SMC Corporation of America
Elite Part Number Search
Search Results "SS5J3-60-07B"

Fluid: air and inert gas, Operating pressure: 0.1MPa to 1.0MPa, Effective area (Cv): 2.2 to 5.7, Coil rated voltage: 100, 200 VAC 50/60Hz; 24VDC, Response time: 60 or less ms, Ambient/fluid temp: -10 to 60 C, VALVE, DBL NON PLUGIN BASE MT, VALVE, VFS5000 SOL VALVE 4/5 PORT, 2F, VFS5000, 4.1636 lb

Fluid: air and inert gas, Operating pressure: 0.1MPa to 1.0MPa, Effective area (Cv): 2.2 to 5.7, Coil rated voltage: 100, 200 VAC 50/60Hz; 24VDC, Response time: 60 or less ms, Ambient/fluid temp: -10 to 60 C, VALVE DBL NON PLUGIN BASE MT, VALVE, VFS5000 SOL VALVE 4/5 PORT, 2F, VFS5000, 2.81512 lb

Fluid: air and inert gas, Operating pressure: 0.1MPa to 1.0MPa, Effective area (Cv): 2.2 to 5.7, Coil rated voltage: 100, 200 VAC 50/60Hz; 24VDC, Response time: 60 or less ms, Ambient/fluid temp: -10 to 60 C, VALVE DBL NON PLUGIN BASE MT, VALVE, VFS5000 SOL VALVE 4/5 PORT, QF, VFS5000 BASE MT 3/8, 4.29522 lb

Fluid: air and inert gas, Operating pressure: 0.1MPa to 1.0MPa, Effective area (Cv): 2.2 to 5.7, Coil rated voltage: 100, 200 VAC 50/60Hz; 24VDC, Response time: 60 or less ms, Ambient/fluid temp: -10 to 60 C, VALVE DBL PLUGIN BASE MOUNT, VALVE, VFS5000 SOL VALVE 4/5 PORT, 2G, VFS5000, 2.64554 lb

Fluid: air and inert gas, Operating pressure: 0.1MPa to 1.0MPa, Effective area (Cv): 2.2 to 5.7, Coil rated voltage: 100, 200 VAC 50/60Hz; 24VDC, Response time: 60 or less ms, Ambient/fluid temp: -10 to 60°C, VALVE DBL PLUGIN BASE MOUNT, VALVE, VFS5000 SOL VALVE 4/5 PORT, 2G, VFS5000, 2.47409 lb

Fluid: air and inert gas, Operating pressure: 0.1MPa to 1.0MPa, Effective area (Cv): 2.2 to 5.7, Coil rated voltage: 100, 200 VAC 50/60Hz; 24VDC, Response time: 60 or less ms, Ambient/fluid temp: -10 to 60 C, VALVE DBL NON PLUGIN BASE MT, VALVE, VFS5000 SOL VALVE 4/5 PORT, QG, VFS5000 BASE MT 3/8, 4.40924 lb

Fluid: air and inert gas, Operating pressure: 0.1MPa to 1.0MPa, Effective area (Cv): 2.2 to 5.7, Coil rated voltage: 100, 200 VAC 50/60Hz; 24VDC, Response time: 60 or less ms, Ambient/fluid temp: -10 to 60 C, VALVE DBL NON PLUG-IN BASE MT, VALVE, VFS5000 SOL VALVE 4/5 PORT, RG, VFS5000 BASE MT 1/2, 1.76369 lb

Fluid: air and inert gas, Operating pressure: 0.1MPa to 1.0MPa, Effective area (Cv): 2.2 to 5.7, Coil rated voltage: 100, 200 VAC 50/60Hz; 24VDC, Response time: 60 or less ms, Ambient/fluid temp: -10 to 60 C, VALVE DBL NON PLUGIN BASE MT, VALVE, VFS5000 SOL VALVE 4/5 PORT, SG, VFS5000 BASE MT 3/4, 4.88008 lb

Fluid: air and inert gas, Operating pressure: 0.1MPa to 1.0MPa, Effective area (Cv): 2.2 to 5.7, Coil rated voltage: 100, 200 VAC 50/60Hz; 24VDC, Response time: 60 or less ms, Ambient/fluid temp: -10 to 60 C, VALVE, DBL SOL, PLUG-IN, VALVE, VFS5000 SOL VALVE 4/5 PORT, SI, VFS5000 BASE MT 3/4, 5.25152 lb

Fluid: air and inert gas, Operating pressure: 0.1MPa to 1.0MPa, Effective area (Cv): 2.2 to 5.7, Coil rated voltage: 100, 200 VAC 50/60Hz; 24VDC, Response time: 60 or less ms, Ambient/fluid temp: -10 to 60 C, VALVE DBL NON PLUGIN BASE MT, VALVE, VFS5000 SOL VALVE 4/5 PORT, 2I, VFS5000, 1.606 lb

