(full span), GAUGE, AIRLINE EQUIPMENT, AR REGULATOR, 22, AR NO SIZE RATKIT/ACCESSORY, .17215 lb
Pressure gauge with built-in switch, Equipped with a light for verifying operation, Equipped with a limit indicator, Optional cover ring assembly and 3m lead wire length, Pressure range 0 to 1.0 MPa, GAUGE W/LIGHT EMITTING DIODE, AIRLINE EQUIPMENT, AR REGULATOR, 22, AR NO SIZE RATKIT/ACCESSORY, .43241 lb
Pressure gauge with built-in switch, Equipped with a light for verifying operation, Equipped with a limit indicator, Optional cover ring assembly and 3m lead wire length, Pressure range 0 to 1.0 MPa, GAUGE, PANEL MOUNT, AIRLINE EQUIPMENT, AR REGULATOR, 22, AR NO SIZE RATKIT/ACCESSORY, .54266 lb
Pressure gauge with built-in switch, Equipped with a light for verifying operation, Equipped with a limit indicator, Optional cover ring assembly and 3m lead wire length, Pressure range 0 to 1.0 MPa, GUAGE, AIRLINE EQUIPMENT, AR REGULATOR, 22, AR NO SIZE RATKIT/ACCESSORY, .33495 lb, ModelPort sizeMaterialSensor cableMassWith sensor cableWithout sensor cable01R 1/8M5 x 0.8Case: C3604
filter to be done easily and without tools.Compact type thermal-chiller , Single phase, 100/115VAC, Cooling method: air-cooled or water-cooled , Self diagnosis and check display for easy maintenance , Functions: timer operation, low tank level detecting, power failure auto-restart, anti-freezing, THERMO CHILLER, WATER COOLED, OTHERS, HRS THERMO-CHILLERS, 22, HRS - NO SIZE RATING, 94.79877
allowing mounting and removal of the HRS filter to be done easily and without tools.Compact type thermal-chiller , Single phase, 100/115VAC, Cooling method: air-cooled or water-cooled , Self diagnosis and check display for easy maintenance , Functions: timer operation, low tank level detecting, power failure auto-restart, anti-freezing, HRS - NO SIZE RATING, OTHERS, HRS THERMO-CHILLERS, 22
allowing mounting and removal of the HRS filter to be done easily and without tools.Compact type thermal-chiller , Single phase, 100/115VAC, Cooling method: air-cooled or water-cooled , Self diagnosis and check display for easy maintenance , Functions: timer operation, low tank level detecting, power failure auto-restart, anti-freezing, POWER SUPPLY CABLE, OTHERS, HRS THERMO-CHILLERS, 22
mounting and removal of the HRS filter to be done easily and without tools.Compact type thermal-chiller , Single phase, 100/115VAC, Cooling method: air-cooled or water-cooled , Self diagnosis and check display for easy maintenance , Functions: timer operation, low tank level detecting, power failure auto-restart, anti-freezing, OP PANEL REMOTE CONTROL FOR, OTHERS, HRS THERMO-CHILLERS, 22
mounting and removal of the HRS filter to be done easily and without tools.Compact type thermal-chiller , Single phase, 100/115VAC, Cooling method: air-cooled or water-cooled , Self diagnosis and check display for easy maintenance , Functions: timer operation, low tank level detecting, power failure auto-restart, anti-freezing, OP PANEL REMOTE CONTROL FOR, OTHERS, HRS THERMO-CHILLERS, 22
allowing mounting and removal of the HRS filter to be done easily and without tools.Compact type thermal-chiller , Single phase, 100/115VAC, Cooling method: air-cooled or water-cooled , Self diagnosis and check display for easy maintenance , Functions: timer operation, low tank level detecting, power failure auto-restart, anti-freezing, HRS - NO SIZE RATING, OTHERS, HRS THERMO-CHILLERS, 22
NPT THD CONVERSON FITTING SET, OTHERS, HRS THERMO-CHILLERS, 22, HRS - NO SIZE RATING, 2.33689 lb
NPT THD CONVERSON FITTING SET, OTHERS, HRS THERMO-CHILLERS, 22, HRS - NO SIZE RATING, 2.06352 lb
allowing mounting and removal of the HRS filter to be done easily and without tools.Compact type thermal-chiller , Single phase, 100/115VAC, Cooling method: air-cooled or water-cooled , Self diagnosis and check display for easy maintenance , Functions: timer operation, low tank level detecting, power failure auto-restart, anti-freezing, FILTER SCREEN KIT, OTHERS, HRS THERMO-CHILLERS, 22
mounting and removal of the HRS filter to be done easily and without tools.Compact type thermal-chiller , Single phase, 100/115VAC, Cooling method: air-cooled or water-cooled , Self diagnosis and check display for easy maintenance , Functions: timer operation, low tank level detecting, power failure auto-restart, anti-freezing, CASTER ADJUSTER-FOOT KIT, OTHERS, HRS THERMO-CHILLERS, 22
Membrane air dryer series, Single unit style, 10 sizes available, Port sizes: 1/8" to 1/2", AIR DRYER, MEMBRANE(200/22)-15, OTHERS, IDG MEMBRANE AIR DRYER, IDG 3/8 MEMBRANE AIR DRYER, 1.45505 lb, ModelRange of operating conditionsStandard perfor- manceStandard performance conditionsDew point indicator purge air flow ratePort size (Nominal size B)Weight (kg) (With bracket)FluidInlet
Manifold for ISA2 air catch sensor, Available with or without control unit, 6 stations maximum, Options: bracket, DIN rail, MANIFOLD FOR ISA2, W/CTL UNIT, INSTRUMENTATION, ISA2 AIR CATCH SENSOR, 22, ISA2 NO SIZE KIT/ACCESSORY, 1.68009 lb
Manifold for ISA2 air catch sensor, Available with or without control unit, 6 stations maximum, Options: bracket, DIN rail, MANIFOLD FOR ISA2,W/O CTL UNIT, INSTRUMENTATION, ISA2 AIR CATCH SENSOR, 22, ISA2 NO SIZE KIT/ACCESSORY, .83707 lb
BAR NOZZLE, 400M, OTHERS, IZS/IZF IONIZER, 22, IZSE30 NO SIZE RATING
Part Number Description: U-CLAMP PANEL MOUNT GAUGE Product Line: E Product Line Description: AIRLINE EQUIPMENT Family Code: 115 Family Description: AR REGULATOR Class Code: 22 Part Code: 2 Reference Code: B PDF Documentation: Click here to report information errorImage shown may not match exact part number
Series VX21/22/23, is a direct operated 2 port solenoid valve for air, gas, vacuum, water, steam and oil. Proper selection of body and sealing materials permits application of a wide variety of fluids. Application can be matched by simply choosing body materials (brass, stainless steel), seal materials (NBR, EPR, FPM, PTFE) and the solenoid coil (class B, class H).