SMC Corporation of America
Elite Part Number Search
Search Results "VXA2240-02F-1-B"

The base color of the new AC-B is uban white, maintaining a clean, modern look. Easy maintenance ; Attaches with SMC's standard interface ; Makes piping possible in 4 directions ; Port Size: M5 x 0.8, 1/8", 1/4", 3/8". 1/2"

BRACKETS SIZES PNAM-1 PNAM-2 PNAM-3 PNAM-4 130 A 130 80 80 30 B 30 30 30 55 C 75 45 55 YOKE MOUNT FOR GLOBE VALVES Please contact your SMC sales representative for availability.

pc., Input/output signal connector 1 pc., Power supply connector 1 pc., Operation manual (for installation/operation) 1, Quick manual (with a clear case) 1, Alarm code list sticker 1, Ferritic core (for communication) 1 pc.

Add an asterisk () at the beginning of electro-pneumatic regulator part numbers to be mounted. 6 (Light gray) 1/4" (Orange) Nil U D side 1 2 3 Note) A DIN rail with the length specified by the number of stations is attached to the manifold. For dimensions of the DIN rail, refer to the external dimensions. 1 3 3 DIN rail 1 ITV0030-3MS ITV0030-3ML 806 B

SJ3260-5MZ-C6 (1 set) SJ3260-5CZJ-C6 (1 set) Double solenoid, with switch (24 VDC) SUP/EXH block mounting position Specify the required specifications (including port sizes other than 8) by means of the manifold specification sheet.

X500 AC (50/60 Hz) 1 2 3 4 7 B DC 5 6 24 VDC 12 VDC X600 TRIAC output specification (Refer to page 14.) 100 VAC 200 VAC 110 VAC [115 VAC] 220 VAC [230 VAC] 240 VAC 24 VAC PE port EA/EB port VF1000 VF3000 > VF5000 > A, B port size VF5000 > > VF1000 > > VF3000 > > Port size M5 x 0.8 1/8 1/4 3/8 Symbol M5 01 02 03 Refer to Made to Order (Page 14) when piping to PE port is required.

Valves for both are easily replaced without changing existing piping.Compatible with a wide variety of fluids, Maximum operating pressure (MPa): 0.3~1.0, Effective area mm 2 (Cv): 1.4~9 (0.08~0.5), Orifice size (mm): 1.5, 2.2, 3, 4, Maximum system pressure: 1.0, VX3 BODY PT 1/4NPT, VALVE, VX3 3-WAY MEDIA VALVE, EA, VX3 BODY PT 1/4NPT, 8.62351 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

Cost effective and clean looking, series AR regulators offer various pressure range settings to accommodate most applications. The locking adjustment knob prevents accidental setting changes. The modular design of the AR series connects with other SMC air preparation equipment.Modular type regulator, Optional embedded pressure gauge , Available with built-in backflow mechanism , Knob is

Cost effective and clean looking, series AR regulators offer various pressure range settings to accommodate most applications. The locking adjustment knob prevents accidental setting changes. The modular design of the AR series connects with other SMC air preparation equipment.Modular type regulator, Optional embedded pressure gauge , Available with built-in backflow mechanism , Knob is

This combination Filter/ Regulator minimizes space and piping by integrating the 2 units into one. Standard features include a relieving regulator, which can be quickly locked by pushing down on the adjustment knob. There are many options, which include gauges, auto-drain, metal bowl and covers, different set pressures, etc. The AW is part of the family of modular air preparation units

This combination Filter/ Regulator minimizes space and piping by integrating the 2 units into one. Standard features include a relieving regulator, which can be quickly locked by pushing down on the adjustment knob. There are many options, which include gauges, auto-drain, metal bowl and covers, different set pressures, etc. The AW is part of the family of modular air preparation units

This combination Filter/ Regulator minimizes space and piping by integrating the 2 units into one. Standard features include a relieving regulator, which can be quickly locked by pushing down on the adjustment knob. There are many options, which include gauges, auto-drain, metal bowl and covers, different set pressures, etc. The AW is part of the family of modular air preparation units

This combination Filter/ Regulator minimizes space and piping by integrating the 2 units into one. Standard features include a relieving regulator, which can be quickly locked by pushing down on the adjustment knob. There are many options, which include gauges, auto-drain, metal bowl and covers, different set pressures, etc. The AW is part of the family of modular air preparation units

This combination Filter/ Regulator minimizes space and piping by integrating the 2 units into one. Standard features include a relieving regulator, which can be quickly locked by pushing down on the adjustment knob. There are many options, which include gauges, auto-drain, metal bowl and covers, different set pressures, etc. The AW is part of the family of modular air preparation units

Electric Slide Table/Compact Type Step Motor (Servo/24 VDC) Servo Motor (24 VDC) LES8, 16, 25 Series LES RoHS How to Order S 1 1 R J 6N LES 8 30 q w e r t y u i o !0 !1 !2 !

4 Compact Manometer Series PPA PPA100/101/102 How to Order Unit specifications PPA10 0 M Pressure specifications Nil M Option/Case holder With the unit switching function(1) 0.1 to 1 MPa (For high pressure) 101 to 10 kPa (For vacuum) 10 to 100 kPa (For low pressure) 0 1 2 Fixed in SI unit (2) None With PPA-B Nil B Note 1) With unit switching function is not permitted to sell for the domestic

Nil FKM 1349-80*1 N1 EPDM 2101-80*1 P1 Barrel Perfluoro 70W Q1 Kalrez 4079 R1 Chemraz SS592 R2 SS630 R3 SSE38 S1 VMQ 1232-70*1 T1 FKM for Plasma 3310-75*1 *1 Values at normal temperature, excluding gas permeation *2 Refer to Construction on page 5 for changed part. Number corresponds with the parts number on the construction drawing.

600 ---2 ---2 200 400 ---1 ---1 100 200 Air consumption Air consumption 0 0 0 0 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.0 0.1 0.2 0.3 0.4 0.5 0.6 Supply pressure [MPa] Supply pressure [MPa] ZH30-X185 ZH40-X185 3,500 5,000 ---7 ---7 Suction flow rate [L/min (ANR)] Note 1) Air consumption [L/min (ANR)] Discharge flow rate [L/min (ANR)] Suction flow rate [L/min (ANR)] Note 1) Air consumption [L/min (