Center of F.R.L. body A D Silencer Compact resin type High noise reduction type B B A A Dimensions [mm] Model Port size R Dimensions [mm] A B AN302-03 3/8 84 28 AN402-04 1/2 95 34 Model Port size R A B AN30-03 3/8 58.5 20 AN40-04 1/2 68 24 3 Modular Connection Type Residual Pressure Relief 3 Port Solenoid Valve VP500/700 Series Dimensions VP517 Surge voltage suppressor (for D YS, D YZ) Manual
17.98 15.86 7.08 7.52 8.78 NCX2_15-700 2.89 3.00 16.25 4-0.31 Counter Bore Depth 0.17 4-0.17 Through Hole 1.125+0.0004 Adjustment Bolt 19.98 17.86 8.08 8.52 9.78 NCX2_15-800 3.39 3.00 18.25 D I M E N S I O N S B A S I C T Y P E (N)25 S E R I E S NCX2 4-0.37 Counter Bore Depth 0.21 2-NPT1/8 Plugged +0.0004 4-0.22 Through Hole 0.55 2.63 2.63 3.11 1.38 2.63 Depth 0.32 Applicable Pin 1/4 4-1/4-28
VBA2: Tightening torque: 22 to 24 Nm (R3/8) VBA4: Tightening torque: 28 to 30 Nm (R1/2) (3) Change of the booster regulator OUT port plug VBA2, 4: Tightening torque: 24 Nm (M10) booster regulator by applying the seal tape. with a monkey spanner. Booster regulator Air tank Groove O-ring (4) O-ring
VBA2: Tightening torque: 22 to 24 Nm (R3/8) VBA4: Tightening torque: 28 to 30 Nm (R1/2) (3) Change of the booster regulator OUT port plug VBA2, 4: Tightening torque: 24 Nm (M10) booster regulator by applying the seal tape. with a monkey spanner. Booster regulator Air tank Groove O-ring (4) O-ring
Solenoid on side A 0 2 4 6 8 16 28 30 Side D After maintenance is complete, perform appropriate functional inspections. Stop operation if the equipment does not function properly. Safety cannot be assured in the case of unexpected malfunction.
ITV VBA VE AMR3100 AMR4100 AMR5100 AMR6100 SAMR, #1 SAMR, #2 SAMR, #3 SAMR, #4 VY G N Bracket mounting dimension With auto drain Model Port size A M L K J H G F E D C B U (Body) V (Adapter) L 178 211 277 321 B 260 298 366 432 T 9 9 11 11 S 8 7 10 15 R 78 97 98 115 P 50 35 45 46.5 AL 1 4, 3 8 1 4, 3 8 144 166 188 230 182 215 281 325 21.5 18 16 18.5 37 37 42 42 3.2 3.2 4.5 4.5 32 40 48 56 28
CD CT CU CD hole H10 Shaft d9 A B CL A B CL 102.5 65.5 92.5 95 58 85 10 5 14 32 114 75 104 103.5 64.5 93.5 10 6 14 40 121.5 75.5 111.5 111.5 65.5 101.5 14 7 20 50 RR CW CU CX + 0.4 + 0.2 129 77 115 123 71 109 14 8 20 63 L B + Stroke CL + Stroke A + Stroke CZ 0.1 0.3 Bore size (mm) CW CX N RR CZ L L1 Rod end male threads 32 20 18 36 7 28.5 M6 x 1.0 10 40 22 18 36 7 28.5 M6 x 1.0 10 50 28
Dimensions Model Metric size D2 D1 H1 H2 H3 H4 H5 L1 L2 L3 Inch size TMH-05 21 8.3 8.5 15.4 7.7 9.3 6.4 6.3 3.3 11.7 TMH-06 13.1 TMH-07 26.5 10.6 11 20 10 11 7.2 7.1 4.3 13.5 10 TMH-08 TMH-09 15.5 TMH-10 18.5 34 14.6 14.2 28 14 14 9.6 9.5 4.3 TMH-11 18.8 5
Refer to page 28 for details.
OLP CM C01 CM MC2 ILS ILS FM2 MC1 THS EDV For Option V THP C12 EDV MC1 C11 MC2 FM1 MC2 C11 PRS FM1 P (G) EDV PE For Option V FM2 MC2 PRS MC1 P IDU55E,IDU75E-23 C12 GFCI L N PE SYMBOL DESCRIPTION CM Refrigerating Compressor FM1 Fan Motor For Condenser FM2 Fan Motor For Aftercooler MC Magnetic Contactor MC1 Magnetic Contactor MC2 Magnetic Contactor C01 Capacitor For CM C11 Capacitor For FM1
28 Series REAS Model Selection 3 Caution on Design 1 Example of Allowable Load Weight Calculation Based on Cylinder Mounting Orientation 4.
