Thomas Oil-less Linear Diaphragm Compressor / Vacuum Pump, 230/50/60/1 Flow Rate: 43 LPM , 43 LPM, Max Pressure: 2.9 PSIG / 80 in H20 / 200 mbar , 2.9 PSIG / 80 in H20 / 200 mbar, Max Vacuum: 5.9 in HgV / -200 mbar , 5.9 in HgV / -200 mbar, Voltage (60 Hz): 230, Voltage (50 Hz): 230, Frequency (Hz): 50 / 60, Phase: 1-phase, Item Dimensions: Length: 8.15

Thomas Oil-less Linear Diaphragm Compressor / Vacuum Pump, 230/50/60/1 Flow Rate: 43 LPM , 43 LPM, Max Pressure: 2.9 PSIG / 80 in H20 / 200 mbar , 2.9 PSIG / 80 in H20 / 200 mbar, Max Vacuum: 5.9 in HgV / -200 mbar , 5.9 in HgV / -200 mbar, Voltage (60 Hz): 230, Voltage (50 Hz): 230, Frequency (Hz): 50 / 60, Phase: 1-phase, Item Dimensions: Length: 8.15

/LXSH2SB 200 200 200 Transfer load 4.5kg Ultimate speed (mm/s) Ultimate speed (mm/s) Ultimate speed (mm/s) Transfer load 4kg 3kg Transfer load 2kg 2kg 100 100 100 1.5kg 0kg 0kg 0kg 0 0.05 0.1 0 0.05 0.1 0 0.1 0.2 Time (s) Time (s) Time (s) Acceleration Time Guide/Slide Screw Specification (Vertical) LXPB5SA/LXSH5SA LXPB2SA/LXSH2SA Caution 100 100 Transfer loads should not exceed each model's

Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: N (NPT, w/Rc-NPT Conversion Fitting), Power Supply: 20 (3-phase 200 VAC, 50Hz; 3-phase 200 to 230 VAC, 60Hz), Option: B (w/Earth Leakage Breaker)

Cooling Method: W (Water-cooled Refrigeration), Pipe Thread: N (NPT, w/Rc-NPT Conversion Fitting), Power Supply: 20 (3-phase 200 VAC, 50Hz; 3-phase 200 to 230 VAC, 60Hz), Option: B (w/Earth Leakage Breaker)

Cooling Method: W (Water-cooled Refrigeration), Pipe Thread: Rc, Power Supply: 20 (3-phase 200 VAC, 50Hz; 3-phase 200 to 230 VAC, 60Hz), Option: JS (w/Automatic Fluid Fill Function + Conforming to CE/UL Standards)

Cooling Method: W (Water-cooled Refrigeration), Pipe Thread: Rc, Power Supply: 20 (3-phase 200 VAC, 50Hz; 3-phase 200 to 230 VAC, 60Hz), Option: MS (Applicable to Deionized Water Piping + Conforming to CE/UL Standards)

Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: Rc, Power Supply: 20 (3-phase 200 VAC, 50Hz; 3-phase 200 to 230 VAC, 60Hz), Option: MS (Applicable to Deionized Water Piping + Conforming to CE/UL Standards)

Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: F (G, w/Rc-G Conversion Fitting), Power Supply: 20 (3-phase 200 VAC, 50Hz; 3-phase 200 to 230 VAC, 60Hz), Option: B (w/Earth Leakage Breaker)

Magnet: D (Built-in), Mounting: A (Both Ends Tapped), Overall Length: Standard, Bore Size: 200 (2"), Stroke: 200 (2"), Body Option: Standard (Rod End Female Thread), Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal

Magnet: D (Built-in), Mounting: B (Through Hole), Overall Length: Standard, Bore Size: 200 (2"), Stroke: 200 (2"), Body Option: Standard (Rod End Female Thread), Auto Switch: M9PV--Solid State, Gen. Purpose, 3 Wire PNP, Vertical

Magnet: D (Built-in), Mounting: C (Rear Clevis), Overall Length: Standard, Bore Size: 200 (2"), Stroke: 200 (2"), Body Option: Standard (Rod End Female Thread), Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal

Magnet: D (Built-in), Mounting: B (Through Hole), Overall Length: Z (Super Compact), Bore Size: 200 (2"), Stroke: 200 (2"), Body Option: C (Rubber Bumper), Auto Switch: No Switch, Lead Wire or Prewired Connector: M (1m)