PVQ series, compact proportional solenoid valve, was designed by SMC with a direct poppet construction. ?This construction?enables low leakage, while de-energized.? PVQ series has been used in applications such as air blow, flow control, hand piece control for dental unit and other respiratory equipment,?as well as, cooling for laser machinery etc. Direct operated poppet valve construction
N.C. valve type, class B coil insulation, Power consumption 2.5w, IP65 enclosure, Seal: NBR (low concentration ozone resistant type: FKM), DIRECTIONAL 2 WAY SOLENOID VALVE, 2 PORT VALVE, 0.0667 lb
Stations: 06 (Stations), Wiring: F (D-sub Connector), Manifold Options: without Option, Exhaust: H (High Noise Reduction Silencer Exhaust), Pressure Switch for Vacuum/Pressure Sensor: H (Digital Pressure Switch for Vacuum, -100 to 100, PNP 2 Outputs, with Unit Selection Function), Leadwire: Y (2m Switch/Sensor Only), Unit Options: without Option, 1st Nominal Nozzle Size: 3 (ø1.2), 1st Selection
Stations: 04 (Stations), Wiring: F (D-sub Connector), Manifold Options: L (Manifold Indivdual Supply Specification), Exhaust: H (High Noise Reduction Silencer Exhaust), Pressure Switch for Vacuum/Pressure Sensor: H (Digital Pressure Switch for Vacuum, -100 to 100, PNP 2 Outputs, with Unit Selection Function), Leadwire: without Leadwire, Unit Options: without Option, 1st Nominal Nozzle Size
Body/Exhaust Type: H (For Manifold - High-noise Reduction Silencer Exhaust), Nominal Nozzle Size: 12 (ø1.2), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: H (Digital Pressure Switch for Vacuum / -100 to 100 kPa / PNP 2 Outputs), Connector: C [Common Wiring (plug-in) - w/o Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch
Body/Exhaust Type: H (For Manifold - High-noise Reduction Silencer Exhaust), Nominal Nozzle Size: 15 (ø1.5), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: H (Digital Pressure Switch for Vacuum / -100 to 100 kPa / PNP 2 Outputs), Connector: C1 [Common Wiring (plug-in) - w/o Lead Wire with Connector - w/o Lead Wire with Connector for Pressure Switch
Model: 32, Orifice: 2 (2.2mm), Style: 4 (COM, Single Unit), Option: H (Stainless Steel, Seals: FKM, Class B), Suffix: Standard, Port Size: 02 (1/4), Thread: Rc, Voltage: 5 (24VDC), Electrical Entry: D (DIN Terminal), Surge Suppressor: Non, Rectifier: None (for DC or AC Class H Coil)
Body/Exhaust Type: H (For Manifold - High-noise Reduction Silencer Exhaust), Nominal Nozzle Size: 07 (ø0.7), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: H (Digital Pressure Switch for Vacuum / -100 to 100 kPa / PNP 2 Outputs), Connector: C1 [Common Wiring (plug-in) - w/o Lead Wire with Connector - w/o Lead Wire with Connector for Pressure Switch
Body/Exhaust Type: H (For Manifold - High-noise Reduction Silencer Exhaust), Nominal Nozzle Size: 07 (ø0.7), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: H (Digital Pressure Switch for Vacuum / -100 to 100 kPa / PNP 2 Outputs), Connector: L3 [L-type Plug Connector - w/o Lead Wire with Connector - w/o Lead Wire with Connector for Pressure Switch
Model: 32, Orifice: 2 (2.2mm), Style: 1 (N.C., Manifold), Option: D (For Oil -- Seals: FKM, Body: Brass, Coil: Copper, Class H), Suffix: Standard, Voltage: 7 (240VAC 50/60HZ), Electrical Entry: T (Conduit Terminal), Surge Suppressor: S (Surge Suppressor), Rectifier: None (for DC or AC Class H Coil)
SI Unit: H (NKE Uni-wire H System), Valve Stations: 6 Stations, Mounting Position: D (D Side 2~10 Stations), Pilot Type: Standard Internal Pilot, A, B Port Size: C6 (ø6 One-touch Fitting)
Part Number Description: BRACKET-HANGING (H) Product Line: E Product Line Description: AIRLINE EQUIPMENT Family Code: 100 Family Description: AC FRL COMBO Class Code: 22 Part Code: 2 Reference Code: B Click here to report information errorImage shown may not match exact part number, BRACKET-HANGING ( H ), AIRLINE EQUIPMENT, AC FRL COMBO, 22, AC NO SIZE RATING ACCESSORY
Body/Exhaust Type: H (For Manifold - High-noise Reduction Silencer Exhaust), Nominal Nozzle Size: 15 (ø1.5), Supply Valve and Release Valve: J (N.C. / None), Rated Voltage: 5 (24 VDC), Vacuum Sensor: H (Digital Pressure Switch for Vacuum / -100 to 100 kPa / PNP 2 Outputs), Connector: L [L-type Plug Connector - w/ Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor
Body/Exhaust Type: H (For Manifold - High-noise Reduction Silencer Exhaust), Nominal Nozzle Size: 15 (ø1.5), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: H (Digital Pressure Switch for Vacuum / -100 to 100 kPa / PNP 2 Outputs), Connector: C [Common Wiring (plug-in) - w/o Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch
Body/Exhaust Type: H (For Manifold - High-noise Reduction Silencer Exhaust), Nominal Nozzle Size: 15 (ø1.5), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: H (Digital Pressure Switch for Vacuum / -100 to 100 kPa / PNP 2 Outputs), Connector: C [Common Wiring (plug-in) - w/o Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch
Stations: 05 (Stations), Wiring: F (D-sub Connector), Manifold Options: without Option, Exhaust: H (High Noise Reduction Silencer Exhaust), Pressure Switch for Vacuum/Pressure Sensor: H (Digital Pressure Switch for Vacuum, -100 to 100, PNP 2 Outputs, with Unit Selection Function), Leadwire: without Leadwire, Unit Options: without Option, 1st Nominal Nozzle Size: 4 (ø1.5), 1st Selection Supply
Stations: 05 (Stations), Wiring: F (D-sub Connector), Manifold Options: without Option, Exhaust: H (High Noise Reduction Silencer Exhaust), Pressure Switch for Vacuum/Pressure Sensor: H (Digital Pressure Switch for Vacuum, -100 to 100, PNP 2 Outputs, with Unit Selection Function), Leadwire: without Leadwire, Unit Options: without Option, 1st Nominal Nozzle Size: 4 (ø1.5), 1st Selection Supply
Stations: 01 (Station), Wiring: F (D-sub Connector), Manifold Options: without Option, Exhaust: H (High Noise Reduction Silencer Exhaust), Pressure Switch for Vacuum/Pressure Sensor: H (Digital Pressure Switch for Vacuum, -100 to 100, PNP 2 Outputs, with Unit Selection Function), Leadwire: Y (2m Switch/Sensor Only), Unit Options: E (Vacuum Break Flow Adjusting Needle, Screwdriver Operation
SMC's updated VXD series for heated water (up to 99°C) is a pilot operated, 2 port solenoid valve. Standard EPDM seal material and Class H coil insulation to suit the high fluid temperature application. Available in brass and stainless steel.