Please consult with SMC. 2) Install an air filter. Install an air filter upstream near the valve.

Low frequency operation Install an air filter upstream near the valve. Select an air filter with a filtration size of 5 m or smaller. 4. If excessive carbon powder is seen, install a mist separator on the upstream side of the valve. If excessive carbon dust is generated by the compressor, it may adhere to the inside of a valve and cause it to malfunction.

Furthermore, since valves and cylinders are not guaranteed for zero air leakage, it may not be possible to It may cause human injury and/or an accident. hold a stopped position for an extended period of time. 1. Momentary energization Please contact SMC if it is necessary to hold a stopped Caution position for an extended period of time. 4.

Install an air filter. I Install an air filter upstream near the valve. Select an air filter with a filtration size of 5 m or smaller. 4. If the volume of air leakage increases or the valve does not operate normally, do not use the valve. Perform periodic maintenance on the valve to confirm the operating condition and check for any air leakage. 3.

-M5 G H Manual override (Non-locking) (Lead wire length) Mounting hole for manifold G: 300 mm H: 600 mm (Mounting hole) (PE port) (Piping port) L plug connector (L) VZ3220-L-M5 M plug connector (M) VZ3220-M-M5 300 (Lead wire length) 300 (Lead wire length) : With light/surge voltage suppressor DIN terminal (D) VZ3220-D-M5 C4 C6 Built-in One-touch fittings VZ3220-MAX. 10 C4: MAX. 7 C6: MAX.

Install an air filter. Install an air filter upstream near the valve. Select an air filter with a filtration size of 5 m or smaller. 3. Take measures to ensure air quality, such as by installing an aftercooler, air dryer, or water separator. Compressed air that contains a large amount of drainage can cause malfunction of pneumatic equipment such as air grippers.

Select an air filter with a filtration size of 5 m or smaller. Take measures to ensure air quality, such as by installing an aftercooler, air dryer, or water separator. Compressed air that contains a large amount of drainage can cause malfunction of pneumatic equipment such as valves.

Do not use the product in an environment where corrosive gases or fluids could be splashed. Otherwise damage to the product and malfunction can result. Do not use in an area where surges are generated.

This function gives an alarm if a critical error happens, the display shows ERR and an alarm number. At the same time, the warning output connector gives an output through a relay contact. This warning cannot be removed unless the power is cycled. When the power is being cycled leave at least 3 seconds between turning the power off and turning the power back on. Nov y Ty Uy Vy .

ZSP ISA2 Fig. (2) Equivalent circuit of an NPN switch with the output off PLC Low level 12 to 24 [VDC] IS Main circuit of switch Max. 80 [mA] Max. 30 [V] ZSM Load PF2 Current flows. Load is powered. IF Fig. (3) Equivalent circuit of an NPN switch with the output on Data PNP 12 to 24 [VDC] Fig. (4) shows an example of a PNP switch.

Work piece weight (kg) 10 10 5 5 1 1kg 1 0.25kg 0.1 10 20 40 0.1 5 10 20 30 Transfer speed (m/min) Transfer speed (m/min) 32.5m/min 12m/min Procedure3 Confirmation of allowable lateral load MIW12 MIS12 1. Calculation of applied lateral load F F = N m g (N) = 0.2 x 10 x 0.1 x 9.8 = 2.1 (N) 1.

Install an air filter. Install an air filter upstream near the valve. Select an air filter with a filtration size of 5 m or smaller. 3. Take measures to ensure air quality, such as by installing an aftercooler, air dryer, or water separator. Compressed air that contains a large amount of drainage can cause the malfunction of pneumatic equipment, such as air grippers.

Install an air dryer, after cooler, etc. Air that includes excessive condensate may cause malfunction of valves and of other pneumatic equipment. To prevent this, install an air dryer, after cooler, etc. 10 - 3 Use the product within the specified range of fluid and ambient temperature.

The filtration degree should be 5 m or less. Install an after cooler, air dryer, drain catch, etc. Air that includes excessive condensate may cause malfunction of valves and other pneumatic equipment. To prevent this, install an air dryer, after cooler, etc. Use the product within the specified range of fluid and ambient temperature.

Serial Data Transfer Multiple pieces of information transmitted one piece at a time Signal An electro-magnetic transmission that indicates or represents an occurrence. Tee A product that creates a single branch or drop from a bus. Trunk line The main bus line.

Do not use the product in an environment where corrosive gases or fluids could be splashed. Otherwise damage to the product and malfunction can result. Do not use in an area where surges are generated.

Install an air filter. Install an air filter upstream near the valve. A filtration degree of 5m or less should be selected. 3. Install an aftercooler, air dryer or drain catch before the filter and take appropriate measures. Compressed air that contains excessive foreign material may cause malfunction of valves and other pneumatic equipment.

An unexpected malfunction in the system composition devices is likely to occur due to the malfunction of machinery or equipment. 3. After maintenance, make sure to perform an appropriate functionality inspection. In the case of an abnormality such as a faulty operation, stop operation at once. An unexpected malfunction in the system composition devices is likely to occur. 4.