1 to be closed while check ball !3 is open, and causing built-up oil outside to enter into the diaphragm interior. When exhaust pressure once again enters, operation of the piston and diaphragm causes the diaphragm to be compressed, and check ball !1 opens, causing the oil in the diaphragm interior to be discharged from discharge port !2.
D-R Note 3) Options for 2, 6, and 8 can not be specified at the same time. (Ex.) 68 Note 4) Symbols 9, D, J can not be specified at the same time. (Ex.) 9-D-J Note 5) For products with auto drain, either symbol D or J cannot be specified at the same time. 1 Indicate the required filtration rate after the symbol 1. Ex.)
The expected performance and safety assurance of the equipment will be the responsibility of the person who has determined its compatibility with the product regardless of any recommendation.
Note) Compared with AR25 type, its adjusting spring will only be changed for 0.2 MPa. It is not the product which does not allow the pressure more than 0.2 MPa.
This product cannot be used as a check regulator by installing it between solenoid valve and actuator. It can result in causing breakdown and malfunction. 2.
When in the exhaust position, the valve may be padlock secured, preventing accidental start-ups while personnel are cleaning or servicing equipment. The supply/exhaust status of the air flow can be verified at a glance in the indicating window.
The tightening torque should be 0.05 to 0.1 Nm. As a rule, it should be turned about 90 beyond the point at which tightening can be felt. Auto Switch Mounting Bracket Part No. Auto switch part no. D-M9(V) D-M9W(V) D-M9A(V) Auto switch mounting bracket part no.
External Pilot Adiabatic Space Caution Caution Pilot port 12(P1) and 10(P2) piping P1 and P2 piping should be as follows according to the model. There is a space between body and cover (: approximate 1 mm) for adiabatic effect.
Key can be removed at the on and off positions. 90 T.T.
Vacuum Flow ZH--X185 Series By supplying compressed air, RoHS Large blow and vacuum flow rate available A blow flow rate 4 times the supply air A vacuum flow rate 3 times the supply air A discharge flow rate 4 times the supply air can be generated. Contributes to reduction in flow consumption if discharge requires flow rate. A suction flow rate 3 times the supply air can be generated.
If the socket will be used again, first spread the hook outward.
Low power consumption: 4 W A long pipe can also be connected to the discharge port. It can be connected directly to a compressor. ADM200Model Air 1.0 MPa 1.5 MPa Fluid Max. operating pressure Proof pressure Ambient and fluid temperature Operating cycle 5 to 60C (No freezing) 1 cycle in a minute (Standard) 2 sec.
The unit is designed for use in food processing, pharmaceutical, brewing and breathing systems where odors must be removed.
Note 1) Manufactured upon receipt of order Note 2) The accessories should be mounted by user. JIS Symbol Accessory/Option Model Auto-drain Companion flange AT6C AT11C AT22C AT37C AT55C AT75C AT125C AT150C AT220C Precautions AD402-04 2BJIS10KFF Be sure to read before handling.
The front cylinder B (rod end) must be equal to 5" to allow the full stroke. Bore size (in) 1.50 2, 2.50 3.25, 4 3 positions can be obtained from a single cylinder. Twice the force is available for the extended stroke.
However, as mounting is not interchangeable, be sure to also change the piping base (sub-plate, manifold, etc.) when replacing an old V4000 series valve with one of the newer ones.
The old V4000 series catalog can be found here.
When replacing the product, be sure to confirm the thread type beforehand.
Example of valve series with an “E” prefix: EVT3, EVO3, EVK, EVP, EVF, EVS, EVN, EVY, etc.
For valves which had an “E” prefix, the thread type now needs to be indicated in the part number (e.g., symbol “F” for G thread).
A small amount of air will constantly leak because complete sealing cannot be achieved due to the construction of the product. The operating speed ranges from 80 to 100 mm/s to the high-speed range. Air cushions and shock absorbers are available.