SMC Corporation of America
Elite Part Number Search
Search Results "CXSL15-90-Y7PSAPC"

For the grease, we recommended using high-quality lithium soap based grease no. 2 13) Mounting orientation (In the case of rear plate) If the guide body is mounted so that it is inclined more than 90, the rear plate may interfere with the basic cylinder head end due to the deflection of guide rods.

Center C Clevis trunnion 0.5 71 61 76 75 88 109 113 CD T D 0.7 59 50 62 61 72 89 92 0.3 135 119 147 146 167 208 217 0.5 101 89 111 110 127 158 164 T 0.7 84 74 91 91 105 131 136 Rod side 0.3 301 267 330 324 370 460 483 Head L Foot: side Frang flange e F 0.5 231 207 253 248 284 354 371 L G F 0.7 193 172 212 208 239 297 311 0.3 144 126 156 154 177 220 230 0.5 109 94 118 116 134 167 174 G 0.7 90

Changing the entry direction The cable entry direction of a connector can be changed as desired (4 directions at 90 intervals), depending on the combination of a housing (4) and a terminal block (3). 2) Wire the terminal block in the terminal box with power source side. (See figure on right). The thread size of terminal block is M4.

1.2 28 42.5 75.7 42.5 3/4 1/8 44.3 AW60-B 95 234.1 175.5 47.5 30 47.5 3.2 28 42.5 80.8 42.5 1 1/8 Optional Bracket mount dimensions Panel mount dimensions Model Q S T U AW20-B 30 34 43.9 5.4 15.4 55 2.3 24.7 28.5 14 6 AW30-B 41 40 45.8 6.5 8 53 2.3 31.1 38.5 19 7 AW40-B 50 54 54 8.5 10.5 70 2.3 35.5 42.5 21 7 AW40-06-B 50 54 55.5 8.5 10.5 70 2.3 37 42.5 21 7 AW60-B 70 66 65.8 11 13 90

The graphs below show the response time when the workpiece is approached at 90% distance and 0% distance (close contact). (: The switch point is 100% distance) (Example: When the switch point is set to 0.1 mm, the response time when the workpiece is at 0.09 mm and 0.00 mm are measured).

D-A9V D-M9WV D-Y7PV D-P3DWA D-P3DW D-P4DW D-Y59/Y7P D-M9AV D-Y7WV D-Y7W D-Y7BA Bore size (mm) Hs Hs Ht Hs Ht Hs Ht Hs Ht Hs Ht Hs Ht 20 18.5 22 24.5 20 25 20.5 24 26 21.5 32 30 32 23 26.5 29 24.5 35 33 41.5 40 27 30.5 33 28.5 39 37 44.5 50 32.5 36 38.5 34 44.5 42.5 50 63 39.5 43 45.5 41 51.5 49.5 57 80 40 43 71.5 45 74 41 70 49.5 84 48 78.5 61 84.5 100 50 53 83 55 85.5 51 81.5 60 95 58 90

The angle adjustment range of the bracket is 45 degrees in direction A, and 90 degrees in direction B. Direction B: 90o Direction A: 45o M5 2) Installation without bracket If a bracket is not used, install the product using the M4 screw holes on both sides of the body. Make sure to secure both sides of the body when fixing the Ionizer.

Middle stroke 120 Long stroke 60 Lubrication Not required Action Double acting Note 2) Gripping force Effective gripping force per finger (N) 19 48 90 141 Short stroke 8 12 16 20 Opening/closing stroke (Both sides) (mm) Middle stroke 16 24 32 40 Long stroke 32 48 64 80 Short stroke 65 155 350 645 Note 3) Weight (g) Middle stroke 85 190 445 850 Long stroke 120 275 650 1,225 Note1) This is

While down, turn clockwise 90 to lock it. Turn it counterclockwise to release it. Slide locking type (Manual Type) (SQ2000 only) The manual override is locked by sliding it all the way to the pilot valve side (ON side) with a small flat head screwdriver or fingers. Slide it to the fitting side (OFF side) to release it.

(The ZFC1 series is not equipped with a lock mechanism.) (3) Rotate the cover counterclockwise at least 90 degrees. (4) Pull out the cover from the body to remove the element. Eliminate the dust stuck to the internal surface of the body with air blow.

Panel mount adapter (Model: ZS-27-C) Panel mount adapter + Front protective cover (Model: ZS-27-D) : The panel mount adapter can be rotated by 90 degrees for mounting. Note when removing the switch The Pressure switch with panel mount adapter can be removed from the installation by removing 2 screws and releasing the hooks at the sides, as illustrated.

