Box 6165 Karachi 74000 Pakistan TEL: 021-243-9070/8449 FAX: 021-241-4589 ISRAEL (Distributor) Baccara Automation Control Kvutzat Geva 18915 Israel TEL: 04-653-5960 FAX: 04-653-1445 SAUDI ARABIA (Distributor) Assaggaff Trading Est. P.O. Box 3385 Al-Amir Majed Street, Jeddah-21471, Saudi Arabia TEL: 02-6761574 FAX: 02-6708173 15-18-21
Metric size Inch size Applicable model SRF10 SRF30 SRF50 Applicable model SRF10 SRF30 SRF50 Applicable tubing size Applicable tubing size Symbol Symbol 04 06 08 10 12 19 03 05 07 11 13 19 4 x 3 6 x 4 8 x 6 10 x 8 12 x 10 19 x 16 1/8" x 0.086" 3/16" x 1/8" 1/4" x 5/32" 3/8" x 1/4" 1/2" x 3/8" 3/4" x 5/8" : Basic size : With reducer : Basic size : With reducer Note) Tubing size is interchangeable
JIS Symbol Accessory/Option Model Auto-drain Companion flange AT6C AT11C AT22C AT37C AT55C AT75C AT125C AT150C AT220C Precautions AD402-04 2BJIS10KFF Be sure to read before handling.
Drain outlet (B) Heavy duty auto drain 1/2 (ADH4000-04) Note) The heavy duty auto drain and the drain valve are both enclosed in the same shipping package as the main body of the air dryer. The customer is required to mount the parts to the air dryer. 8 10 Series IDF/IDU E Option Specifications 2 Refer to pages 2 and 5 for How to Order of options.
A dryer with heavy duty auto-drain (ADH4000-04) is installed instead of the float type auto-drain (AD44). Option symbol R With circuit breaker A circuit breaker is attached to the side of the air dryer.
Conditions: Operating pressure 0.5 MPa, Operating oil Turbine oil Class 1 (ISO VG32), Piping length 1 m AS500-06 AS420-02/03/04 Piping bore Piping bore Cylinder driving speed (mm/s) Cylinder driving speed (mm/s) No load No load Load ratio Load ratio Bore size (mm) Bore size (mm) Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588
(Including band and screw) Operating Range Bore size (mm) Bore size (mm) Auto switch model Auto switch model 20 25 32 40 50 20 25 32 40 50 D-C7/C8 D-H7 D-B5/B6 D-G5/K5 D-B7/B8 D-G7/K7 D-B7/B80 BMA2 -025 BMA2 -032 BMA2 -040 BMA2 -050 BMA2 -020 10 8 10 9 10 D-B73C/B80C D-C7/C80 BA -32 BA -04 BA -05 BA -01 BA -02 10 8 10 9 10 D-C73C/C80C D-B5/B64 BM1 -01 BM1 -02 BM1 -32 BM1 -04 BM1 -05 10 8
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com D-H7 D-G59F 5 5 5.5 6 7 7.5 8 7.5 D-B5/B6 BA -04 BA -05 BA -06 BA -08 BA -10 BA -32 BA -02 BA -01 CX D-G5NBL 35 40 45 45 45 40 50 45 D-G5/K5 D-B7/B8 BM1 -01 BM1 -02 BM1 -32 BM1 -04 BM1 -05 BM1 -06 Since this is a guideline including hysteresis, not meant
BM1 -01 BM1 -02 BM1 -32 BM1 -04 Intermediate strokes and short strokes other than the above are produced upon receipt of order.
Stations: 04 (4 Stations), Piping: D (U Side: Closed; D Side: Open), Thread Type: N (NPT), Supply Unit Components: W (w/Flow Adj. Valve; w/Stop Valve), Return Unit Flow Switch: 5 (Remote Sensor Unit), Return Unit Flow Range: 04 (0.5 to 4 L/min), Return Unit Components: W (w/Flow Adj.
Stations: 04 (4 Stations), Piping: D (U Side: Closed; D Side: Open), Thread Type: Rc, Supply Unit Components: P (w/o Flow Adj. Valve; w/Stop Valve), Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 20 (2 to 16 L/min), Return Unit Components: W (w/Flow Adj.
Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: 2T (Out 1: Analog 4 to 20 mA; Out 2: Flow Rate: None; Temp.: Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: Q (w/M12 -M8 Conversion Lead Wire, 0.1 m)
Stations: 04 (4 Stations), Piping: D (U Side: Closed; D Side: Open), Thread Type: Rc, Supply Unit Components: W (w/Flow Adj. Valve; w/Stop Valve), Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 20 (2 to 16 L/min), Return Unit Components: P (w/o Flow Adj.
Stations: 04 (4 Stations), Piping: D (U Side: Closed; D Side: Open), Thread Type: F (G), Supply Unit Components: W (w/Flow Adj. Valve; w/Stop Valve), Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 20 (2 to 16 L/min), Return Unit Components: Flow Adj.
Stations: 04 (4 Stations), Piping: U (U Side: Open; D Side: Closed), Thread Type: N (NPT), Supply Unit Components: Flow Adj. Valve: None; Stop Valve: None, Return Unit Flow Switch: 5 (Remote Sensor Unit), Return Unit Flow Range: 04 (0.5 to 4 L/min), Return Unit Components: S (w/Flow Adj.
Valve: None; Stop Valve: None, Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: 2T (Out 1: Analog 4 to 20 mA; Out 2: Flow Rate: None; Temp.: Analog 4 to 20 mA; Temperature Sensor: Yes)
Stations: 04 (4 Stations), Piping: B (U Side: Open; D Side: Open), Thread Type: N (NPT), Supply Unit Components: W (w/Flow Adj. Valve; w/Stop Valve), Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 20 (2 to 16 L/min), Return Unit Components: P (w/o Flow Adj.
Stations: 04 (4 Stations), Piping: B (U Side: Open; D Side: Open), Thread Type: N (NPT), Supply Unit Components: P (w/o Flow Adj. Valve; w/Stop Valve), Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 20 (2 to 16 L/min), Return Unit Components: P (w/o Flow Adj.
Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: 1T (Out 1: Analog 1 to 5 V; Out 2: Flow Rate: None; Temp.: Analog 1 to 5 V; Temperature Sensor: Yes)
Stations: 04 (4 Stations), Piping: D (U Side: Closed; D Side: Open), Thread Type: N (NPT), Supply Unit Components: P (w/o Flow Adj. Valve; w/Stop Valve), Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 20 (2 to 16 L/min), Return Unit Components: P (w/o Flow Adj.