Function Setting [Function selection mode] 28 Default settings 28 F0 Reference condition Unit selection function 29 F1 Setting of OUT1 31 F2 Setting of OUT2 39 F3 Response time 44 F10 Display mode 45 F13 Reversed display mode 46 F20 External input 47 F22 Setting of analogue output 48 F30 Accumulated value hold 49 F31 Orientation correction function 50 F80 Display OFF mode 51 F81 Security
(Refer to specifications.) 28 Series CY3R Auto Switch Precautions 1 Be sure to read before handling. Design and Selection Warning 1. Confirm the specifications. In the same way, when operating below a specified voltage, although an auto switch may operate normally, the load may not operate.
Applicable shaft types: J, X, Z d1 = d1 = d1 = d1 = L2 = Y = C2 J axis X axis D2 = C2 = C K axis T axis (mm) (mm) (mm) d1 Size 30 50 63 80 100 d1 Size 30 50 63 80 100 Y 3 to 25 1 to 36 1 to 41 1 to 50 1 to 60 L2 max Y 2 Y Y Y Y D2 5 to 7.9 5 to 14.9 5 to 16.9 8 to 19.9 8 to 24.9 Size 30 50 63 80 100 2.5 4 to 7.5 4 to 8 6.8 to 11 6.8 to 13 2.5 4 to 7.5 4 to 8 6.8 to 11 6.8 to 13 11-7
Applicable shaft types: J, X, Z d1 = d1 = d1 = d1 = L2 = Y = C2 J axis X axis D2 = C2 = C K axis T axis (mm) (mm) (mm) d1 Size 30 50 63 80 100 d1 Size 30 50 63 80 100 L2 max Y 2 Y Y Y Y Y 3 to 25 1 to 36 1 to 41 1 to 50 1 to 60 D2 5 to 7.9 5 to 14.9 5 to 16.9 8 to 19.9 8 to 24.9 Size 30 50 63 80 100 2.5 4 to 7.5 4 to 8 6.8 to 11 6.8 to 13 2.5 4 to 7.5 4 to 8 6.8 to 11 6.8 to 13 11-7
Description Material Note 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 No.
(If m otor option is with lock, lo ck ca ble is also include d.) 200 to 230 LECSC2-S C2 S1 LECSS1S 100 to 120 *6 The standa rd direction of each c a ble is shaft side(A)..
Cotter pin size CJ1 Flat washer 16 M14 x 1.5 13 55.5 3 x 18l Polished round 12 22 25 24 12 55 38 40 Y-04D +0.3 +0.1 CJP CJ2 16 M18 x 1.5 15 55.5 3 x 18l Polished round 12 27 27 28 12 60 38 50, 63 Y-05D +0.3 +0.1 CM2 28 M22 x 1.5 19 76.5 4 x 25l Polished round 18 37 28 36 18 71 55 80 Y-08D +0.3 +0.1 CG1 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-
56 64 M2 26 85 96 M3 28 56 64 Model CY1H10 CY1H15 CY1H20 Model CY1H25 CY1HT25 CY1HT32 30 28 26 20 20 CY1H20 CY1H15 16 13 Moment Nm Moment Nm CY1S 10 10 2 2.5 3 4 5 3 4 5 CY1H10 CY1L M3 2 CY1H10 1.5 1 1 CY1H 0.5 0.5 70 100 300 500 1000 70 100 300 500 1000 M1 M2 Piston speed mm/s Piston speed mm/s CY1F Graph (3) Graph (2) CYP Moment generated by the workpiece weight even when the cylinder
The facility water outlet temperature can be up to 60 deg.C Pipe diameter Table 3-3 Pipe Diameter Pipe Diameter Recommended torque (Material: SS* vs SS) Facility water inlet Rc1/2 28 to 30Nm (20.7 to 22.1ft-lbf) Facility water outlet Rc1/2 28 to 30Nm (20.7 to 22.1ft-lbf) Circulating fluid supply Rc3/4 28 to 30Nm (20.7 to 22.1ft-lbf) Circulating fluid return Rc3/4 28 to 30Nm (20.7 to 22.1ft-lbf