Fluid: air and inert gas, Operating pressure: 0.1MPa to 1.0MPa, Effective area (Cv): 1.7 to 3.6, Coil rated voltage: 100, 200 VAC 50/60Hz; 24VDC, Response time: 55 or less ms, Ambient/fluid temp: -10 to 60 C, VALVE SGL PLUG-IN BASE MOUNT, VALVE, VFS4000 SOL VALVE 4/5 PORT, QD, VFS4000 BASE MT 3/8, .00000 lb
Fluid: air and inert gas, Operating pressure: 0.1MPa to 1.0MPa, Effective area (Cv): 1.7 to 3.6, Coil rated voltage: 100, 200 VAC 50/60Hz; 24VDC, Response time: 55 or less ms, Ambient/fluid temp: -10 to 60 C, VALVE SGL NON PLUG-IN BASE MT, VALVE, VFS4000 SOL VALVE 4/5 PORT, 2D, VFS4000, 1.38891 lb
Fluid: air and inert gas, Operating pressure: 0.1MPa to 1.0MPa, Effective area (Cv): 1.7 to 3.6, Coil rated voltage: 100, 200 VAC 50/60Hz; 24VDC, Response time: 55 or less ms, Ambient/fluid temp: -10 to 60 C, VALVE DBL NON PLUG-IN BASE MT, VALVE, VFS4000 SOL VALVE 4/5 PORT, 2Q, VFS4000, 3.60087 lb
Japanese N ...North American No Of Needle Revolutions 10 Turns / 8 Turns (AS1001F) Applicable Tube Material Nylon, Soft Nylon, Polyurethane A P P L I C A B L E T U B E OD B O D Y S I Z E mm 23 32 04 4 06 6 08 8 10 10 12 12 Inch 01 1/8 03 5/32 05 3/16 07 1/4 09 5/16 11 3/8 13 1/2 100 ...M5 (04, 06) 200 ...1/8 (04, 06) 205 ...1/4 (06, 08) 300 ...3/8 (06, 08, 10, 12) 400 ...1/2 (10, 12) W I
Symbol 46 42.5 Outside diameter Indicator light Max. display pressure Symbol 10 1.0 Unit: MPa Without indicator light Nil L2 Neon light (100 VAC/220 VAC) Attachment (Cover ring assembly) L5 LED/24 VDC Connection thread Without cover ring assembly Symbol Specifications Symbol Size Nil 01 R 1 8 Clear cover has no protrusion. (Clear cover is irremovable.)
If it must be installed in an environment with poor noise conditions, eliminate the power supply noise by using a line filter, Z-wrap, or a spark killler on the 100 V power supply or signal source line. The length of the power suply and signal lines must be kept as short as possible.
N.C. 125 AC 250 AC 30 DC 125 DC 1.3 0.8 2.5 1.5 0.7 0.5 1.5 1 3 0.05 2 0.05 Insulation resistance: 100 M or more at 500 VDC by megameter Voltage resistance: 1500 VAC, Hz for 1 min.
Display the error code on LCD. 3 1/2 digits (5 mm-size numerals) Overcurrent, Overpressure, Data error Pressure during 0 clear 0 to 60C (No dewing) 1000 Vp-p, Pulse width 1 s, Rise time 1 ns Between external terminals and housing 1000 VAC, 50/60 Hz for 1 min.
directions 3 times each (De-energized) In a temperature range of 0 to 50C, 2% F .S. or less of pressure measured at 25C Vibration resistance Impact resistance Temperature characteristics 01: R 1/8, M5 x 0.8, T1: NPT1/8, M5 x 0.8, W1: Rc 1/8 C4: With 4 One-touch fitting, C6: With 6 One-touch fitting, M5: M5 female threads 5-wire oil resistant heavy-duty cord (0.15 mm2) 01/T1 types approx. 60
. -20 1.08 -10 0 10 30 40 50 60 Air temperature (C) 1.06 1.04 1.02 0.98 0.97 0.95 0.94 Coefficient for compensation ambient temperature is within valve specification range. Maintenance 1 Maintenance procedures are shown in operation manual.
