Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 45, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Clean Room, Operating Temperature(°C): -10~70, Cushion: Rubber cushion, Operating Pressure(MPa): 0.08 to 0.7, Specification: Built-in magnet, Auto Switches: Without
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 45, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Clean Room, Operating Temperature(°C): -10~70, Cushion: Rubber cushion, Operating Pressure(MPa): 0.08 to 0.7, Specification: Built-in magnet, Auto Switches: Without
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 60, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Clean Room, Operating Temperature(°C): -10~70, Cushion: Rubber cushion, Operating Pressure(MPa): 0.08 to 0.7, Specification: Built-in magnet, Auto Switches: Without
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Clean Room, Operating Temperature(°C): -10~70, Cushion: Rubber cushion, Operating Pressure(MPa): 0.08 to 0.7, Specification: Built-in magnet, Auto Switches: Without
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Clean Room, Operating Temperature(°C): -10~70, Cushion: Rubber cushion, Operating Pressure(MPa): 0.08 to 0.7, Specification: Built-in magnet, Auto Switches:
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Clean Room, Operating Temperature(°C): -10~70, Cushion: Rubber cushion, Operating Pressure(MPa): 0.08 to 0.7, Specification: Built-in magnet, Auto Switches:
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Clean Room, Operating Temperature(°C): -10~70, Cushion: Rubber cushion, Operating Pressure(MPa): 0.08 to 0.7, Specification: Built-in magnet, Auto Switches: Without
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 175, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Clean Room, Operating Temperature(°C): -10~70, Cushion: Rubber cushion, Operating Pressure(MPa): 0.08 to 0.7, Specification: Built-in magnet, Auto Switches: Without
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 175, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Clean Room, Operating Temperature(°C): -10~70, Cushion: Rubber cushion, Operating Pressure(MPa): 0.08 to 0.7, Specification: Built-in magnet, Auto Switches: Without
Clean Series: Relief Type, Magnet: Built-in, Mounting: Front Flange, Stroke: 125mm, Cushion: Rubber Bumper (Standard), Head Cover Port: Axial, Auto Switch: C73--Reed, DC Volt >5 <24, AC Volt <100, LED, Lead Wire, Lead Wire or Prewired Connector: -, Number: -, Bore Size: 10mm
Magnet: D (Built-in Magnet), Mounting: B (Basic Style), Bore Size: 10mm, Seal Material: V (FKM), Stroke: 125mm, Head Cover Port: R (Axial Direction), Auto Switch: B (w/o Switch, w/ Magnet)
Magnet: D (Built-in Magnet), Mounting: B (Basic Style), Bore Size: 16mm, Seal Material: R (NBR), Stroke: 125mm, Head Cover Port: R (Axial Direction), Auto Switch: B (w/o Switch, w/ Magnet)
Magnet: D (Built-in Magnet), Mounting: B (Basic Style), Bore Size: 16mm, Seal Material: V (FKM), Stroke: 125mm, Head Cover Port: R (Axial Direction), Auto Switch: B (w/o Switch, w/ Magnet)
Magnet: D (Built-in Magnet), Mounting: F (Front Flange), Bore Size: 10mm, Seal Material: V (FKM), Stroke: 125mm, Head Cover Port: R (Axial Direction), Auto Switch: B (w/o Switch, w/ Magnet)
Magnet: D (Built-in Magnet), Mounting: F (Front Flange), Bore Size: 16mm, Seal Material: V (FKM), Stroke: 125mm, Head Cover Port: R (Axial Direction), Auto Switch: B (w/o Switch, w/ Magnet)
Magnet: D (Built-in Magnet), Mounting: L (Axial Foot), Bore Size: 10mm, Seal Material: R (NBR), Stroke: 125mm, Head Cover Port: R (Axial Direction), Auto Switch: B (w/o Switch, w/ Magnet)
Magnet: D (Built-in Magnet), Mounting: L (Axial Foot), Bore Size: 10mm, Seal Material: V (FKM), Stroke: 125mm, Head Cover Port: R (Axial Direction), Auto Switch: B (w/o Switch, w/ Magnet)
Magnet: D (Built-in Magnet), Mounting: L (Axial Foot), Bore Size: 16mm, Seal Material: R (NBR), Stroke: 125mm, Head Cover Port: R (Axial Direction), Auto Switch: B (w/o Switch, w/ Magnet)
Magnet: D (Built-in Magnet), Mounting: L (Axial Foot), Bore Size: 16mm, Seal Material: V (FKM), Stroke: 125mm, Head Cover Port: R (Axial Direction), Auto Switch: B (w/o Switch, w/ Magnet)
Magnet: D (Built-in Magnet), Mounting: B (Basic Style), Bore Size: 10mm, Seal Material: R (NBR), Stroke: 125mm, Head Cover Port: R (Axial Direction), Auto Switch: B (w/o Switch, w/ Magnet)