Left side parallel Symbol LEFS25 LEFS32 LEFS40 H 20 24 30 A 12 16 20 B 6 8 10 Symbol Type NZ Mounting type Z NY Mounting type Y NX Mounting type X NW Mounting type W NV Mounting type V NU Mounting type U NT Mounting type T NM1 Mounting type M1 NM2 Mounting type M2 * Refer to the applicable stroke table. w Size 25 32 40 Applicable Stroke Table : Standard Stroke [mm] Model 50 100 150 200 250
protocol MJ1 EX510-G MJ1 DN1 PR1 CC-Link DeviceNet PROFIBUS DP Power supply connector Specifications EX510-GMJ1 EX510-GDN1 EX510-GPR1 Model CC-Link Ver. 1.10 DeviceNet Release 2.0 PROFIBUS DP DP-V0 Protocol Version Note 1) Applicable system Communication connector Communication specification 9.6 k/19.2 k/45.45 k/ 93.75 k/187.5 k/500 k/ 1.5 M/3 M/6 M/12 Mbps 156 k/625 k/ 2.5 M/5 M/10 Mbps 125 k/250
Specifications FGH200 FGH300 Model FGH100 Number of built-in elements (element length) (mm) 1(125) 1(250) 1(500) Operating pressure MAX. 1 MPa Operating temperature MAX. 80C (Not above the boiling point) Each kind of fluid (See the table of applicable fluids on pages 63 and 64) Applicable fluid Port size (Rc) 3/8, 1/2, 3/4, 1 Stainless steel 316 (Electrolytic polishing) Housing Material PTFE
Temperature characteristics Current consumption (No load) Weight Note 3) Port size (Rc, NPT, G) Detection type Indicator light Operating pressure range Proof pressure Accumulated flow range Note 4) 0 to 50C 5% F.S. or less 1% F.S. or less 2% F.S. or less 3% F.S. or less (15 to 35C, based on 25C), 5% F.S. or less (0 to 50C, based on 25C) 160 mA or less 170 mA or less 290 g 150 mA or less 250
Applicable Stroke Table V: Standard Stroke [mm] Model 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1000 1100 1200 LEFS25 V V V V V V V V V V V V V V V V LEFS32 V V V V V V V V V V V V V V V V V V V V LEFS40 V V V V V V V V V V V V V V V V V V V V * Please consult with SMC for non-standard strokes as they are produced as special orders.
71000 1100 2500 4400 11000 18000 28000 36000 55000 1000 2000 4400 9000 14000 22000 36000 55000 0.5 0.5 0.5 0.5 0.5 0.5 0.75 1 1.25 2 2.5 3 Basic type, Flange type, Foot type Mounting Operating range Center of sphere Operating range Axial center 5 Semi-standard/Thread nominal size -5 to 60C JA20-8-100 JA25-10-150 JA32-10-100 JA40-12-125 JA40-12-150 JA40-12-175 JA50-16-150 JA63-16-200 JA80-20-250
Standard Strokes Bore size [mm] Standard stroke [mm] 1 20 25, 50, 75, 100, 125, 150, 200, 250, 300 25 32 40 1 Intermediate strokes not listed above are produced upon receipt of order. The minimum stroke is 25 mm. Mounting Brackets/Part No.
Example) LEY25DB-100 for the LEY25DB-100BMU-R16N1D-X5 Stroke Model 30 50 100 150 200 250 300 350 400 450 500 Manufacturable stroke range [mm] LEY25 15 to 400 LEY32 20 to 500 Please consult with SMC for non-standard strokes as they are produced as special orders. Conrm that the combination of the controller/driver and the actuator is correct.
N.O. 125 AC 250 AC 30 DC 125 DC 5 3 4 0.4 3 2 3 0.4 1.3 0.8 2.5 1.5 0.7 0.5 1.5 1 3 0.05 2 0.05 0.1 0.1 Insulation resistance: 100 M or more at 500 VDC by megameter Voltage resistance: 1500 VAC, Hz for 1 min.
