(0 to 60nC) (No condensation) 2 M7 or more (500 VDC measured via megohmmeter) between terminals and housing 1000 VAC (in 50/60 Hz) for 1 minute between terminals and housing 5 g (Excluding lead wire) R06: 6 reducer, R07: 1/4" reducer IP40 Grommet oil-resistant vinyl cabtire code 2 cores, 2.55, 3 m, Lead wire Note) Cross section: 0.18 mm2, Insulator O.D.: 0.96 mm High visibility A large LED
Note Bracket A ZS-46-A1 Tapping screw: Nominal size 3 x 8 L (2 pcs.) Bracket B ZS-46-A2 Tapping screw: Nominal size 3 x 8 L (2 pcs.)
Note Bracket A ZS-46-A1 Tapping screw: Nominal size 3 x 8 L (2 pcs.) Bracket B ZS-46-A2 Tapping screw: Nominal size 3 x 8 L (2 pcs.)
/OTHER), .44643 lb, ModelGas ratioRated flow rangeDisplayable rangeSettable rangeMax. analog output ArCO2Voltage (Vmax)Current (Imax)PFM71192%8%2 to 100 l/min2 to 105 l/min0 to 105 l/min5.00 V20.0 mA
of Parts 2.2 Name and Function of Parts 2.2.1 HRL-A-20 (Air cooled type) Fig. 2-2 Names of the parts (This drawing shows HRL200-A-20.) 2.2 Name and Function of Parts HRL Series 2-2 HRX-OM-W060 Chapter 2 Name and Function of Parts Table 2.2-1 Accessory list (1) Operation Manual 2 pcs.
Figure 5-67 CH1(2) Analog Output Setting Screen 1, 2 2. Use the ten-key to input a set value, and touch the [ENT] key. The CH1(2) Analog Output Setting screen 1, 2 is displayed, and the box appears flashing. Figure 5-68 Ten-key Screen [Tips] The setting has not taken effect while the box is flashing. A scaling must be specified to cause V Hi to be larger than V Lo (V Lo
1000 0 0 0 10 20 30 40 50 0 10 20 30 40 50 Circulating fluid temperature Circulating fluid temperature 60Hz 50Hz Fig. 9-4 Cooling capacity(HRS060--20-(BJM)) 1. 5 1. 5 1. 5 1. 5 1. 5 1. 5 kW kW kW kW kW kW 1 1 1 1 1 1 0. 5 0. 5 0. 5 0. 5 0. 5 0. 5 0 0 0 0 0 0 9.5 Heating capacity 0 2 0 2 0 2 0 1 2 0 1 2 0 1 2 HRS060-A-2050Hz HRS060-A-2050Hz HRS060-A-2050Hz HRS060-A-2060Hz HRS060-A-2060Hz
D across flats D across flats NCA D-X Stroke A Stroke B SN + Stroke (A + B) 4-NT Depth ND 20LD + Stroke (A + B) Data ZZ + Stroke (A + B) Bore size (in) MM KK A AA B C D DD E EA EE G K R WF Y LD P PC ZZ SN 150 (1.5") 5/8 7/16-20 3/4 2.02 1 1/8 3/8 9/16 1/4-28 2 0.3 3/8 1.26 9/32 1.43 1 1.71 7.44 2.36 1.30 9.44 5.56 200 (2") 5/8 7/16-20 3/4 2.60 1 1/8 3/8 9/16 5/16-24 2 1/2 0.3 3/8 1.26 11
JXC-OMU0029-A 2.4 Option (1) Actuator cable (5m or less) -signal Terminal no. Cable color Terminal no. A B-1 Brown 2 Cable length (L) A A-1 Red 1 B B-2 Orange 6 1 1.5m B A-2 Yellow 5 COM-A/COM B-3 Green 3 3 3m COM-B/ A-3 Blue 4 5 5m Shield Cable color Terminal no.
