SMC Corporation of America
Elite Part Number Search
Search Results "PF3A702H-L"

Model: 10 (200 L/min [ANR]), Pressure Range: 3 (0.005~0.5MPa), Power Voltage: 0 (24VDC), Input Signal: CC (CC-Link), Monitor Output: For Input Signal/Communication Model Types 40, CC, DE, PR, RC and IL Only, Thread: Rc(PT), Port Size: 1 [1/8 (1000)], Accessory: C (L Bracket), Cable Connector: L (Right Angle Style 3m)

Model: 30 (4000 L/min), Pressure Range: 3 (0.005~0.5MPa), Power Voltage: 0 (24VDC), Input Signal: PR (PROFIBUS DP®), Monitor Output: For Input Signal/Communication Model Types 40, CC, DE, PR, RC and IL Only, Thread: N (NPT), Port Size: 4 [1/2 (3000)], Accessory: C (L Bracket), Cable Connector: L (Right Angle Style 3m)

Model: 20 (1500 L/min), Pressure Range: 5 (0.005~0.9MPa), Power Voltage: 0 (24VDC), Input Signal: 0 (Current Style 4~20mADC), Monitor Output: 4 (Analog Output 4~20mA Sink Requires a Sourcing Type Analog Input Module), Thread: Rc(PT), Port Size: 2 [1/4 (1000,2000,3000)], Accessory: C (L Bracket), Cable Connector: L (Right Angle Style 3m)

Model: 20 (1500 L/min), Pressure Range: 3 (0.005~0.5MPa), Power Voltage: 0 (24VDC), Input Signal: 0 (Current Style 4~20mADC), Monitor Output: 4 (Analog Output 4~20mA Sink Requires a Sourcing Type Analog Input Module), Thread: Rc(PT), Port Size: 2 [1/4 (1000,2000,3000)], Accessory: C (L Bracket), Cable Connector: L (Right Angle Style 3m)

Model: 10 (200 L/min [ANR]), Pressure Range: 1 (0.005~0.1MPa), Power Voltage: 0 (24VDC), Input Signal: 40 (Preset Input), Monitor Output: For Input Signal/Communication Model Types 40, CC, DE, PR, RC and IL Only, Thread: Rc(PT), Port Size: 1 [1/8 (1000)], Accessory: C (L Bracket), Cable Connector: L (Right Angle Style 3m)

Model: 20 (1500 L/min), Pressure Range: 5 (0.005~0.9MPa), Power Voltage: 0 (24VDC), Input Signal: 52 (16 Points Preset Input - NPN Output), Monitor Output: For Input Signal/Communication Model Types 40, CC, DE, PR, RC and IL Only, Thread: N (NPT), Port Size: 2 [1/4 (1000,2000,3000)], Accessory: C (L Bracket), Cable Connector: L (Right Angle Style 3m)

Rated Flow Range: 10 to 100 L/min, Port Size, Pipe O.D.: Port Size: 25A, Pipe O.D.: 32mm, Output Specification: OUT1: NPN; OUT2: Analog 1 to 5V, Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: Bracket, Calibration Certificate: Calibration Certificate, Made to Order: -

Rated Flow Range: 10 to 100 L/min, Port Size, Pipe O.D.: Port Size: 25A, Pipe O.D.: 32mm, Output Specification: OUT1: PNP; OUT2: Analog 4 to 20mA, Lead Wire: w/o Lead Wire w/M8 Connector, Unit Specification: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: Bracket, Calibration Certificate: Calibration Certificate, Made to Order: -

Rated Flow Range: 2 to 16 L/min, Flow Adjustment Valve: None, Thread: G, Port Size: 1/2, Output Specification: OUT1: Analog 1 to 5V, Temperature Sensor: None, Lead Wire: w/o Lead Wire w/M8 Connector, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: Bracket, Calibration Certificate: -, Made to Order: -

Rated Flow Range: 2 to 16 L/min, Flow Adjustment Valve: None, Thread: NPT, Port Size: 1/2, Output Specification: OUT1: Analog 4 to 20mA, Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: Bracket, Calibration Certificate: Calibration Certificate, Made to Order: -

Rated Flow Range: 2 to 16 L/min, Flow Adjustment Valve: Flow Adjustment Valve, Thread: Rc, Port Size: 3/8, Output Specification: OUT1: Analog 1 to 5V, Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: Bracket, Calibration Certificate: -, Made to Order: -

Rated Flow Range: 2 to 16 L/min, Flow Adjustment Valve: None, Thread: NPT, Port Size: 1/2, Output Specification: OUT1: Analog 1 to 5V, Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: None, Calibration Certificate: Calibration Certificate, Made to Order: -

Rated Flow Range: 2 to 16 L/min, Flow Adjustment Valve: None, Thread: NPT, Port Size: 1/2, Output Specification: OUT1: Analog 4 to 20mA, Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: None, Calibration Certificate: Calibration Certificate, Made to Order: -

Rated Flow Range: 10 to 100 L/min, Flow Adjustment Valve: None, Thread: NPT, Port Size: 3/4, Output Specification: OUT1: Analog 4 to 20mA, Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: None, Calibration Certificate: Calibration Certificate, Made to Order: -

Rated Flow Range: 2 to 16 L/min, Flow Adjustment Valve: Flow Adjustment Valve, Thread: NPT, Port Size: 1/2, Output Specification: OUT1: Analog 1 to 5V, Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: Bracket, Calibration Certificate: -, Made to Order: -

Rated Flow Range: 5 to 40 L/min, Flow Adjustment Valve: None, Thread: NPT, Port Size: 1/2, Output Specification: OUT1: Analog 4 to 20mA, Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: Bracket, Calibration Certificate: Calibration Certificate, Made to Order: -

Rated Flow Range: 2 to 16 L/min, Flow Adjustment Valve: None, Thread: NPT, Port Size: 3/8, Output Specification: OUT1: Analog 4 to 20mA, Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: Bracket, Calibration Certificate: -, Made to Order: -

Rated Flow Range: 5 to 40 L/min, Flow Adjustment Valve: None, Thread: NPT, Port Size: 3/4, Output Specification: OUT1: Analog 1 to 5V, Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: None, Calibration Certificate: Calibration Certificate, Made to Order: -

Rated Flow Range: 5 to 40 L/min, Flow Adjustment Valve: None, Thread: NPT, Port Size: 1/2, Output Specification: OUT1: Analog 4 to 20mA, Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: Bracket, Calibration Certificate: -, Made to Order: -

Rated Flow Range: 2 to 16 L/min, Flow Adjustment Valve: None, Thread: NPT, Port Size: 3/8, Output Specification: OUT1: Analog 1 to 5V, Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: Bracket, Calibration Certificate: Calibration Certificate, Made to Order: -