Pressure Gauge: 1.0 MPa, Accessories: For Stroke 50 to 140mm w/Lever Unit, External Scale Plate: None, LCD Window: None, Connection, Air - Electric: Rc1/4 - M20x1.5, ATEX Temperature: -

Type: Relay Device, Type: Smart lever type, Specification: With Intrinsically safe explosion-proof (ATEX) + Output function + HART communication function, Pressure(MPa): 1.0, Fork lever type fitting: N/A, Lever unit: N/A, External scale plate: N/A, Body cover with window for LCD: Available, Air connection port: 1/4NPT, Conduit connection port: M20 × 1.5, Explosion-proof structure: ATEX Directive

Type: 001 (Smart Lever Type), Pressure Gauge: 3 (1.0 MPa), Accessories: F (For Stroke 50 to 140mm w/Lever Unit), External Scale Plate: None, LCD Window: None, Connection, Air - Electric: 1 (NPT1/4 - G1/2)

IP8000 E/P positioner is more compact than the IP6000 with improved visibility of the pressure indicator.  Other features include an improved enclosure protection IP65, interchangeable mounting, excellent shock and vibration performance, and a 1/2 split range available by simple span adjustment.  The IP200 cylinder positioner provides accurate and stable positioning of air cylinders.  The

"* (D r 1 How to Order fB(acket ln case of Type ol actuation I 2 position single 2 2 position double 3 3 position closed center 4 3 position exhaust center 5 3 position pressure center -: Without subplate M5: @@ With 10-32 Nom.

"* (D r 1 How to Order fB(acket ln case of Type ol actuation I 2 position single 2 2 position double 3 3 position closed center 4 3 position exhaust center 5 3 position pressure center -: Without subplate M5: @@ With 10-32 Nom.

Body poned type 3 Position Closed Center 3 Position Exhaust Center Closed Center ^"^ttrnEn I/\^ qft4hril-F!

The low profile design saves space and s2 reduces bending moments. b. 52 reuuuEs ucl|ulrg rl|ul|l -. iil _] 'lmproved accuracy with smooth operation J | . . ^ , " ^ Height is approximately 1/3 the size ol an equivalent Series MHZ2.

Type: 101 (Smart Rotary Type), Pressure Gauge: 3 (1.0 MPa), Accessories: D (Fork Lever-type Fitting S), External Scale Plate: None, LCD Window: W (Body w/LCD Window), Connection, Air - Electric: 2 (NPT1/4 - M20x1.5), ATEX Temperature: T6 [ATEX Temperature T6 (-20 to 60°C)]

Type: 101 (Smart Rotary Type), Pressure Gauge: 3 (1.0 MPa), Accessories: None (Standard), External Scale Plate: H (w/External Scale Plate), LCD Window: None, Connection, Air - Electric: 1 (NPT1/4 - G1/2), ATEX Temperature: T6 [ATEX Temperature T6 (-20 to 60°C)]

Type: Smart Rotary Type, Pressure Gauge: 1.0 MPa, Accessories: Fork Lever-type Fitting S, External Scale Plate: None, LCD Window: Body w/LCD Window, Connection, Air - Electric: NPT1/4 - M20x1.5, ATEX Temperature: T6 [ATEX Temperature T6 (-20 to 60°C)]

Type: Smart Rotary Type, Pressure Gauge: 1.0 MPa, Accessories: None (Standard), External Scale Plate: w/External Scale Plate, LCD Window: None, Connection, Air - Electric: NPT1/4 - G1/2, ATEX Temperature: T6 [ATEX Temperature T6 (-20 to 60°C)]

IP8000 E/P positioner is more compact than the IP6000 with improved visibility of the pressure indicator.  Other features include an improved enclosure protection IP65, interchangeable mounting, excellent shock and vibration performance, and a 1/2 split range available by simple span adjustment.  The IP200 cylinder positioner provides accurate and stable positioning of air cylinders.  The

IP8000 E/P positioner is more compact than the IP6000 with improved visibility of the pressure indicator.  Other features include an improved enclosure protection IP65, interchangeable mounting, excellent shock and vibration performance, and a 1/2 split range available by simple span adjustment.  The IP200 cylinder positioner provides accurate and stable positioning of air cylinders.  The

.; 52-SY when used with a safety barrier is certified and tested to the following ATEX classification: Ex II 2G EEx ia IIB T4..T6.; Three kinds of safety barriers are available.; The terminal box type (TT) is IP65 compliant.; Long life time (same as standard SY series).; This valve is only compatible with the legacy SY manifold; Body Ported.

.; 52-SY when used with a safety barrier is certified and tested to the following ATEX classification: Ex II 2G EEx ia IIB T4..T6.; Three kinds of safety barriers are available.; The terminal box type (TT) is IP65 compliant.; Long life time (same as standard SY series).; This valve is only compatible with the legacy SY manifold; Body Ported.

.; 52-SY when used with a safety barrier is certified and tested to the following ATEX classification: Ex II 2G EEx ia IIB T4..T6.; Three kinds of safety barriers are available.; The terminal box type (TT) is IP65 compliant.; Long life time (same as standard SY series).; Body Ported.