1/2 3/4 0 1 1/4 4 1/2 1/4 3/8-24 4 1/2 2 1 1/4 1/2 5/8 4.7 1 1/2 1 5/8 7 7/8 1-14 1 3/8 Oversized Rod-Rod Side Flange Style: NCA1F (XB5) P + Stroke Y C 2-EE (NPTF) 4-FB (Hole) AA D across flats KK B MM EA BA E R A W F G J 4-DD TF LF + Stroke WF ZB + Stroke UF Bore size (in) MM KK A AA B BA C D DD E EA EE F FB G J R TF UF W WF LF Y P ZB 200 (2") 1 3/4-16 1 1/8 2.6 1 1/2 1 1/8 1/2 7/8 5/16
Proper use of the seal cap enables the enclosure to achieve IP67 specification. -30No.EX-OMN0030-D Specification Specifications Model EX600-ED2EX600-ED3Power connector M12 (5 pin) Plug 7/8 inch (5 pin) Plug Power Power supply (Control and input) 24 VDC 10% Class2, 2 A 24 VDC 10%, 8 A Power supply (Output) 24 VDC +10/-5% Class2, 2 A 24 VDC +10/-5%, 8 A Enclosure IP67 (With manifold assembled
Do not connect the cable with the factory side at this point. 2. Turn OFF the main breaker of this system. 3. Undo the screws (2 pcs.) to remove the front panel. Be sure to use a Phillips screwdriver. 4. Undo the screws (2 pcs.) or press claw to remove the breaker cover. Be sure to use a Phillips screwdriver.
12.5 ([5m ] (a) (b) L E C P * B -* A B-1 2 A A-1 1 L B B-2 6 B A-2 5 1 1.5m COM-A/COM B-3 3 3 3m COM-B/ A-3 4 (c) 5 5m Shield Vcc B-4 12 GND A-4 13 A B-5 7 A A-5 6 B B-6 9 B A-6 8 3 (d) S 4 + B-1 5 A-1 1 + B-3 2 A-3 (8) (a) (b) (14.2) B1 A1 (17.7) 2 1 (14) (18) 6 (10.2) B6 5 A6 2 1 B1 A1 B3 A3 (d) (5.7) 15 16 (c) L (11) (30.7) 12.6 ([820m] (a) (b) LE CP * B A B-1
Proper use of the seal cap enables the enclosure to achieve IP67 specification. -29No.EX-OMN0028-B Specification Specifications Model EX600-ED2EX600-ED3Power connector M12 (5 pin) Plug 7/8 inch (5 pin) Plug Power Power supply (Control and input) 24 VDC 10% Class2, 2 A 24 VDC 10%, 8 A Power supply (Output) 24 VDC +10/-5% Class2, 2 A 24 VDC +10/-5%, 8 A Enclosure IP67 (With manifold assembled
Circuit (Class 2) of maximum 30 Vrms (42.4 V peak) or less, with UL1310 Class 2 power supply unit or UL1585 Class 2 transformer. The product is a UL approved product only if it has a mark on the body. Use the specified voltage. Otherwise failure or malfunction can result. Insufficient supply voltage may not drive a load due to a voltage drop inside the product.
0 @1 @2 @3 @0 e q t y u i r w !1 !8 !9 CX2N15, 25 q w e r t yu i o !0 @1 @2 @3 !2 !4 !5 !6 @0 !3 !7 Description Material Note Parts List Description Material Note Parts List No. No.
0 @1 @2 @3 @0 e q t y u i r w !1 !8 !9 CX2N15, 25 q w e r t yu i o !0 @1 @2 @3 !2 !4 !5 !6 @0 !3 !7 Description Material Note Parts List Description Material Note Parts List No. No.
3 @1 @3 @2 e o !8 @7 #0 !7 @6 r u #1 t @4 @5 #2 @0 y i !9 !0 q !1 w !
Proper use of the seal cap enables the enclosure to achieve IP67 specification. -30No.EX-OMN0034-B Specification Specifications Model EX600-ED2EX600-ED3Power connector M12 (5 pin) Plug 7/8 inch (5 pin) Plug Power Power supply (Control and input) 24 VDC 10% Class2, 2 A 24 VDC 10%, 8 A Power supply (Output) 24 VDC +10/-5% Class2, 2 A 24 VDC +10/-5%, 8 A Enclosure IP67 (With manifold assembled
0 A B NN-M6 X 1 thread 12 deep 6 1 26 5.1 9.5 10.5 10.5 A B 24 10.5 24 10.5 H (NN-1) X H G Cross section AA Cross section BB (mm) Model F 35 35 35 40 30 55 65 70 ZZ 87 87 87 97 112 162 210 260 M 76 76 76 86 101 151 199 249 Z 75 75 75 85 100 150 198 248 K 29 39 49 59 69 94 119 144 J 40 40 40 50 60 85 118 155 I 10 10 10 10 15 40 55 68 NN 2 2 2 2 3 4 5 7 H 40 40 40 50 30 35 35 35 G 16 16 16