12.3 810 12.3 32, 40, 50, 63 124 AS3000-03 3/8 810 12.3 810 12.3 221 AS4000-02 1/4 1,670 25.5 1,670 25.5 40, 50, 63 80, 100 214 AS4000-03 3/8 1,670 25.5 1,670 25.5 205 AS4000-04 1/2 1,670 25.5 1,670 25.5 242 AS5000-02 1/4 2,840 44 2,840 44 40, 50, 63 80, 100 233 AS5000-03 3/8 4,270 66 4,270 66 224 AS5000-04 1/2 4,270 66 4,270 66 AS4000 Note) Flow rate values are measured at 0.5 Mpa and 20C
Note) Not applicable with the cases of standard dew point 20C (Nil), 15C (symbol H).
in the users equipment: 25 kW Power supply: 200 V 60 Hz Circulating fluid flow: 125 L/min@0.5 MPa External piping: Bypass piping + Heat load 21 Conditions 20 19 25 kW load Heat load fluctuation (0 kW 25 kW) 0 kW load 0 10 20 30 40 50 Time [Minute] Applicable to an ambient temperature of 20C.
Subsonic flow : Flow greater than the critical pressure ratio Standard condition : Air in a temperature state of 20C, absolute pressure 0.1 MPa (= 100 kPa = 1 bar), relative humidity 65%. It is stipulated by adding the (ANR) after the unit depicting air volume.
Low temperature operation 1) The valve can be used in an ambient temperature of between 10 to 20C.
JIS symbol 1/8, 5/32 3/16, 1/4 3/8 5/16 3/16, 1/4 1/4 3/16 1/4, 5/16 1/2 Inch sizes 3/8 5/32 Flow rate l/min (ANR) {Nl/min} 920 660 230 420 1390 290 460 1050 100 130 Controlled (Free) Effective area mm flow 14 10 3.5 6.5 21 4.5 7 16 2 1.5 1l/min=0.035SCFM 18mm2=1Cv Note 1) Flow rate values are at a pressure of 0.5MPa (72.5psi) and temperature of 20C (68F).
Cool from 30C (303 K) to 20C (293 K). Circulating fluid : Tap water Density : 1 x 103 kg/m3 Specific heat C : 4.2 x 103 J/(kgK) Refer to the information shown below for the typical physical property values by circulating fluid. Water bath Q = T x V x x C h x 60 x 1000 10 x 2 x 1 x 103 x 4.2 x 103 20C V = 15 x 60 x 1000 After 15 min, = 93.3 W cool 30C down to 20C.
AK ASS ASR ASF Flow Rate and Effective Area JIS Symbol ASD230FM ASD330FM ASD430FM Model 6, 8 8, 10 6 Metric size 4, 6 Tubing O.D. 1/8", 5/32" 3/16", 1/4" 1/4", 5/16" 3/8" 3/16", 1/4" Inch size Flow rate (l/min(ANR)) Controlled flow (Free flow) 7 12 38 0.1 0.6 0.2 Effective area (mm 2) Note) Flow rate values are measured at 0.5 MPa and 20C.
Specifications Grade 1 Note 1) Particulate generation grade Air/Nitrogen gas/Water (pure water) Note 2) Fluid 1MPa Note 3) Maximum operating pressure (20C) 100kPa Operating vacuum pressure Caution 3MPa Proof pressure (20C) 20C to 80C Ambient and fluid temperature Series KP is a line of special One-touch fittings for use in clean room blowing and washing lines.
