Flow Rate Range: 50 [1 to 50 (25 for CO2) ℓ/min], Flow Adjustment Valve: None, Port Size: ø6 One-touch Fitting, Piping Entry Direction: Bottom Side, Output Specification: D [1 NPN Outputs + Analog (4 to 20 mA)], Unit Specification: -, Instruction Manual: -, Calibration Certificate: -, Connector: -, Option: -
Flow Rate Range: 50 [1 to 50 (25 for CO2) ℓ/min], Flow Adjustment Valve: None, Port Size: ø6 One-touch Fitting, Piping Entry Direction: Bottom Side, Output Specification: D [1 NPN Outputs + Analog (4 to 20 mA)], Unit Specification: Unit Switching Function, Instruction Manual: With Instruction Manual, Calibration Certificate: None, Connector: w/o Lead Wire w/Connector, Option: -
Flow Rate Range: 50 [1 to 50 (25 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: ø6 One-touch Fitting, Piping Entry Direction: Bottom Side, Output Specification: D [1 NPN Outputs + Analog (4 to 20 mA)], Unit Specification: -, Instruction Manual: -, Calibration Certificate: -, Connector: -, Option: -
Flow Rate Range: 50 [1 to 50 (25 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: NPT1/8, Piping Entry Direction: Bottom Side, Output Specification: D [1 NPN Outputs + Analog (4 to 20 mA)], Unit Specification: Unit Switching Function, Instruction Manual: With Instruction Manual, Calibration Certificate: w/Calibration Certificate, Connector: W [Lead Wire w/Connector (2m) + Rubber Cover
Flow Rate Range: 50 [1 to 50 (25 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: NPT1/8, Piping Entry Direction: Bottom Side, Output Specification: D [1 NPN Outputs + Analog (4 to 20 mA)], Unit Specification: Unit Switching Function, Instruction Manual: With Instruction Manual, Calibration Certificate: w/Calibration Certificate, Connector: w/o Lead Wire w/Connector, Option: -
Flow Rate Range: 50 [1 to 50 (25 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: Rc1/8, Piping Entry Direction: Straight, Output Specification: D [1 NPN Outputs + Analog (4 to 20 mA)], Unit Specification: Fixed SI Unit, Instruction Manual: -, Calibration Certificate: -, Connector: -, Option: -
Flow Rate Range: 50 [1 to 50 (25 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: Rc1/8, Piping Entry Direction: Straight, Output Specification: D [1 NPN Outputs + Analog (4 to 20 mA)], Unit Specification: Fixed SI Unit, Instruction Manual: With Instruction Manual, Calibration Certificate: None, Connector: W [Lead Wire w/Connector (2m) + Rubber Cover], Option: Bracket for w/Flow Adjustment
Flow Rate Range: 50 [1 to 50 (25 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: Rc1/8, Piping Entry Direction: Straight, Output Specification: D [1 NPN Outputs + Analog (4 to 20 mA)], Unit Specification: Fixed SI Unit, Instruction Manual: With Instruction Manual, Calibration Certificate: None, Connector: w/o Lead Wire w/Connector, Option: -
Flow Rate Range: 50 [1 to 50 (25 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: NPT1/8, Piping Entry Direction: Bottom Side, Output Specification: D [1 NPN Outputs + Analog (4 to 20 mA)], Unit Specification: Fixed SI Unit, Instruction Manual: With Instruction Manual, Calibration Certificate: w/Calibration Certificate, Connector: W [Lead Wire w/Connector (2m) + Rubber Cover], Option
Flow Rate Range: 50 [1 to 50 (25 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: NPT1/8, Piping Entry Direction: Bottom Side, Output Specification: D [1 NPN Outputs + Analog (4 to 20 mA)], Unit Specification: Fixed SI Unit, Instruction Manual: With Instruction Manual, Calibration Certificate: w/Calibration Certificate, Connector: w/o Lead Wire w/Connector, Option: -
Flow Rate Range: 50 [1 to 50 (25 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: ø1/4 One-touch Fitting, Piping Entry Direction: Bottom Side, Output Specification: D [1 NPN Outputs + Analog (4 to 20 mA)], Unit Specification: Unit Switching Function, Instruction Manual: With Instruction Manual, Calibration Certificate: None, Connector: Lead Wire w/Connector (2 m), Option: Panel Mount
Flow Rate Range: 50 [1 to 50 (25 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: ø1/4 One-touch Fitting, Piping Entry Direction: Bottom Side, Output Specification: D [1 NPN Outputs + Analog (4 to 20 mA)], Unit Specification: Unit Switching Function, Instruction Manual: With Instruction Manual, Calibration Certificate: None, Connector: w/o Lead Wire w/Connector, Option: -
Nq Body size 20 25 30 40 50 60 Symbol Description Nw With backflow function Nil Without backflow function K*1 With backflow function + Ne Pipe thread type Nil Rc N NPT F G + 01 1/8 02 1/4 03 3/8 04 1/2 06 3/4 10 1 + Nr Port size a Mounting Nil Without mounting option B*3 With bracket H With set nut (for panel mount) + Nil Without pressure gauge E Square embedded type pressure gauge (with
Size: 50, Thread Type: Rc, Port Size: 06 (3/4), Mounting: B (w/Bracket), Float Type Auto Drain: D [N.O. (Normally Open)], Bowl: Sizes 20, 30, 40: Polycarbonate Bowl; Sizes 50, 60: Stainless Steel, Drain Port: w/Drain Cock, Indicator: w/o Indicator, Flow Direction: Left to Right, Drain Cock w/Barb Fitting: None, Pressure Unit: Name Plate and Caution Plate for Bowl in SI Units: MPa
Response time (ms) (0.5 MPa) Type of actuation 52-SY5000 26 or less 22 or less 38 or less 52-SY7000 38 or less 30 or less 56 or less 52-SY9000 50 or less 50 or less 70 or less 2-position single 2-position double 3-position Note 1) According to dynamic performance test JIS B8375-1981. Note 2) Response time when barriers were combined with a valve.
AU200/300 Effective thread depth 6.5 4-M5 x 0.8 AU200, 300 Float type auto-drain Port size H G F E D C B A Model Port size 1 4 / 3 8 AU200 / 50 70 61 30 40.5 31.5 164 165 AU300 50 70 61 30 40.5 31.5 188.5 165 14-3-12
Specifications Fluid Air Type of actuation N.C. only (N.O. only for vacuum) For ordinary pressure 0.2 to 0.8 MPa For vacuum and low pressure 101.2 kPa to 0.2 MPa Operating pressure range Pilot pressure range Ambient and fluid temperature (C) Refer to the graph of pilot pressure. 0 (No freezing) to 60 Lubrication Required (Turbine oil, Class 1 lSO VG32 equivalent) Mounting orientation Free 150/50
-X 20Data 6-2-1 2 Air Cylinder Double Acting, Single Rod Series CJ1 4 Specifications Double acting, Single rod Action Air Fluid 1.05 MPa Proof pressure 0.7 MPa Maximum operating pressure JIS Symbol Double acting, Single rod 0.2 MPa Minimum operating pressure 10 to 70C (No freezing) Ambient and fluid temperature Piston speed 50 to 500 mm/s Formation of small series of a double acting cylinder
Grease pack part no.: GR-S-010 (10 g), GR-S-020 (20 g) Piston seal NBR 47, 50 to 52, 55 and 56 are non-replaceable parts, so they are not included in the seal kit.
Cylinder Inner Diameter: D(φ): 50, Stroke: L(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Air Cushion, Port thread type: G, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number of