SMC Corporation of America
Elite Part Number Search
Search Results "HRS400-AN-46-ADK"

Install an air filter. Install an air filter upstream near the valve. Select an air filter with a filtration size of 5m or smaller. Therefore, take appropriate measures to ensure air quality, by providing an after cooler, or water separator, if needed. Compressed air that contains excessive foreign material may cause malfunction of valves and other pneumatic equipment.

If using the product in an interlocking circuit: Provide a double interlocking system, for example a mechanical system Check the product regularly for proper operation Otherwise malfunction can result, causing an accident.

Install an air filter. Install an air filter upstream near the valve. Select an air filter with a filtration size of 5m or smaller. 2. Install an aftercooler, air dryer or drain catch before the filter. Compressed air that contains excessive foreign material may cause malfunction of valves and other pneumatic equipment. 3. Discharge condensates regularly.

Do not apply an impact load or strong vibration while the lock is activated. If an external impact load or strong vibration is applied to the product, the lock will lose its holding force and damage to the sliding part of the lock or reduced lifetime can result.

When installing an ionizer with Auto balance sensor [body-mounting type] in proximity with an ionizer which operates in DC mode, they should be positioned at least 2m away from each other. When using an Auto balance sensor [body-mounting type] near an ionizer in DC mode, keep clearance of at least 2 m between them.

Install an air filter. Install an air filter upstream near the valve. Select an air filter with a filtration size of 5m or smaller. 2. Install an aftercooler, air dryer or drain catch before the filter. Compressed air that contains excessive foreign material may cause malfunction of valves and other pneumatic equipment. 3. Discharge condensates regularly.

Never use in an atmosphere of explosive gases. The structure of auto switches is not intended to prevent explosion. Never use in an atmosphere with an explosive gas since this may cause a serious explosion. 2. Do not use in an area where a magnetic field is generated. Auto switches will malfunction or magnets inside cylinders will become demagnetized.

If the operating fluid is ultra-dry air, consult SMC. 2.Install an air filter. Install an air filter upstream near the valve. Select an air filter with a filtration size of 5m or smaller. 3.Therefore, take appropriate measures to ensure good air quality, such as providing an after cooler, air dryer, or water separator.

Install an air filter. 2. Applied voltage: Install an air filter upstream near the valve. Select an air filter with a filtration size of 5 or smaller. When electric power is connected to a solenoid valve, be careful to apply the proper voltage. Improper voltage may cause malfunction or coil damage. 3.

Pay attention to the length of time that a switch is ON at an intermediate stroke position. When an auto switch is placed at an intermediate position of the stroke and a load is driven at the time the piston passes, the auto switch will operate, but the operating time will be short if the speed is too fast. As a result, the load may not operate completely.

Install an air filter. Install an air filter upstream near the valve. Select an air filter with a filtration size of 5 m or smaller. 3. Take measures to ensure air quality, such as by installing an aftercooler, air dryer, or water separator. Compressed air that contains a large amount of drainage can cause malfunction of pneumatic equipment such as valves.

If using the product in an interlocking circuit: Provide a double interlocking system, for example a mechanical system Check the product regularly for proper operation Otherwise malfunction can result, causing an accident.

This system should not be applied with an undue force such as caused by piping installation.

An EXH block base ass'y is used in the blocking position when ordering an EXH spacer incorporated with a manifold No. However, do not order an EXH block base ass'y because it is attached to the spacer. When separately ordering an individual EXH spacer, separately order an EXH block base ass'y because it is not attached to the spacer.

An application which could have negative effects on people, property, or animals requiring special safety An application which could have negative effects on people, property, or animals requiring special safety analysis. analysis. 4.Use in an interlock circuit, which re Use in an interlock circuit, which re Use in an interlock circuit, which re Use in an interlock circuit, which requires

Connector with cable or without cable may be selected when placing an order for the power supply cable. When only an e-con is required, place an order for it as a part.

Install an air filter upstream near the valve. Select an air filter with a filtration size of 5 m or smaller. 3. Take measures to ensure air quality, such as by installing an aftercooler, air dryer, or water separator. Compressed air that contains a large amount of drainage can cause the malfunction of pneumatic equipment, such as valves.

Description SY3000 SY5000 Note Manifold block assembly Manifold block assembly part number differs according to an attached lead wire assembly based on the connector spec. Select an appropriate port number from the table of manifold block assembly part number shown below.(Gasket 7 is supplied as an accessory.)

Cautions for use in an interlock circuit When an auto switch is used for an interlock signal requiring high reliability, devise a double interlock system to avoid trouble by providing a mechanical protection function, or by also using another switch (sensor) together with the auto switch. Also perform periodic maintenance inspections and confirm proper operation. 9.