Mounting Foot, Rod flange, Head flange, Single clevis, Double clevis Rod end configuration Rod end male thread, Rod end female thread Allowable rotational torque 0.25 Nm 0.55 Nm 1.25 Nm 2.0 Nm Rod non-rotating accuracy 0.5 1 0.8 Standard Stroke (mm) Size Standard stroke (mm) Maximum manufacturable stroke 25, 32, 40 50, 63 5, 10, 15, 20, 25, 30, 35, 40, 45, 50 75, 100, 125, 150, 175, 200, 250
each type) 0.7MPa Symbol Maximum operating pressure Extension locking Retraction locking 245 403 629 982 M5 x 0.8 Rc, NPT, 1/8 Unlocking port connection size W Holding force N (maximum static load) Non-rotating Rod Accuracy W 25 1 32 0.8 40 0.5 50 0.5 Size Non-rotating rod accuracy Standard Strokes Size Standard stroke (mm) 5, 10, 15, 20, 25, 30, 35, 40, 45, 50 75, 100, 125, 150, 175, 200, 250
Battery life 12 months continuous operation (Without backlighting, temperature conditions: at 25C) Response speed 250 ms Display accuracy 2% F.S. or less (Temperatue conditions: at 25C) Repeatability 1% F.S. or less (Temperatue conditions: at 25C) Temperature characteristics 3% F.S. or less (0 to 50C with 25C standard) Piping port M5 x 0.8 0 to 50C (With no condensation) Ambient operating
Metric size 2 3.2 3.2 4 4 6 6 8 10 12 Inch size 1/8" 1/8" 5/32" 5/32" 1/4" 1/4" 5/16" 3/8" 0.8 Fluid Air, Nitrogen 0.6 Operating pressure 100 kPa to 1.0 MPa (at 20C) Flow rate (Positive pressure) [L/min] *1 15 45 50 80 100 200 250 450 550 650 0.4 Flow rate (Vacuum pressure) [L/min] 2 5 7 10 10 20 30 70 80 100 0.2 Proof pressure [MPa] 1.5 (at 20C) Operating and ambient temperature range
10 to 60C (No freezing or condensation)Operating/Stored: 35 to 85% RH (No condensation)250 VAC for 1 minute between live parts and case2 M or more between live parts and case (at 50 VDC Mega)10 to 150 Hz at whichever is smaller of 1.5 mm amplitude or 20 m/s2 acceleration, in X, Y, Z directions, for 2 hours each (De-energized)100 m/s2 in X, Y, Z directions, 3 times each (De-energized)?
10 to 60C (No freezing or condensation)Operating/Stored: 35 to 85% RH (No condensation)250 VAC for 1 minute between live parts and case2 M or more between live parts and case (at 50 VDC Mega)10 to 150 Hz at whichever is smaller of 1.5 mm amplitude or 20 m/s2 acceleration, in X, Y, Z directions, for 2 hours each (De-energized)100 m/s2 in X, Y, Z directions, 3 times each (De-energized)?
10 to 60C (No freezing or condensation)Operating/Stored: 35 to 85% RH (No condensation)250 VAC for 1 minute between live parts and case2 M or more between live parts and case (at 50 VDC Mega)10 to 150 Hz at whichever is smaller of 1.5 mm amplitude or 20 m/s2 acceleration, in X, Y, Z directions, for 2 hours each (De-energized)100 m/s2 in X, Y, Z directions, 3 times each (De-energized)?
40, 50, 63, Standard stroke (mm): 50, 75, 100, 125, 150, 200, 250, 300, 350, 400, 450, 500, Rc, NPT or G port threads, Clean series, AME NO SIZE RAPART, AIRLINE EQUIPMENT, AME SUPER MIST SEPARATOR, 21, AME NO SIZE RAPART, 2.40722 lb
10 to 60C (No freezing or condensation)Operating/Stored: 35 to 85% RH (No condensation)250 VAC for 1 minute between live parts and case2 M or more between live parts and case (at 50 VDC Mega)10 to 150 Hz at whichever is smaller of 1.5 mm amplitude or 20 m/s2 acceleration, in X, Y, Z directions, for 2 hours each (De-energized)100 m/s2 in X, Y, Z directions, 3 times each (De-energized)?
10 to 60C (No freezing or condensation)Operating/Stored: 35 to 85% RH (No condensation)250 VAC for 1 minute between live parts and case2 M or more between live parts and case (at 50 VDC Mega)10 to 150 Hz at whichever is smaller of 1.5 mm amplitude or 20 m/s2 acceleration, in X, Y, Z directions, for 2 hours each (De-energized)100 m/s2 in X, Y, Z directions, 3 times each (De-energized)?
10 to 60C (No freezing or condensation)Operating/Stored: 35 to 85% RH (No condensation)250 VAC for 1 minute between live parts and case2 M or more between live parts and case (at 50 VDC Mega)10 to 150 Hz at whichever is smaller of 1.5 mm amplitude or 20 m/s2 acceleration, in X, Y, Z directions, for 2 hours each (De-energized)100 m/s2 in X, Y, Z directions, 3 times each (De-energized)?