Indicator light and surge voltage suppressor Coil voltage None With surge voltage suppressor With indicator light and surge voltage suppressor S Z 100V AC(50/60 Hz) 200V AC 110V AC 24V DC 12V DC Others voltages 1 2 3 5 6 Note) Coil voltage 100V AC: With surge voltage suppressor. Note) "YOZ" is not available. 9(1) Note 1) Contact SMC for other voltages.
Current consumption [Power supply voltage] 1.5 V Power supply voltage for sensor 40 mA maximum (100 mA maximum for the total power supply current when 4 sensors are input.)
Display the error code on LCD. 3 1/2 digits (5 mm-size numerals) Overcurrent, Overpressure, Data error Pressure during 0 clear 0 to 60C (No dewing) 1000 Vp-p, Pulse width 1 s, Rise time 1 ns 1000 VAC in 50/60 Hz for 1 minute between live parts and case 2 M or more (at 500 VDC by megameter) betweeen live parts and case 10 to 500 Hz Pulse width 1.5 mm or acceleration 98 m/s2 (at the smaller
(Example) SYJ3120-5M-M3 VJ3000-13-1 DC AC (50/60 Hz) 5 6 V S R 1 2 3 4 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC 100 VAC 200 VAC 110 VAC [115 VAC] 220 VAC [230 VAC] For type W, DC voltage is only available.
AS1201F-M5, AS1211F-M5 AS2201F-01, AS2211F-01 AS2201F-02, AS2211F-02 Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa 100 Flow rate (L/min (ANR)) Flow rate (L/min (ANR)) Flow rate (L/min (ANR)) 80 60 40 20 0 0 2 4 6 8 Number of needle rotations Number of needle rotations Number of needle rotations AS3201F, AS3211F AS4201F, AS4211F Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa Flow rate (
AS2000-N02-X800 NPT1/4 12 50 26 20 62 58 21 170 AS3000-N03-X800 NPT3/8 12 60 26 17 71 64 24 250 AS4000-N04-X800 NPT1/2 17 81 36 22 92 83 30 480 Note) Reference dimensions
Grease pack (10 g) 1 pc. 84.8 IN 25 42 59 CQSY16-PS 12 6 113 OUT 34 57 79 CQSY20-PS REA 151 IN 45 75 106 CQSY25-PS 16 8 201 OUT 60 101 141 When only grease for maintenance is necessary, please order by the following part numbers.
type Nil Rc V V V V N NPT V V V V F G V V V V + 02 1/4 V 03 3/8 V 04 1/2 V 06 3/4 V 10 1 V + e Port size 1(P), 2(A) a Mounting Nil Without mounting option V V V V B With bracket V V V V + Option b Pressure gauge Nil Without pressure gauge V V V V G Round type pressure gauge (with limit indicator) V V V V + r c Silencer Nil Without silencer V V V V S Silencer (Built-in) V V V V + 1 100
Accessory Dimensions 25.7 64 16 54 0.2 5 70 0.2 5 PWR (V) 40 BUS PWR 80 OUTPUT INPUT Cover view 2 x M4 Mounting hole OUTPUT INPUT COM D 60 COM C COM B COM A 1702
S Couplers Series KK Specifications K M Fluid Air, Water KK2: 100 kPa to 1 MPa KK3: 90 kPa to 1 MPa KK4/6: 0 to 1 MPa H Operating pressure range Note) KK Proof pressure 1.5 MPa Air: 5 to 60C Water: 5 to 40C (No freezing) Series KK2 D Ambient and fluid temperature MS Plating, Sealant Electroless nickel plated (copper-free and fluorine-free application), With male thread sealant LQ Note) Do