SOL.A 8A 1A COM 2A 3A 4A 5A 6A 7A 8A 9A 10A 8B Station 8 1B 1A 2B 2A 3B 3A 4B 4A 5B 5A 6B 6A 7B 7A 8B 8A 9B 9A 10B 10A COM 1B 2B 3B 4B 5B 6B 7B 8B 9B 10B SOL.B SOL.A 9A 9B Station 9 SOL.B SOL.A 10A 10B Station 10 SOL.B COM COM. 668 Base Mounted Plug-in Unit VQC5000 Series T VQC5000 Kit (Terminal block box kit) IP67 compliant VV5QC51 SV L2 SYJ L1 10 88.7 (7.1) 59.5 P = 41 SZ Indicator light
B 8B () (+) Station 8 1A COM 2A 3A 4A 5A 6A 7A 8A 9A 10A 1B 1A 2B 2A 3B 3A 4B 4A 5B 5A 6B 6A 7B 7A 8B 8A 9B 9A 10B 10A COM 1B 2B 3B 4B 5B 6B 7B 8B 9B 10B SOL. A 9A () (+) SOL. B 9B () (+) Station 9 SOL. A 10A () (+) Note) There is no polarity. This device can also be used as a negative common. SOL.
9B 10B 1B 1A 2B 2A 3B 3A 4B 4A 5B 5A 6B 6A 7B 7A 8B 8A 9B 9A Station 2 Station 3 Station 4 Station 5 10A COM 10B Station 6 1A COM 2A 3A 4A 5A 6A 7A 8A 9A 10A 1B 1A 2B 2A 3B 3A 4B 4A 5B 5A 6B 6A 7B 7A 8B 8A 9B 9A 10B 10A COM 1B 2B 3B 4B 5B 6B 7B 8B 9B 10B Station 7 Station 8 If alignment is not specified, the internal wiring will be double wiring (connected to SOL. a and SOL. b) regardless
SOL.A 8A () (+) 1A COM 2A 3A 4A 5A 6A 7A 8A 9A 10A SOL.B 8B () (+) 8 stations 1B 1A 2B 2A 3B 3A 4B 4A 5B 5A 6B 6A 7B 7A 8B 8A 9B 9A 10B 10A COM 1B 2B 3B 4B 5B 6B 7B 8B 9B 10B SOL.A 9A () (+) SOL.B 9B () (+) 9 stations SOL.A 10A () (+) SOL.B 10B () (+) 10 stations (+) () COM Note) There is no polarity. It can also be used as a negative common.
SOL.A 8A () (+) SOL.A 8A 1A COM 2A 3A 4A 5A 6A 7A 8A 9A 10A 1B 1A 2B 2A 3B 3A 4B 4A 5B 5A 6B 6A 7B 7A 8B 8A 9B 9A 10B 10A COM 1B 2B 3B 4B 5B 6B 7B 8B 9B 10B SOL.B 8B () (+) 8 stations SOL.B 8B SOL.A 9A () (+) SOL.A 9A SOL.B 9B () (+) 9 stations SOL.B 9B SOL.A 10A () (+) SOL.A 10A SOL.B 10B () (+) 10 stations SOL.B 10B (+) () COM COM Note) There is no polarity.
No-fuse breaker Fuse Current [A] (Note 2) Driver Voltage (Note 1) Class Current [A] Voltage Magnetic contactor Not using power factor improving Using power factor AC [V] AC [V] improving reactor reactor LECSA2-S1 30A frame 5A 30A frame 5A 10A LECSA2-S3/ LECSA1-S1 30A frame 10A 30A frame 10A 240V T 15A 300V S-N10 LECSA2-S4/ LECSA1-S3 30A frame 15A 30A frame 10A 20A Note 1.
B 8B () (+) Station 8 1A COM 2A 3A 4A 5A 6A 7A 8A 9A 10A 1B 1A 2B 2A 3B 3A 4B 4A 5B 5A 6B 6A 7B 7A 8B 8A 9B 9A 10B 10A COM 1B 2B 3B 4B 5B 6B 7B 8B 9B 10B SOL. A 9A () (+) SOL. B 9B () (+) Station 9 SOL. A 10A () (+) SOL. B 10B () (+) Station 10 Note) When using the negative COM. specification for VQC1000/2000, use valves for negative COM. (+) () COM. Positive COM.
10A 15A 20A 25A 32A 1 8 1 4 3 8 3 8 1 2 3 4 220 VAC 50/60 Hz Valve size 1 7 5 6 24 VDC 12 VDC B: Slotted locking type B (tool required) 7 240 VAC 50/60 Hz 15 (11) 2 Semi-standard For other rated voltages, please consult with SMC. 20 (14) 3 25 (16) 4 1 1 1 4 32 (22) 5 1 B 1 4 Flange 32F Nil: Non-locking push type 40A 1 1 2 Valve size 2 to 9 40 (28) 6 1 B 1 2 Flange 40F 2 50A 50 (33) 7 50F
B Grommet 100 VAC With surge voltage suppressor 12 One-touch fitting C 110 VAC G H J K 3/8 D 200 VAC 4 10A C37 N.C. 1/2 E 230 VAC 15 15A 3/8 Stainless steel B N.O. F 24 VDC 1/2 G DIN terminal 24 VDC L M 5 20A C37 N.C. With surge voltage suppressor 3/4 20 H 100 VAC C N.O. Stainless steel J 110 VAC 6 25A N.C. N P C37 Stainless steel 25 1 K 200 VAC D N.O. L 230 VAC 7 32A N.C.