Fluid: air and inert gas, Operating pressure: 0.1MPa to 1.0MPa, Effective area (Cv): 2.2 to 5.7, Coil rated voltage: 100, 200 VAC 50/60Hz; 24VDC, Response time: 60 or less ms, Ambient/fluid temp: -10 to 60 C, VALVE DBL NON PLUGIN BASE MT, VALVE, VFS5000 SOL VALVE 4/5 PORT, RI, VFS5000 BASE MT 1/2, 4.29901 lb

Fluid: air and inert gas, Operating pressure: 0.1MPa to 1.0MPa, Effective area (Cv): 2.2 to 5.7, Coil rated voltage: 100, 200 VAC 50/60Hz; 24VDC, Response time: 60 or less ms, Ambient/fluid temp: -10 to 60 C, VALVE DBL NON PLUGIN BASE MT, VALVE, VFS5000 SOL VALVE 4/5 PORT, SI, VFS5000 BASE MT 3/4, 5.07063 lb

Fluid: air and inert gas, Operating pressure: 0.1MPa to 1.0MPa, Effective area (Cv): 2.2 to 5.7, Coil rated voltage: 100, 200 VAC 50/60Hz; 24VDC, Response time: 60 or less ms, Ambient/fluid temp: -10 to 60 C, VALVE DBL NON PLUGIN BASE MT, VALVE, VFS5000 SOL VALVE 4/5 PORT, 2I, VFS5000, 2.85344 lb

Fluid: air and inert gas, Operating pressure: 0.1MPa to 1.0MPa, Effective area (Cv): 2.2 to 5.7, Coil rated voltage: 100, 200 VAC 50/60Hz; 24VDC, Response time: 60 or less ms, Ambient/fluid temp: -10 to 60 C, VALVE DBL NON PLUGIN BASE MT, VALVE, VFS5000 SOL VALVE 4/5 PORT, SI, VFS5000 BASE MT 3/4, 6.44483 lb

Fluid: air and inert gas, Operating pressure: 0.1MPa to 1.0MPa, Effective area (Cv): 2.2 to 5.7, Coil rated voltage: 100, 200 VAC 50/60Hz; 24VDC, Response time: 60 or less ms, Ambient/fluid temp: -10 to 60 C, VALVE DBL NON PLUGIN BASE MT, VALVE, VFS5000 SOL VALVE 4/5 PORT, RI, VFS5000 BASE MT 1/2, 5.71312 lb

Port Port Shock Absorber Specifications 25 32 40 Applicable cylinder size (mm) RB1412 RB2015 RB2015 Shock absorber model Max. energy absorption (J) 19.6 58.8 58.8 Stroke absorption (mm) 12 15 15 Max. collision speed (mm/s) 1000 1000 1000 Max. operating frequency (cycle/min) 45 25 25 Extended 6.85 8.34 8.34 Spring force (N) Retracted 15.98 20.50 20.50 DOperating temperature range (C) 5 to 60

Theoretical Output CE1 (N) Operating pressure (MPa) Bore size (mm) Piston area (mm2) 0.2 98 161 251 CE2 0.8 0.7 343 563 879 0.6 294 483 754 0.5 245 402 628 0.4 196 322 502 0.3 147 241 377 Stroke Adjusting Unit Specifications 25 32 40 490 804 1256 392 ML2B 643 25 RB1007 5.9 7 1500 70 4.22 6.86 32 RB1412 19.6 12 1500 45 6.86 15.98 40 RB1412 19.6 12 1500 45 6.86 15.98 5 to 60 Applicable bore

11 13 16.5 4 7 6.5 10 14 34.5 40 50 63 100 120 148 162 16 20 20 14 44 12 16 16 44 47 50 54 64 78 14 19 19 6.5 6.8 7.5 27 32 39 25, 50, 75, 100, 125, 150 175, 200, 250, 300, 350 M8 11 12 39.5 107 14 44 M10 13.5 16.5 46 115 16.5 49 WA Bore size (mm) ML S T U VA OA OB OL P PA PB PW Q R VB MM NN st 25 25 < st 100 100 < st 200 200 < st 300 300 < st 350 38 47 55 30 40 50 13 9 14 18 104 44 60

Arm opening angle 30, 45, 60, 90, 105, 120, 135 Switch TURCK/P&F Both TURCK and P&F switches are available. Port thread NPT/G Reduces the effects of impact from unclamping the cylinder. Arm Variation Prevents the infiltration of spatter, dust and other contaminants.

Slider guide + Slide screw IX IY High rigidity IX H Low High rigidity achieved by the use of a hollow box type aluminum construction Low High Work load/Allowable moment IY W Model IX IY W H Sectional secondary moment Low noise (slide screw type) Slide screw + Slider guide: 47dB (LJ1S) Linear guide LJ1H10 LJ1H20 LJ1H30 LJ1S10 LJ1S20 LJ1S30 Slider guide 24.7 44.8 55 36 56.3 73.3 7 40 84 15 60