5 6 6.5 6.5 7.5 D-A7/F7H D-A73C D-A80/A80H D-A80C D-A79W 12 11 10 12 12 13 13 14 14 16 15 17 D-F7/F7V D-J79/J79C D-F7W/F7WV D-J79W D-F7BAL/F7BAVL D-F7NTL/F79F 6 6 6 6.5 6.5 7 D-P4DWL 5 5 5 5 5.5 Since this is a guideline including hysteresis, not meant to be guaranteed.

Ground 4 +24V 2 +24V Shield 5 Shield N.C. 3 2 N.C. 2 N.C. 3 0V 1 0V 5 4 1 1 Internal circuit 8 0V 7 +24V 6 0V 5 +24V 4 TD 3 TD+ 2 RD 1 RD+ 8 0V 7 +24V 6 0V 5 +24V 4 TD 3 TD+ 2 RD 1 RD+ COM D COM A Common to IN side and OUT side Connect the communication cable with M12 connector to the M12 reverse communication connector.

5 6 7 8 9 1 0 1 11 2 1 31 41 5 7 8 9 10 11 Distance from cylinder shaft center Lo (cm) Distance from cylinder shaft center Lo (cm) CY3R20 CY3R40 500 200 300 100 200 50 100 20 30 40 50 30 10 Useable range 10 5 5 Useable range 1 0 1 2 3 4 5 6 1 7 8 9 10111213 0 1 2 3 4 5 6 7 8 9 1 0 1 11 2 1 31 41 5 Distance from cylinder shaft center Lo (cm) Distance from cylinder shaft center Lo (cm) CY3R25

10 15 0 5 10 15 20 25 0 5 10 15 20 Vertical L7 Work load [kg] Work load [kg] Work load [kg] 1000 1000 1000 800 800 800 600 600 600 Z 400 400 400 200 200 200 Mep m 0 0 0 0 5 10 15 0 5 10 15 20 25 0 5 10 15 20 L8 Work load [kg] Work load [kg] Work load [kg] Calculation of Guide Load Factor Mounting orientation 1.

2 4 1/8 One-touch fitting for 4 One-touch fitting for 6 One-touch fitting for 8 One-touch fitting for 5/32" One-touch fitting for 1/4" One-touch fitting for 5/16" 1/4 One-touch fitting for 8 One-touch fitting for 10 One-touch fitting for 5/16" One-touch fitting for 3/8" 1/4 3/8 One-touch fitting for 8 One-touch fitting for 10 One-touch fitting for 12 One-touch fitting for 5/16" One-touch

AK ASS ASR Flow Rate and Effective Area ASF Model AS121FM AS131FM AS221FM-01 AS231FM-01 AS221FM-02 AS231FM-02 3.2, 4, 6 6, 8 3.2, 4 8, 10 4 6 Metric size Tubing O.D. 1/8", 5/32", 3/16" 1/4" 3/16", 1/4" 5/16" 1/4", 5/16" 3/8" 1/8", 5/32" 5/32" 3/16" Inch size Air flow (l/min(ANR)) 7 12 38 Controlled flow JIS Symbol 0.1 Effective area (mm2) 0.2 0.6 Flow rate (l/min(ANR)) 230 180 460 260 390

For details, refer to page 9-15-40. 9-7-26 27 Series CNAW Cylinder with Lock Double Acting, Double Rod Construction #8 t #5 @7 e !6 !0 u @5 i !5 !1 o q $8 y $1 r #5 $6 #2 #7 #3 #4 B A CL CL1 MLGC #1 @3 !4 %0 !3 #9 @8 #6 $0 w #0 $5 $7 $3 $9 %1 $4 @1 @4 !8 @0 !7 !

sides of 1(P) port and exhaust air from both sides of 3 and 5(R) port.

0 u @5 i !5 !1 o q %0 y $3 r #3 #1 $1 #6 B A @3 !4 %2 !3 $0 @8 #7 $2 w #0 $7 $9 $5 %1 %3 $6 @1 @4 !8 @0 !7 !

Dimensions. 20 4-5. Construction . 25 5. Installation / Wiring . 26 5-1. Installation . 26 5-2. Electrical Wiring Diagram . 27 6. Setting . 29 6-1. Piston Rod Movement Direction (DIP Switch No. 1) . 30 6-2. Bore size (DIP Switch No. 2, No. 3, No. 4) . 30 6-3. Piston rod Movement at No Signal Operation . 31 6-4. Maximum Piston Rod Speed Setting (Rotary Switch) . 32 6-5.

Max. 141 Type *5 Non-magnetizing lock specification Lock unit Holding force [N] 20 39 47 78 157 72 108 216 75 113 225 Power consumption [W] *6 5 2.9 5 5 Power supply voltage [V] 24VDC10% *1 Speed changes according to the work load.

less 150 150 600mm stroke or less 100 100 50 50 0 0 0 1 2 3 4 5 0 1 2 3 4 5 Workload[kg] Workload[kg] 300 300 250 250 Overhang direction:L4[mm] L4 m Overhang direction:L4[mm] 600mm stroke 200 200 600mm stroke or less 500mm stroke or less 150 150 100 100 50 50 0 0 0 1 2 3 4 5 0 1 2 3 4 5 Workload[kg] Workload[kg] 500 500 600mm Wall Mounting 500mm or less Overhang direction:L5[mm] 400 400

5 5 5 Up to 500 Up to 500 Up to 600 Up to 600 Up to 800 Up to 800 19.5 27 32 32 37 37 12.2 14.2 19 19 23 27 4 4 5 9 12 14 15 10.5 11.5 17 6-7-20

IDF-TR1500-6 IDF-TR1500-7 IDF-TR1500-5 IDF-TR1500-6 IDF-TR1500-7 IDF-TR4000-5 IDF-TR4000-6 IDF-TR4000-7 IDF-TR4000-5 IDF-TR4000-6 IDF-TR4000-7 Part No.

North American type Made to Order Basic type Bore size (inch-Nominal) Stroke/Hundredths of an inch 6 1/4" Stroke/Inch 10 3/8" 15 5/8" 20 3/4" 25 1" 32 1-1/4" 40 1-1/2" 50 2" 63 2-1/2" Standard Stroke Bore size Standard stroke (inch) Max. stroke (inch) (mm) (inch-Nominal) 2, 3, 4, 5, 6, 8, 10 2, 3, 4, 5, 6, 8, 10 5, 10, 15, 20, 25, 30 5, 10, 15, 20, 25, 30, 40 5, 10, 15, 20, 25, 30, 40 5,

Band mounlina stvle 15, 30 45, 60 1 5 . 3 0 . 4 5 . 6 0 . 7 5 . 1 0 0 . 1 2 5 . 1 5 0 See Best Pneumatcs Vo ume 6 ior ava lab e alto swilches. ' See Besl Fneurnatcs Vo ume 6ior standard stroke lenqlhs 0n Port location on head cover Bore sizes: 2Omm, 25mm, 32mm, 4omm Many popular made-to-order options are available such as high temperature, rod boot, adjustable stroke, and many others.

Class Symbol PAF341S 12 x 10 10 x 8 19 x 16 12 x 10 25 x 22 19 x 16 PAF541S PAF341S PAF541S tubing size (mm) tubing size (inch ) SMC SMC SMC 4 4 5 5 6 6 1 2 1 2 1 2 4 4 5 5 6 6 A B A B A B 1/2" x 3/8" 3/8" x 1/4" Panel mount union U P 3/4" x 5/8" Union 1/2" x 3/8" 1" x 7/8" 3/4" x 5/8" SMC Note) Select the fitting after confirming the IN / OUT side fitting size and fitting type.

(PF2A7H: 0 to 50C) 2% F.S. (15 to 35C) 5% F.S. (0 to 50C) Monitor unit 2% F.S. (15 to 35C) 5% F.S. (0 to 50C) 2% F .S. (15 to 35C) 5% F .S. (0 to 50C) 2% F.S. (15 to 35C) 5% F.S. (0 to 50C) 0.5% F.S. (0 to 50C) 1% F.S. (Fluid: Dry air) Analog output: 3% F.S. 1% F .S. (PF2A70, PF2A7H) 2% F .S. (PF2A71) 1% F.S. (Fluid: Dry air) Analog output: 5% F.S. Monitor unit 0.1% F.S.