SMC Corporation of America
Elite Part Number Search
Search Results "MGJ10-8"

Double wiring specification Double wiring specification 04 05 08 09 4 stations 8 stations 5 stations 9 stations Specified layout (up to 16 solenoids possible) Specified layout (up to 8 solenoids possible) ... ... ... ... 08 16 8 stations 16 stations Note 1) Double wiring specifications: Single, double and 3 position solenoid valves can be used at all of the manifold stations.

Note 2) Number of terminals 1 2 8 terminals in 1 row 16 terminals in 2 rows 1 to 4 stations (double), 8 stations (single) 5 to 8 stations (double), 16 stations (single) Note) The number of terminal blocks can be chosen regard-less of station qty.

C6 (One-touch fitting for 6) C8 (One-touch fitting for 8) B7 (One-touch fitting for 1/4") C9 (One-touch fitting for 5/16") Port size Rc 1/8 4(A), 2(B) port Flow Characteristics Port size Manifold C [dm 3/(sbar)] b Cv C [dm 3/(sbar)] b Cv Flow characteristics 1 4/2 (P A/B) 4/2 5/3 (A/B R) 1(P), 5/3(R) port 2(B), 4(A) port VV5Z5-40 VV5Z5-41 VV5Z5-42-C6 VV5Z5-42-C8 1/8 1/8 C6 C8 0.59 0.55

3000 12.5 15 1/4 1/4 30 =0.7 6 10 1/4, 3/8 500 4 20 0.5 0.1 0.3 AS3000, AS3500 (12.3) AS4001F (16) AS320 (13) 10 10 1/4, 3/8 32 1000 8 REA AS3000,AS3500 (12.3) AS4000 (25.5) AS5000 (74) AS5000 (74) AS5000 (74) AS321F (10) AS331F (10) AS4001F (16) AS320 (13) 1500 2000 2500 3000 12 16 20 24 1/4, 3/8 3/8 3/8 3/8 0 REB 1,000 2,000 3,000 Maximum speed Vmax (mm/s) REC 40 8 10 1/4, 3/8 CY 500 40

Port Size Ejector system Vacuum pump system Metric Inch Metric Inch PV 6 1/4" 6 1/4" V 6, 8 1/4", 5/16" 6, 8 1/4", 5/16" EXH (Port exhaust) 8 5/16" If the sound absorbing material is clogged, it will cause a reduction in the ejector performance.

(mm) Connection thread R Model A M Weight (g) Note) D2 L1 L2 10 D1 KRL06-02S KRL06-01S 1 8 12 22 33 13 21 35 25 26 36 25.5 23 27 29 24.5 28.5 30.5 27 30 32 36 31 33 37 10 20 29 27.5 1 4 19 4.2 14 17 12 14 17 12.8 6 Applicable tubing 9.0 3 8 1 8 KRL06-03S 28 14.9 KRL08-01S KRL08-02S KRL08-03S KRL10-01S KRL10-02S KRL10-03S 1 4 3 8 1 8 1 4 3 8 30 31.5 32 33 34.5 15.2 12 23 8 20.5 21.6 14.9 21.6

47 32 13 10 55 45 10 17 45.5 186 40 6 8 37.5 5.5 8 6.8 28 D32 M10 x 1.25 22 22 19.5 42.5 47 32 13 11 55 45 12 17 49.5 199 40 6 8 46.5 5.5 10 6.8 28 40 M14 x 1.5 24 26.5 21 51 54 41 16 12.5 75 50 14 22 55.5 227 55 8 10 56.2 7 12 7 30 -X NN P S X Y Z ZZ Bore (mm) 20 M20 x 1.5 1/8 146 20 8 21 215 Individual -X 25 M26 x 1.5 1/8 146 20 8 25 219 32 M26 x 1.5 1/8 159 20 8 25 232 40 M32 x 2 1/4 181

47 32 13 10 55 45 10 17 45.5 186 40 6 8 37.5 5.5 8 6.8 28 D32 M10 x 1.25 22 22 19.5 42.5 47 32 13 11 55 45 12 17 49.5 199 40 6 8 46.5 5.5 10 6.8 28 40 M14 x 1.5 24 26.5 21 51 54 41 16 12.5 75 50 14 22 55.5 227 55 8 10 56.2 7 12 7 30 -X NN P S X Y Z ZZ Bore (mm) 20 M20 x 1.5 1/8 146 20 8 21 215 Individual -X 25 M26 x 1.5 1/8 146 20 8 25 219 32 M26 x 1.5 1/8 159 20 8 25 232 40 M32 x 2 1/4 181

