Magnet: Built-in, Mounting: Through Hole, Standard, Bore Size: 32mm, Water Resistant: None, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 20mm, Action: Double Acting, Rod End: Chamfered, Direct Mount Switch Groove: Direct Mount Switch Groove, Mounting Bolt: Shipped Together Only for Mounting B, Auto Switch: M9P--Solid State , Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire
Bore Size: 32mm, Port Thread: 20mm Bore: M Thread; 32-80mm Bore: Rc Thread, Stroke: 20mm, Action: Single Acting Spring Extend, Roller Material: Resin, Option: Locking Mechanism, Cancel Cap & Lever Detection Switch, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 1.0m Cord Length, M12-4 Pin Connector, Number: -
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 30, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: None, Operating Pressure(MPa): 0.2 to 1.0, Specification: Built-in
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: None, Operating Pressure(MPa): 0.2 to 1.0, Specification: Built-in
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: None, Operating Pressure(MPa): 0.2 to 1.0, Specification: Built-in
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: None, Operating Pressure(MPa): 0.2 to 1.0, Specification: Built-in
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 20, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: With fall prevention function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure(MPa): 0.25~1
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Air Cushion, Port thread type: G, Auto Switches: M9P, Lead Wire Length(m): 1, The number of the switches:
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Air Cushion, Port thread type: Rc, Auto Switches: M9P, Lead Wire Length(m): 1, The number of the switches:
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, End Locking: [Included] Presence, Cushion: Rubber Bumper on Both Ends, Port thread type: G, Auto Switches: M9P, Lead
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 250, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: Rubber cushion, Specification: Built-in magnet, Port thread type: Rc,
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: G, Auto Switches: M9P, Lead Wire Length
Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: G, Auto Switches: M9P, Lead Wire Length
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: M9P, Lead Wire
Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 350, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: M9P, Lead Wire
Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.07~1, Cushion: None, Specification: Built-in magnet, Support bracket:
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 40, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:
Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket: