Valve; Stop Valve: None), Return Port Size: 04 (1/2), Flow Switch Output Specifications: DT (Out 1: NPN; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Flow Switch Unit Specifications: M (Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display IO-Link: L/min; Accumulated Flow: L; Temp
Valve; Stop Valve: None), Return Port Size: 04 (1/2), Flow Switch Output Specifications: DT (Out 1: NPN; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Flow Switch Unit Specifications: M (Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display IO-Link: L/min; Accumulated Flow: L; Temp
Valve; Stop Valve: None), Return Port Size: 04 (1/2), Flow Switch Output Specifications: DT (Out 1: NPN; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Flow Switch Unit Specifications: M (Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display IO-Link: L/min; Accumulated Flow: L; Temp
.: Switch Output (N/P); Temperature Sensor: Yes], Lead Wire: Q (w/M12 -M8 Conversion Lead Wire, 0.1 m), Flow Switch Unit Specifications: M (Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display IO-Link: L/min; Accumulated Flow: L; Temp.: °C)
.: None; Temperature Sensor: Yes], Lead Wire: N (w/o Lead Wire and M8 Connector), Flow Switch Unit Specifications: M (Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display IO-Link: L/min; Accumulated Flow: L; Temp.: °C)
.: None; Temperature Sensor: None), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Flow Switch Unit Specifications: M (Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display IO-Link: L/min; Accumulated Flow: L; Temp.: °C)
Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: S (w/Flow Adjustment), Port Size: 04 (TSJ1/2, Compression Fitting), Output Specification/Temperature Sensor: D (Out 1: NPN; Out 2: Analog 4-20 mA), Lead Wire: with Lead Wire with M8 Connector, 3 m, Unit Specification: M (Instantaneous Flow: L/min; Accumulated Flow: L; Temperature: °C), Bracket: None, Calibration Certificate: None
Rated Flow Range: 04 (0.5 to 4 L/min), Flow Adjustment Valve: w/o Flow Adjustment, Port Size: 03 (TSJ3/8, Compression Fitting), Output Specification/Temperature Sensor: A (Out 1: NPN; Out 2: None), Lead Wire: with Lead Wire with M8 Connector, 3 m, Unit Specification: M (Instantaneous Flow: L/min; Accumulated Flow: L; Temperature: °C), Bracket: None, Calibration Certificate: None
Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: S (w/Flow Adjustment), Port Size: 04 (TSJ1/2, Compression Fitting), Output Specification/Temperature Sensor: BT (Out 1: PNP; Out 2: Flow Rate PNP; Temperature: PNP; w/Temperature Sensor), Lead Wire: N (w/o Lead Wire with M8 Connector, 3 m), Unit Specification: M (Instantaneous Flow: L/min; Accumulated Flow: L; Temperature: °C),
Normally Closed), Seal Material: A (NBR), Pressure Range: 05 (0 to 0.5 MPa), Thread: Rc, Port Size: 15 (1/2), Pilot Valve: Y (0.35 W Type, V116), Voltage: 1 (100 VAC 50/60 Hz), Electrical Entry: T (Conduit Terminal), Surge Suppressor: Z (With Light and Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Bracket Mounting Position: B1 (Bracket on the Left Side), Auto Switch: M
Type: 1 (Normally Closed), Seal Material: A (NBR), Pressure Range: 05 (0 to 0.5 MPa), Thread: Rc, Port Size: 15 (1/2), Pilot Valve: Y (0.35 W Type, V116), Voltage: 5 (24 VDC), Electrical Entry: T (Conduit Terminal), Surge Suppressor: Z (With Light and Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Bracket Mounting Position: B1 (Bracket on the Left Side), Auto Switch: M
(Normally Closed), Seal Material: A (NBR), Pressure Range: 10 (0 to 1 MPa), Thread: Rc, Port Size: 15 (1/2), Pilot Valve: Y (0.35 W Type, V116), Voltage: 1 (100 VAC 50/60 Hz), Electrical Entry: T (Conduit Terminal), Surge Suppressor: Z (With Light and Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Bracket Mounting Position: B1 (Bracket on the Left Side), Auto Switch: M
Body Size & Pressure Range: 2050 (AMS20A/30A), Input Signal: IL (IO-Link), Size: 20, Actuation: 2 (Normally Open), Pressure Display Unit: M (SI Units Only)
Body Size & Pressure Range: 2050 (AMS20A/30A), Input Signal: IL (IO-Link), Size: 30, Actuation: 1 (Normally Closed), Pressure Display Unit: M (SI Units Only)
Body Size & Pressure Range: 3050 (AMS40A/60A), Input Signal: IL (IO-Link), Size: 40, Actuation: 2 (Normally Open), Pressure Display Unit: M (SI Units Only)
Body Size & Pressure Range: 3050 (AMS40A/60A), Input Signal: IL (IO-Link), Size: 40, Actuation: 1 (Normally Closed), Pressure Display Unit: M (SI Units Only)
Body Size & Pressure Range: 2050 (AMS20A/30A), Input Signal: IL (IO-Link), Size: 30, Actuation: 2 (Normally Open), Pressure Display Unit: M (SI Units Only)
Body Size & Pressure Range: 3050 (AMS40A/60A), Input Signal: IL (IO-Link), Size: 60, Actuation: 2 (Normally Open), Pressure Display Unit: M (SI Units Only)
Body Size & Pressure Range: 2050 (AMS20A/30A), Input Signal: IL (IO-Link), Size: 20, Actuation: 1 (Normally Closed), Pressure Display Unit: M (SI Units Only)
Body Size & Pressure Range: 3050 (AMS40A/60A), Input Signal: IL (IO-Link), Size: 60, Actuation: 1 (Normally Closed), Pressure Display Unit: M (SI Units Only)