47 32 13 10 55 45 10 17 45.5 186 40 6 8 37.5 5.5 8 6.8 28 D32 M10 x 1.25 22 22 19.5 42.5 47 32 13 11 55 45 12 17 49.5 199 40 6 8 46.5 5.5 10 6.8 28 40 M14 x 1.5 24 26.5 21 51 54 41 16 12.5 75 50 14 22 55.5 227 55 8 10 56.2 7 12 7 30 -X NN P S X Y Z ZZ Bore (mm) 20 M20 x 1.5 1/8 146 20 8 21 215 Individual -X 25 M26 x 1.5 1/8 146 20 8 25 219 32 M26 x 1.5 1/8 159 20 8 25 232 40 M32 x 2 1/4 181

inputs) 2 0 EX600-DY#B (8 outputs) 0 1 EX600-DY#E Digital output unit (16 outputs) 0 2 EX600-DY#F (16 outputs) 0 2 EX600-DM#E (8 inputs/8 outputs) 1 1 Digital I/O unit EX600-DM#F (8 inputs/8 outputs) 1 1 -79No.EX-OMA1023 Allocated bytes (continued) Allocated bytes Unit Unit part number Input Output EX600-AXA 4 (2 bytes per channel) 0 (2 channels) Analogue input Unit EX600-AXB 8 (2 bytes per

ZPT04U 4 4.8 1.6 3 6 5 8 0.8 D E E P T Y P E ZPT06U 6 7 2.5 3 6 5 8 0.8 Model A B C D E F G Y ZPT08U 8 9 2.5 3 6 5 8 1 ZPT10D 10 12 15 24 35.5 58.5 71.5 6 ZPT16D 16 18 16 25 36.5 59.5 72.5 7 Courtesy of Steven Engineering, Inc. !

Flow Rate and Effective Area AS12 1F-M3 AS13 1F-M3 AS12 1F-M5 AS13 1F-M5 AS22 1F-01 AS23 1F-01 AS22 1F-02 AS23 1F-02 AS32 1F AS33 1F AS42 1F AS43 1F Model Metric size 3.2, 4 3.2, 4, 6 3.2, 4 6, 8, 10 8,10 4 6 6 8 10 12 10, 12 Tubing O.D. 1/8" 5/32" 1/8", 3/16" 1/8" 5/32" 3/16", 1/4" 5/16" 1/4", 5/16" 3/8" Inch size 5/32" 3/16" 5/16" 3/8" 1/2" 3/8" 1/4" 1/4", 5/32" Controlled flow (Free flow

Class Symbol PAF341S 12 x 10 10 x 8 19 x 16 12 x 10 25 x 22 19 x 16 PAF541S PAF341S PAF541S tubing size (mm) tubing size (inch ) SMC SMC SMC 4 4 5 5 6 6 1 2 1 2 1 2 4 4 5 5 6 6 A B A B A B 1/2" x 3/8" 3/8" x 1/4" Panel mount union U P 3/4" x 5/8" Union 1/2" x 3/8" 1" x 7/8" 3/4" x 5/8" SMC Note) Select the fitting after confirming the IN / OUT side fitting size and fitting type.

Valve stations Port size Body size Pilot type Applicable valve Valve stations Port size Body size Pilot type 1 (P) Port 3 (R) 2 (A) 2 2 1 Internal pilot VEX3222 Solenoid Air operated: VEX3220 Note) 6 2 02 1 4 6 2 Common external pilot Air operated 8 8 2 A B C 6 VEX3422 3 8 1 4 2 1 Internal pilot Air operated: VEX3420 Note) 4 3 8 2 Common external pilot 1 2 3 8 VEX 6 VEX3 manifold (Size

Metric size Inch size 3.2 01 03 05 07 09 11 23 04 06 08 10 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" Control type 4 6 8 10 0 1 Meter-out Meter-in Use 1/8" tube.