Note) A: Non-locking push type A (projecting) 1 6A 8A 10A 10A 15A 20A 25A 32A 40A 50A 1 8 1 4 3 8 3 8 1 2 3 4 220 VAC 50/60 Hz 24 VDC 12 VDC 240 VAC 50/60 Hz 4 Note 2) Valve size 1 to 4 10 5 6 Note 2) Note) B: Slotted locking type B (tool required) 7 Note 2) 2 15 Note 1) CE-compliant: For D or DZ only Note 2) Semi-standard Note 3) For other rated voltages, please consult with SMC. 3 20 25
(mm) Symbol 1 2 3 Note 1) 4 Symbol Nil: Non-locking push type N.C. 1 MPa N.C. 0.5 MPa N.O. 1 MPa C.O. 1 MPa Note) 4 Note 2) A: Non-locking push type A (projecting) 1 6A 8A 10A 1 8 1 4 3 8 5 6 Note 2) 7 Valve size 1 to 4 7 Note 2) 11 15 11 10A 3 8 B: Slotted locking type B (tool required) Note) Note 1) Electrical entry: D or DZ only Note 2) Semi-standard Note 3) For other rated voltages, please
N.C. 6A 8A 10A 10A 15A 20A 25A 32A 32F 40A 40F 50A 50F 1 8 1 4 3 8 3 8 1 2 3 4 7 1 15 2 20 3 25 4 1 1 1 4 32 5 11 4 B Flange 11 2 40 6 11 2 B Flange 2 50 7 2B Flange 634
4 2830 Rc1 3638 Rc1 1/4 4042 Rc1 1/2 4850 ( ( ( ( 5, 6, 7 5, 6, 7 5, 6, 7 5, 6, 7 ) ) ) ) , G1/2 Rc2 4850 , , , , M3 0.5 ~0.6 Nm + G 1/2 M3 0.5 ~0.6 Nm M3 0.5 ~0.6 Nm A-A () 1) 2) 3) 30 1) 2) 1 0.1MPa 5 VN-OMP0002 Series Series Series Series 1 DC AC VT307 VNA ( ) (JIS B2301)(JIS B 2302) VNA (JIS B 6349) VNA 1 ISO VG32 VNA ( JIS K 6439) VNA VNA VNA VNA AS AS AS AS VNA AS 10A
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Port size (IN, OUT port) Single Port size Rc size VR VPA3145 VPA3165 VPA3185 Symbol Body size 03 (10A) 3 8 (15A) 1 2 (20A) 3 4 (25A) 1 1 4 6 1 2 VH 04 06 10 12 14 20 8 1 2 1 Valve option VHS Nil For general purpose (32A) 1 4 1 (40A) 1 2 1 Body ported
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Port size (IN, OUT port) Single Port size Rc size VR VPA3145 VPA3165 VPA3185 Symbol Body size 03 (10A) 3 8 (15A) 1 2 (20A) 3 4 (25A) 1 1 4 6 1 2 VH 04 06 10 12 14 20 8 1 2 1 Valve option VHS Nil For general purpose (32A) 1 4 1 (40A) 1 2 1 Body ported
vacuum/low pressure T VQ Port size (IN, OUT port) Conduit terminal with indicator light TS Conduit terminal with surge voltage suppressor TZ Conduit terminal with light/surge voltage suppressor DL DIN terminal with indicator light DS DIN terminal with surge voltage suppressor DZ DIN terminal with light/surge voltage suppressor VKF Port size Rc (Nominal size) VP3145 VP3165 VP3185 Symbol 03 (10A
Without sub-plate VH VPA454/474 00 03 (10A) 3 8 (15A) 1 2 (20A) 3 4 (25A) 1 (32A) 1 4 1 (40A) 1 2 1 VHS standard 5 Body size 04 06 10 12 14 VPA450 Piping 3 4 standard 7 11 4 JIS Symbol 2 position double VPA4250/4270 0 Side ported 1 Bottom ported 2 position single VPA4150/4170 VPA470 4 W/o sub-plate Option Specifications Fluid Air 3 position exhaust center VPA4450 3 position closed center
) 3 8 (15A) 1 2 03 04 5 24 VDC VP450 6 12 VDC 06 (20A) 3 4 10 (25A) 1 7 240 VAC, 50/60 Hz 9 Other 12 (32A) 1 4 1 14 (40A) 1 2 1 VP470 Option Note) There is no 3 position type for Series VP470.
J Stainless steel F 24 VDC 6 25A N.C. K C37 Stainless steel 1 25 G DIN terminal 24 VDC D N.O.