ZS-10-5A-50 1 pc. 6 1A 36 VJ10 ZP 2 m (For 110 VAC) 2.5 m Lead wire length 6 Nil 3A 36 VJ10 SP 3 m 0.6 m 30 50 3 m 5 m ZCUK The asterisk () denotes the symbol for assembly. AMJ AMV Ejector System/Recommended Model (The models below will have shorter deliveries.)
M plug connector 2 position double: VZS3250-M(Z)-01 02 3 position closed center: VZS3350-M(Z)-01 02 3 position exhaust center: VZS3450-M(Z)-01 02 3 position pressure center: VZS3550-M(Z)-01 02 DIN terminal 2 position double: VZS3250-D(Z)-01 02 3 position closed center: VZS3350-D(Z)-01 02 3 position exhaust center: VZS3450-D(Z)-01 02 3 position pressure center: VZS3550-D(Z)-01 02 164 (3 position
if an operator does not follow the specified procedures during the operation or maintenance of the product or does not follow the instructions necessary to avoid it.
Caution (1) Install an air filter. Install an air filter at the upstream side of valve. Select a filtration rating of 5 m or below, or that equivalent to or lower than ISO 8573-1:2010 [6:4:4] * This rating is equivalent to the rating produced when an air filter is installed for the purity class [7:4:4] of the inlet side compressed air.
M plug connector 2 position double: VZS2250-M(Z)-01 3 position closed center: VZS2350-M(Z)-01 3 position exhaust center: VZS2450-M(Z)-01 3 position pressure center: VZS2550-M(Z)-01 DIN terminal 2 position double: VZS2250-D(Z)-01 3 position closed center: VZS2350-D(Z)-01 3 position exhaust center: VZS2450-D(Z)-01 3 position pressure center: VZS2550-D(Z)-01 Applicable cable O.D.: 3.5 to 7 MAX
Knuckle Pin (common with double clevis pin) Rod End Nut d d Dd9 C m l L t m t H B Material: Carbon steel mm Material: Rolled steel mm Part no. Applicable bore size (mm) 20 25 32, 40 50 Applicable bore size (mm) Snap ring l Part no.
Refer to the construction drawings regarding cylinder materials. 2) Install a cover over the rod if it is used in an area that is dusty, or in an environment in which water or oil splashes on the cylinder. 3) When using auto switches, do not operate in an environment with strong magnetic fields. 3-3.
An application which could have negative effects on people, property, or animals requiring special safety analysis. 4.Use in an interlock circuit, which requires the provision of double interlock for possible failure by using a mechanical protective function, and periodical checks to confirm proper operation. -2- 3A 4/5 Safety Instructions Caution 1.
The micromist separator (with a pressure gauge) is an Made to Order. For notes w and e, refer to the left. 4B/6B 870 M20 X l 500 AMD1000 w When the element has reached its replacement interval, replace it immediately with a new element.
Lubrication Manual override Shock/Vibration resistance (2) Enclosure Non-locking push type 150/50 m/s2 Dustproof Note 1) Based on dynamic performance test, JIS B 8374-1981.
Safety Instructions Be sure to read the Handling Precautions for SMC Products (M-E03-3) and Operation Manual before use.
This may also have an adverse effect on the peripheral equipment in proximity. Should a valve be continuously energized for long periods, or its daily energized state exceeds its non energized state, please use an energy saving type AC, energizing for long periods of time continuously, select the air-operated valve and use the continuous duty type of the VT307 for a pilot valve.
The adjustment of the throttle valve, the stability of the closed loop including the booster relay is improved. -3- MODEL IL100 BOOSTER RELAY -3IN THROTTLE VALVE DIAPHRAGM(A) EXH INPUT CHAMBER DIAPHRAGM(B) EXHAST HOLE OUT SUP INTERNAL VALVE THROTTLE VALVE SUP PRESSURE IN FORCE + DISPLACEMENT 1 PRESSURE OUT DIAPHRAGM(A) MAIN VALVE m N Pa (S) Pa Pa/M EQUIVALENT SPRING m/N FORCE DIAPHRAGM(
m]Yaw moment: My [N?m]Roll moment: Mr [N?m]LEHF20K2- 980.680.681.4
(A) 4 (B) 2 (A) 4 (B) 2 0.6 SS5YJA5 The remainder of the manifold part number is called out the same as an SS5YJ5 0.5 1 (P) 3 (R) 1 (P) 3 (R) Pilot pressure range 3 position pressure center 0.4 (A) 4 (B) 2 Specify the part numbers for the valve(s), blank plate assembly and manifold base. 0.3
Note 15) Standard lead wire length for pressure sensor is 3 m. Standard lead wire length with connector for switch for vacuum and the lead wire length for switch with energy saving function is 2 m. Note 16) Select C, L, L1, Y when the pressure sensor (P, T) is selected for t Pressure Sensor/Digital Pressure Switch for Vacuum Specifications.
m]Yaw moment: My [N?m]Roll moment: Mr [N?m]LEHF32K2- 1761.41.42.8
m]Yaw moment: My [N?m]Roll moment: Mr [N?m]LEHF40K2- 294224
m]Yaw moment: My [N?m]Roll moment: Mr [N?m]LEHF32K2- 1761.41.42.8
Safety Instructions Be sure to read Handling Precautions for SMC Products (M-E03-3) before using.