If a valve is placed immediately before the product, regardless of the operational state of the trigger, instantaneous air release may occur when compressed air is supplied. 13. If the supply pressure of compressed air is less than the product specification (0.05 MPa), the valve in the product may not operate correctly.
IZH IZH BEST DETECTING POSITION 50mm Sensor part 2 x 3.4 600 16.6 SMC 9 4.8 87.5 BEST DETECTING POSITION 50mm 13 8.8 0.5 6.5 7 (7.5) (175) 60 (12.3) BEST DETECTING POSITION 50mm 86 (55) (9.3) 21 519 IZH10 Series Names and Functions of Individual Parts LCD display Display of charged electricity Display of peak/bottom value Peak display P Bottom display b Measured Potential 20.0kV AUTO POWER-OFF
mounting) 5 Step Motor Controller JXCE1/91/P1/D1/L1 Series Dimensions JXCL1 35 4.5 For body mounting (Screw mounting) (11.5) 67 32.5 1.2 84.2 64.2 35 193.2 (When removing DIN rail) 187.3 (When locking DIN rail) 152.5 161 170 Mountable on DIN rail (35 mm) 77 17.5 4.5 For body mounting (Screw mounting) L 5.25 12.5 (Pitch) 7.5 5.5 (25) (35) 1.25 L Dimensions [mm] No. 1 2 3 4 5 6 7 8 9 10 11 12 13
Fluorine coated KKA3 KKA4, 6, 7, 8, 9 KQG2 Plated with fluorine-contained material Fluorine coated Fluorine coated Fluorine coated Fluorine coated KKA3, 4, 6 KKA7, 8, 9 Equivalent to Stainless steel 304 Stainless steel 304 6 Plug valve spring KG KFG2 Equivalent to Stainless steel 304 Stainless steel 304 Stainless steel 304 Stainless steel 304 Stainless steel 304 10 Collar spring MS 11 12 13
Refer to back page 50 for Safety Instructions and pages 13 to 17 for Fittings and Tubing Precautions. DM KDM Caution KB 1. Implement the tube piping in such a way that lateral load should not be applied on the ball bearings at the rotating part, otherwise it may adversely affect the life expectancy. A flexible polyurethane tube is recommended when lateral load is applied.
Refer to back page 50 for Safety Instructions and pages 13 to 17 for Fittings and Tubing Precautions. H/DL L/LL KC Caution How to Use Caution KK Please do not attach metal rods or metal pipes. Metal rods or pipes cannot be secured and the fittings will shoot out. Also, if tubes are attached after metal rods or pipes have been attached, the tubes will not hold and may come loose.
Auto Switch Proper Mounting Position (Detection at stroke end) and Its Mounting Height Auto switch (Sensor section) 16 to 25 Indicator light A 17.5 B [mm] Auto switch model Bore size D-M9 J A B U 16 9.5 7 21 20 9.5 8.5 23.5 25 9.5 9 27 32 11 8 29 40 15 10.5 31 50 13 13.5 36 63 15.5 16.5 41.5 22 U 64.5 4 Auto switch (Amplifier section) 32 to 63 A 17.5 B U Note) Adjust the auto switch after
Failure to do so may cause a malfunction. 13. Do not use the product in places where it will be exposed to radiant heat. Such places are likely to cause a malfunction. 7. When the Fieldbus system is installed in machinery/equipment, provide adequate protection against noise by using noise filters, etc. Noise in signal lines may cause a malfunction. 8.