Change of electrical entry (Orientation) After separating terminal block and housing, the cable entry direction can be changed by attaching the housing in the desired direction (4 directions in 90 increments). Piping In the case of w/ indicator light, avoid damaging the light with lead wire.

Exterior dimensions C D XMA Series Angle Valve Fd Fn Fc C Fc L1 KF Flange K Flange CF Flange ( K ) ( K F ) ( C F ) L2 H B G A A Unit:mm Model n Fd Fc H P.C.D L1 L2 XMA-16 40 103 38 1 30 34 17 40 P.C.D 27 6x4.4 XMA-25 50 113 48 1 40 26 39 XMA-40 65 158 66 2 55 70 41 63 P.C.D. 58.7 6x6.6 XMA-50 70 170 79 2 75 52 68 XMA-63 88 196 100 3 87 95 114 70 69 P.C.D. 92.1 8x8.4 XMA-80 90 235 117 3 114

for retraction When the cylinder is extended KA: T-slot for hexagon bolt 4-M K KB KC 6-K (6 positions) 9 9 M12 x 1.75 M10 x 1.5 M8 x 1.25 M Bore size Standard stroke (mm) 170 140 10 10 38 38 36.5 E B F KC GB D A 11 11 8.7 120 X T V M6 M6 M5 18.5 KA KB 46 46 38 PP 70 50 M12 x 1.75 M10 x 1.5 M8 x 1.25 N H GA C 1/4 1/4 1/8 40 P 100 63 30, 50,75, 100 40 78 73 58 66.5 61.5 48.5 4 4 3.5 8 100 90

size B C FA FB FC FD FE FF FG FH G H 12 42 29 7 6 80 89 18 25 4.5 5 26 58 16 46 33 7 6 88 98 22 32 5.5 5 30 64 20 53 37 8 8 102 112 24 38 5.5 6 36 83 25 53.5 37.5 9 7 114 126 30 40 6.6 6 42 93 32 59.5 37.5 10 12 138 154 34 50 9 9 48 112 40 66 44 10 12 146 162 40 60 9 9 54 120 50 72 44 12 16 178 198 46 65 11 10 64 148 63 77 49 12 16 192 212 58 75 11 10 78 162 80 96.5 56.5 16 24 238 262 54 90

As a rule, it should be turned about 90 beyond the point at which tightening can be felt. When auto switches D-M9/M9W/Y59 D-M9A D-Y7, Y7W are used A B L Auto Switch Hysteresis MHZ When auto switches D-M9V/M9WV/Y69 D-M9AV D-Y7V, Y7WV are used Auto switches have hysteresis similar to micro switches. Use the table below as a guide when adjusting auto switch positions, etc.

Turn another 90 from the position where tightening is felt by hand.

Shock absorber model Applicable bore (mm) CLS ML1-A25H ML1-A32H ML1-A40H ML1C25 ML1C32 ML1C40 101 90 25 20 11 72 67.3 12 31 39.5 Max. 16.5 4.5 3 RB1412 120 107 30 25 16 93 73.2 15 38 49 Max. 20 5.5 6 CLQ RB2015 147 129 30 31 16 105.5 73.2 15 40.5 54.5 Max. 25 5.5 6 MLGP Side Support RLQ Side support A MLU ML1C D-X 20Data Side support B A B C D E F G H J Part no.

Shock absorber model Applicable bore (mm) CLS ML1-A25H ML1-A32H ML1-A40H ML1C25 ML1C32 ML1C40 101 90 25 20 11 72 67.3 12 31 39.5 Max. 16.5 4.5 3 RB1412 120 107 30 25 16 93 73.2 15 38 49 Max. 20 5.5 6 CLQ RB2015 147 129 30 31 16 105.5 73.2 15 40.5 54.5 Max. 25 5.5 6 MLGP Side Support RLQ Side support A MLU ML1C D-X 20Data Side support B A B C D E F G H J Part no.

Applicable bore Shock absorber model ML1-A25H ML1-A32H ML1-A40H ML1C25 ML1C32 ML1C40 101 90 25 20 11 72 67.3 12 31 39.5 Max. 16.5 4.5 3 RB1412 120 107 30 25 16 93 73.2 15 38 49 Max. 20 5.5 6 RB2015 147 129 30 31 16 105.5 73.2 15 40.5 54.5 Max. 25 5.5 6 Side Support Side support A 2 x G E E F 2 x H A B Side support B 2 x J A B (mm) A B C D E F G H J Part no.