E.g.: TEMP SP value: +20C, OFFSET value: +2C Circulating fluid discharge temp.: +20C, TEMP PV: +20C When OFF is selected If no mode is selected, temperature control is conducted to allow the discharge temperature of the circulating fluid to be TEMP SP value.
temperature Round lock nut With seal, Round lock nut, Nickel plated Option Weight (g) 181 106 64 29 10 6 3 Flow rate L/min (ANR) 105 230 460 920 1700 20 Controlled flow Free flow Sonic conductance dm 3/(sbar) 0.32 0.7 1.4 2.8 5.2 0.06 Critical pressure ratio Controlled flow 0.2 0.25 0.3 0.25 0.25 0.2 Free flow 0.4 0.2 0.3 0.2 0.3 0.4 Note 1) Flow rate values are measured at 0.5 MPa and 20C
(Inlet air pressure: 0.7 MPa, Inlet air temperature: 20C) HA How to Order AT ID 20 02 0 ID AMG ID400 Option B Bracket Z Adsorbent for low dew point Basic size AFF 20 30 40 60 Port size AM ID200 02 B 04 06 1 4 B 1 2 B 3 4 Nil Rc Thread type Misc.
Burst pressure Note) Min. bending radius (mm) 24 Burst pressure (MPa) Operating temperature Material 20C to 60C Nylon 12 Note) The value at temp. of 20C and with O.D. variable rate 10% max.
Burst pressure Burst pressure (MPa) Note) Min. bending radius (mm) 24 20C to 60C Operating temperature Material Nylon 12 Note) The value at temp. of 20C and with O.D. variable rate 10% max.
Note 3) The value at ambient temperature of 68F (20C) and when the rated voltage is applied. The value depends on the ambient environment. This is for reference. Note 1) Apparent power: The value at ambient temperature of 68F (20C) and when the rated voltage is applied.
After 15 minutes, cool 32C down to 20C.
TMH ASD AS Maximum return speed (mm/s) 100 200 300 Speed Controller Cylinder Solenoid valve Tubing Silencer AS-FE 6 ASD230FG CJ2 SYJ500 TU0604 1 m AN11001 KE 10 16 Cylinder size AS-FG AS-FG 20 ASD330FG CM2 SYJ700 TU0604 1 m AN11001 Cylinder size 25 AS-FP 32 Values at 0.5 MPa and 20C.
size 3.2, 4, 6 3.2, 4 6, 8, 10 8, 10 4 6 6 8 10 12 10, 12 Tubing O.D. 1/8", 5/32" 1/8" 3/16", 1/4" 1/4", 5/16" 3/8" 1/4" Inch size 5/32" 3/16" 5/16" 3/8" 1/2" 5/32" 5/16" 3/8" 3/16", 1/4" Controlled flow (Free flow) Flow rate (l/min (ANR)) 100 180 230 260 390 660 790 1580 1710 460 920 Effective area (mm 2) 1.5 2.7 3.5 4 6 7 10 12 14 24 26 Note) Flow rate values are measured at 0.5 MPa and 20C
8, 10 3.2, 4 4 6 6 8 10, 12 10 12 Tubing O.D. 1/8", 5/32" 3/16", 1/4" 3/16", 1/4" 5/16" 1/4", 5/16" 3/8" 1/8" 5/32" 1/4" Inch size 5/32" 3/16" 5/16" 3/8" 3/8" 1/2" Flow rate (l/min (ANR)) 100 230 180 260 390 460 660 790 920 1580 1710 Controlled flow (Free flow) 1.5 3.5 2.7 4 6 7 10 12 14 24 26 Effective area (mm2) Note) Flow rate values are at a pressure of 0.5 MPa and a temperature of 20C
53 External hold: 79 Internal hold: 90 MHKL2-16D 16 14 14.6 28.6 164 Double acting MRHQ MHKL2-20D 20 18 16 34 312 Auto switch MHKL2-25D 25 22 19 41 562 MHKL2-12S 90 105 20 9 11 12 9 Normally open Normally closed MHKL2-16S 165 28.6 14.6 14 16 17 MHKL2-20S 314 34 16 18 20 32 MHKL2-25S 565 41 19 22 25 53 L1 Single acting MHKL2-12C 105 20 9 11 12 11 L2 MHKL2-16C 166 28.6 14.6 14 16 22 MHKL2-20C