and Cover: Stainless steel 304, O-ring: NBR/FKM Element Lock Material Stainless steel 304 Construction Cylindrical type Step type Cylindrical type Step type Cylindrical type 5 m, 20 m 5 m, 20 m 5 m, 20 m 5 m 5 m Nominal filtration rating Differential pressure proof 0.6 MPa 1.1 l (when reservoir is set separately) 1.8 l (when reservoir is set separately) 6 l Reservoir tank capacity Weight 13
Data Related Products Contact for upper/lower temperature limit deviation alarm (open when alarm occurs) Upper/lower temperature limit deviation alarm common Unused Contact for output cut-off alarm (open when alarm occurs) Common for output cut-off alarm Unused 1 2 Connection Connection Connection 3-4 M Connection cable M Power cable 5 6 DC cable Signal cable Connector side IEC 60320 C-13
Flow Characteristics (Initial conditions) Refer to page 5-10-13 for Precautions on these products. 2504 to 2511 1 Model 0.5 A B D Dimensions (mm) Recommended flow (m3/min (ANR)) 2.2 or less 3.0 or less 4.0 or less 8.0 or less 10.0 or less 1.5 or less 1.5 or less Model Port size R Effective area (mm2) Weight (g) 0.2 Inlet pressure (MPa) Noise level (dB (A)) 1 4 2504-002 33.9 111 62 30 24 106
AMV ZH -X185 Related Products Clearance for maintenance G A AFJ30, AFJ40 N T J D M U Bracket (Option) S R C V Q IN OUT 2 x P (Port size) B Clearance for maintenance G A E Model Standard specifications Optional specifications Bracket mount P A B C D E G J M N Q R S T U V AFJ20 1/8, 1/4 40 79.2 9.8 20 25 20 30 27 22 5.4 8.4 40 2.3 28 AFJ30 1/4, 3/8 53 104.1 14 26.7 30 35 26.7 41 35 23 6.5 13
-3 ALF-3-X208 12316 ALF-3 ALF-3-X208 12316 ALF-3 ALF-3-X208 12316 1 Auto feed 3 Sight dome 4 Polycarbonate 1 123122-3A (04) 123122-2A (03) 123122-1A (02) 123417A (12) 123416A (14) Bumper assembly 5 123122-3A 123210A 123310A 12356A 1 Needle stud assembly Retainer assembly Siphon tube assembly Sight dome seal Siphon nut seal Bumper retainer seal Bowl O-ring Housing O-ring 6 7 8 9 10 11 12 13
AP100 (13) Working principle When the MR units OUT side pressure is applied to piston q , piston q moves until it balances with the force of pressure adjustment spring w . The movement of piston q is detected by switch assembly e and outputs ON and OFF signals.
TEL: 317-899-4440 FAX: 317-899-3102 GERMANY SMC Pneumatik GmbH Boschring 13-15 D-63329 Egelsbach, Germany TEL: 06103-4020 FAX: 06103-402139 CANADA SMC Pneumatics (Canada) Ltd. 6768 Financial Drive Mississauga, Ontario, L5N 7J6 Canada TEL: 905-812-0400 FAX: 905-812-8686 ITALY SMC Italia S.p.A.
Note 2) When holding a workpiece close at the end of open/close stroke of fingers, detecting performance of the combinations listed in the above table may be limited, depending on the hysteresis of an auto switch, etc. 12-12-12 12-12-13
Metric size Inch size Body size Port size 3 1/8 standard 06 6 07 1/4 Symbol Cylinder side 4 1/4 standard 08 8 09 5/16 01 R1/8 5 3/8 standard 10 10 11 3/8 02 R1/4 6 1/2 standard 12 12 13 1/2 03 R3/8 04 R1/2 N01 NPT1/8 N02 NPT1/4 N03 NPT3/8 N04 NPT1/2 XTO Series Applicable tubing O.D.
Description Material Note 1 Body A PBT White 2 Body B Brass Electroless nickel plated 3 Needle Brass Electroless nickel plated 4 Seat ring Brass (1) 5 Lock nut Steel (2) 6 Handle Red painted Aluminum alloy 7 Push button Red POM 8 Cassette 9 U seal HNBR 10 Seal NBR 11 O-ring NBR 12 O-ring NBR 13 O-ring NBR 14 Valve core 15 Elbow body PBT 16 O-ring NBR AS21FE-01 only (3) 17 Accidental release
TB W Counterbore depth TC Inner cover holding screw Note) (mm) A 8 12 B 10.5 16 C 6.4 10.2 E 4 6 ED 9.5 13 EK 4 6 F 12.5 25 G 10 9 H 45 75 HA 23 39 HI 23 39 HL 37.6 63.3 HP 44 73.5 J M6 x 1 M10 x 1.5 JK 10 12 K 21 20 L 67 90 LD 5.6 9.2 Model CYV15 CYV32 +0.030 H9 0 +0.030 H9 0 LW 69 115 MM M4 x 0.7 M6 x 1 M 6 8 N 4.5 7.5 P 5/16-24 UNF 7/16-20 UNF PA 25 50 PB 60 100 PC 10 12 Q 112 147 QW 48
Metric size Inch size Type Elbow Universal 2 3 1 8" 5 32" 23 01 3.2 4 6 8 10 12 04 06 08 10 12 03 05 07 09 11 13 3 16" 1 4" 5 16" Control type Meter-out Meter-in 0 1 3 8" 1 2" Use 1/8" tube.